A wearable electrochemical sensor for the real-time measurement of sweat sodium concentration

被引:212
|
作者
Schazmann, Benjamin [1 ]
Morris, Deirdre [2 ]
Slater, Collor [2 ]
Beirne, Stephen [2 ]
Fay, Cormac [2 ]
Reuveny, Ronen [3 ]
Moyna, Niall [3 ]
Diamond, Dermot [2 ]
机构
[1] Dublin Inst Technol, Sch Chem & Pharmaceut Sci, Dublin 8, Ireland
[2] Dublin City Univ, NCSR, Dublin 9, Ireland
[3] Dublin City Univ, Sch Hlth & Human Performance, Dublin 9, Ireland
基金
爱尔兰科学基金会;
关键词
ION-SELECTIVE ELECTRODES; POLYMERIC MEMBRANE ELECTRODES; CYSTIC-FIBROSIS; SOLID-CONTACT; FLUID REPLACEMENT; EXERCISE; CHLORIDE; WATER; ELECTROLYTES; CALIXARENES;
D O I
10.1039/b9ay00184k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report a new method for the real-time quantitative analysis of sodium in human sweat, consolidating sweat collection and analysis in a single, integrated, wearable platform. This temporal data opens up new possibilities in the study of human physiology, broadly applicable from assessing high performance athletes to monitoring Cystic Fibrosis (CF) sufferers. Our compact Sodium Sensor Belt (SSB) consists of a sodium selective Ion Selective Electrode (ISE) integrated into a platform that can be interfaced with the human body during exercise. No skin cleaning regime or sweat storage technology is required as the sweat is continually wicked from the skin to a sensing surface and from there to a storage area via a fabric pump. Our results suggest that after an initial equilibration period, a steady-state sodium plateau concentration was reached. Atomic Absorption Spectroscopy (AAS) was used as a reference method, and this has confirmed the accuracy of the new continuous monitoring approach. The steady-state concentrations observed were found to fall within ranges previously found in the literature, which further validates the approach. Daily calibration repeatability (n = 4) was +/- 3.0% RSD and over a three month period reproducibility was +/- 12.1% RSD (n = 56). As a further application, we attempted to monitor the sweat of Cystic Fibrosis (CF) sufferers using the same device. We observed high sodium concentrations symptomatic of CF (similar to 60 mM Na(+)) for two CF patients, with no conclusive results for the remaining patients due to their limited exercising capability, and high viscosity/low volume of sweat produced.
引用
收藏
页码:342 / 348
页数:7
相关论文
共 50 条
  • [21] A Capacitive Sweat Rate Sensor for Continuous and Real-Time Monitoring of Sweat Loss
    Choi, Dong-Hoon
    Gonzales, Mark
    Kitchen, Grant B.
    Phan, Dinh-Tuan
    Searson, Peter C.
    ACS SENSORS, 2020, 5 (12) : 3821 - 3826
  • [22] A wearable microfluidic system for efficient sweat collection and real-time detection
    Yin, Yingda
    Tan, Zhiguang
    Zhu, Wangwang
    Pu, Zhihua
    Yu, Haixia
    Wang, Ridong
    Li, Dachao
    TALANTA, 2024, 274
  • [23] Innovative Wearable Sweat Sensor Array for Real-Time Volatile Organic Compound Detection in Noninvasive Diabetes Monitoring
    Binabaji, Fatemeh
    Dashtian, Kheibar
    Zare-Dorabei, Rouholah
    Naseri, Neda
    Noroozifar, Meissam
    Kerman, Kagan
    ANALYTICAL CHEMISTRY, 2024, 96 (33) : 13522 - 13532
  • [24] Research progress in wearable electrochemical sensor for sweat detection
    Tang L.
    Li Y.
    Mao J.
    Wang J.
    Wang L.
    Fangzhi Xuebao/Journal of Textile Research, 2023, 44 (03): : 221 - 230
  • [25] A Wearable Electrochemical Sensor for Testing Carcinoembryonic Antigen in Sweat
    Cao, Xinyu
    Gao, Yisheng
    Ding, Weiping
    Li, Chengpan
    PROCEEDINGS OF 2023 4TH INTERNATIONAL SYMPOSIUM ON ARTIFICIAL INTELLIGENCE FOR MEDICINE SCIENCE, ISAIMS 2023, 2023, : 722 - 727
  • [26] In vivo real-time measurement of superoxide anion radical with a novel electrochemical sensor
    Fujita, Motoki
    Tsuruta, Ryosuke
    Kasaoka, Shunji
    Fujimoto, Kenji
    Tanaka, Ryo
    Oda, Yasutaka
    Nanba, Masahiro
    Igarashi, Masatsugu
    Yuasa, Makoto
    Yoshikawa, Toshikazu
    Maekawa, Tsuyoshi
    FREE RADICAL BIOLOGY AND MEDICINE, 2009, 47 (07) : 1039 - 1048
  • [27] Wearable Autonomous Microsystem with Electrochemical Gas Sensor Array for Real-Time Health and Safety Monitoring
    Li, Haitao
    Mu, Xiaoyi
    Wang, Zhe
    Liu, Xiaowen
    Guo, Min
    Jin, Rong
    Zeng, Xiangqun
    Mason, Andrew J.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 503 - 506
  • [28] Sweat Sodium Concentration Accuracy For A Wearable Fabric Sensor And Two Hydration Monitors During Running
    Otterstetter, Ronald
    Daniels, Shelby
    Cheney, Zachary
    Ellis, Rebecca
    Fulmer, Michael
    Monty-Bromer, Chelsea
    Nicodemus, Mary Pat
    Stege, Victoria
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 393 - 393
  • [29] Achievements and Challenges for Real-Time Sensing of Analytes in Sweat within Wearable Platforms
    Brothers, Michael C.
    DeBrosse, Madeleine
    Grigsby, Claude C.
    Naik, Rajesh R.
    Hussain, Saber M.
    Heikenfeld, Jason
    Kim, Steve S.
    ACCOUNTS OF CHEMICAL RESEARCH, 2019, 52 (02) : 297 - 306
  • [30] A Fully Elastic Wearable Electrochemical Sweat Detection System of Tree-Bionic Microfluidic Structure for Real-Time Monitoring
    Niu, Jiaqi
    Lin, Shujing
    Chen, Di
    Wang, Zhitao
    Cao, Cheng
    Gao, Ang
    Cui, Shengsheng
    Liu, Yanlei
    Hong, Yuping
    Zhi, Xiao
    Cui, Daxiang
    SMALL, 2024, 20 (11)