摘要
The purpose of the present study was to evaluate the feasibility of blood pressure (BP) estimation by means of pulse arrival time (PAT) from data records of ICU patients available at the MIMIC public database. Datasets consisting of ECG, PPG and arterial BP waveforms from 8 subjects were used for the analysis and the relationship of PAT with systolic, diastolic and mean blood pressure was assessed through a linear regression fit. The analysis was carried out on datasets of short (20 min) and long (60 min) duration in order to evaluate the temporal changes on the linear relationship. The results showed high correlation between BP and PAT for both the short-term and the long-term analyses. The mean absolute error found between the true and estimated systolic BP values was close to 5mmHg; however, the error noticeably increased on the long-term dataset for all subjects.
引用
收藏
页码:1113 / 1116
页数:4
相关论文
共 50 条
  • [21] Estimation of Blood Pressure from Non-invasive Data
    Shukla, Satya Narayan
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 1772 - 1775
  • [22] Non-invasive Blood Pressure Estimation Using Phonocardiogram
    Dastjerdi, Amirhossein Esmaili
    Kachuee, Mohammad
    Shabany, Mahdi
    2017 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2017, : 80 - 83
  • [23] Non-Invasive Estimation of Pulse Pressure in HeartMate 3 Patients
    Gaudig, A.
    Pinsino, A.
    Braghieri, L.
    Wang, Y.
    Mondellini, G. M.
    Hastie, J. M.
    Panzer, O.
    Takeda, K.
    Naka, Y.
    Sayer, G. T.
    Uriel, N.
    Yuzefpolskaya, M.
    Colombo, P. C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S99 - S100
  • [24] Feasibility of continuous non-invasive blood pressure measurement in infants
    Schraa, O
    Andriessen, P
    Smit, B
    van den Bosch-Ruis, W
    van Koppen, M
    Settels, JJ
    JOURNAL OF HYPERTENSION, 2004, 22 : S280 - S280
  • [25] Methods for Continuous Non-invasive Measurement of Blood Pressure: Pulse Transit Time a Review
    Kaur, Harleen
    Bhutto, Javed Khan
    Choudhary, Bhawani Shankar
    ASIAN JOURNAL OF PHARMACEUTICS, 2018, 12 (03) : S863 - S872
  • [26] Continuous non-invasive blood pressure during continuous repositioning by pulse transit time
    Jeong, Hieyong
    Yoshimoto, Kayo
    Wang, Tianyi
    Ohno, Takafumi
    Yamada, Kenji
    Kido, Michiko
    Ohno, Yuko
    COGENT ENGINEERING, 2016, 3 (01):
  • [27] Non-invasive blood pressure data acquisition employing pulse transit time detection
    Kerola, J
    Kontra, V
    Sepponen, R
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1308 - 1309
  • [28] Pulse Arrival Time and Ballistocardiogram Application to Blood Pressure Variability Estimation
    Pinheiro, Eduardo
    Postolache, Octavian
    Girao, Pedro
    MEMEA: 2009 IEEE INTERNATIONAL WORKSHOP ON MEDICAL MEASUREMENTS AND APPLICATIONS, 2009, : 132 - +
  • [29] PTT Based Continuous Time Non-invasive Blood Pressure System
    Atef, Mohamed
    Li Xiyan
    Wang, Guoxing
    Lian, Yong
    2016 IEEE 59TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2016, : 329 - 332
  • [30] Non-Invasive Blood Glucose Sensor: A Feasibility Study
    Lopez Albalat, Alvaro
    Sanz Alaman, Maria Begona
    Dejoz Diez, Maria Cristina
    Martinez-Millana, Antonio
    Traver Salcedo, Vicente
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 1179 - 1182