3D deconvolution in Fourier integral microscopy

被引:4
|
作者
Stefanoiu, Anca [1 ]
Scrofani, Gabriele [2 ]
Saavedra, Genaro [2 ]
Martinez-Corral, Manuel [2 ]
Lasser, Tobias [1 ]
机构
[1] Tech Univ Munich, Dept Informat, Munich, Germany
[2] Univ Valencia, Opt Dept, Valencia, Spain
来源
COMPUTATIONAL IMAGING V | 2020年 / 11396卷
关键词
light field microscopy; Fourier integral imaging; deconvolution; 3D reconstruction; expectation maximization; penalized likelihood; regularization; total variation; LIGHT-FIELD; RESOLUTION; ALGORITHM; LIKELIHOOD; REMOVAL;
D O I
10.1117/12.2558516
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fourier integral microscopy (FiMic), also referred to as Fourier light field microscopy (FLFM) in the literature, was recently proposed as an alternative to conventional light field microscopy (LFM). FiMic is designed to overcome the non-uniform lateral resolution limitation specific to LFM. By inserting a micro-lens array at the aperture stop of the microscope objective, the Fourier integral microscope directly captures in a single-shot a series of orthographic views of the scene from different viewpoints. We propose an algorithm for the deconvolution of FiMic data by combining the well known Maximum Likelihood Expectation (MLEM) method with total variation (TV) regularization to cope with noise amplification in conventional Richardson-Lucy deconvolution.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Guidelines for Adapting Light Microscopy Deconvolution Methods to 3D Biological STEM
    Northan, B. M.
    Sougrat, R.
    de Jonge, N.
    MICROSCOPY AND MICROANALYSIS, 2009, 15 : 628 - 629
  • [12] Digital slicing of 3D scenes by Fourier filtering of integral images
    Saavedra, G.
    Martinez-Cuenca, R.
    Martinez-Corral, M.
    Navarro, H.
    Daneshpanah, M.
    Javidi, B.
    OPTICS EXPRESS, 2008, 16 (22) : 17154 - 17160
  • [13] DECONVOLUTION IN 3-D OPTICAL MICROSCOPY
    SHAW, P
    HISTOCHEMICAL JOURNAL, 1994, 26 (09): : 687 - 694
  • [14] Fourier DiffuserScope: single-shot 3D Fourier light field microscopy with a diffuser
    Liu, Fanglin Linda
    Kuo, Grace
    Antipa, Nick
    Yanny, Kyrollos
    Waller, Laura
    OPTICS EXPRESS, 2020, 28 (20) : 28969 - 28986
  • [15] 3D INTEGRAL MICROSCOPY BASED IN FAR-FIELD DETECTION
    Scrofani, G.
    Sola-Pikabea, J.
    Llavador, A.
    Sanchez-Ortiga, E.
    Barreiro, J. C.
    Garcia-Sucerquia, J.
    Incardona, N.
    Martinez-Corral, M.
    THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2018, 2018, 10666
  • [16] Parallel Deconvolution of Large 3D Images Obtained by Confocal Laser Scanning Microscopy
    Pawliczek, Piotr
    Romanowska-Pawliczek, Anna
    Soltys, Zbigniew
    MICROSCOPY RESEARCH AND TECHNIQUE, 2010, 73 (03) : 187 - 194
  • [17] An integral equation theory for 3D solvation structure: A new procedure free from 3D Fourier transform
    Yokogawa, Daisuke
    Sato, Hirofumi
    Sakaki, Shigeyoshi
    CHEMICAL PHYSICS LETTERS, 2006, 432 (4-6) : 595 - 599
  • [18] Application of the split-gradient method to 3D image deconvolution in fluorescence microscopy
    Vicidomini, G.
    Boccacci, P.
    Diaspro, A.
    Bertero, M.
    JOURNAL OF MICROSCOPY, 2009, 234 (01) : 47 - 61
  • [19] 3D optical microscopy method based on synthetic aperture integral imaging
    Lee, Joon-Jae
    Shin, Donghak
    Lee, Byung-Gook
    Yoo, Hoon
    3D RESEARCH, 2012, 3 (04) : 1 - 6
  • [20] A fast thresholded landweber algorithm for general wavelet bases: Application to 3D deconvolution microscopy
    Vonesch, Cedric
    Unser, Michael
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1351 - 1354