The intra- and inter-instrument reliability of DXA based on ex vivo soft tissue measurements

被引:71
|
作者
Guo, Y [1 ]
Franks, PW [1 ]
Brookshire, T [1 ]
Tataranni, PA [1 ]
机构
[1] NIDDKD, Clin Diabet & Nutr Sect, NIH, Phoenix, AZ 85016 USA
来源
OBESITY RESEARCH | 2004年 / 12卷 / 12期
关键词
phantom; DXA; comparison; percentage of fat; reliability;
D O I
10.1038/oby.2004.241
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Comparison of ex-vivo soft tissue measurements using the GE/Lunar pencil (DPX-L; GE/Lunar Co., Madison, WI) and fan beam (Prodigy dual-energy X-ray absorptiometers (DXA) GE/Lunar Co.). Research Methods and Procedures: Intra-instrument reliability was assessed by repeatedly scanning soft tissue phantoms for lean tissue (water) and fat tissue (methanol) using one DPX-L and two identical Prodigy DXAs at fast, medium, and slow scan modes. For each machine, 10 scans of each phantom were performed at each scan speed. The number of scans per instrument totaled 60. Data were analyzed using ANOVA to ascertain whether scan speed affected the intra-instrument reliability and to test whether soft tissue measurements differed among instruments. Percentage fat (phantom density) was the outcome variable. Results: Intra-instrument reliability, expressed as coefficient of variation, ranged between 0.7% and 5.2% for the DPX-L and 0.4% and 4.5% for the Prodigy, with the lowest coefficients of variation observed when scanning the fat tissue phantom. Scan speed also affected the intra-instrument reliability (p < 0.01). Furthermore, differences in the measurement of percentage body fat for both the lean and fat tissue phantoms were observed among all three absorptiometers (all p < 0.01). After adjusting for scan speed, differences persisted for all three instruments. Discussion: Intra- and inter-instrument reliability of DXA machines, even those from the same manufacturer, remains unpredictable. Thus, when measuring body composition using DXA, it is important to consider that even in the absence of measurement bias, the use of different DXA machines, particularly when using a variety of speed settings, will increase the residual error around the true value.
引用
收藏
页码:1925 / 1929
页数:5
相关论文
共 50 条
  • [1] Intra- and Inter-Instrument Reliability of the Actiwatch 4 Accelerometer in a Mechanical Laboratory Setting
    Routen, Ashley C.
    Upton, Dominic
    Edwards, Martin G.
    Peters, Derek M.
    JOURNAL OF HUMAN KINETICS, 2012, 31 : 17 - 24
  • [2] Intra- and inter-instrument reliability of Grip-Strength Measurements: GripTrack (TM) and Jamar (R) hand dynamometers
    Svens, Birgit
    Lee, Hoe
    HAND THERAPY, 2005, 10 (02) : 47 - 55
  • [3] Intra- and inter-examiner reliability of direct facial soft tissue measurements using digital calipers
    Mollov, Nikolay
    Bosio, Jose Antonio
    Pruszynski, Jessica
    Wirtz, Thomas
    JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2012, 1 (04) : E157 - E161
  • [4] Inter-rater, intra-rater and inter-instrument reliability of an electrogoniometer to measure wrist range of motion
    da Silva Camassuti, Patricia Aparecida
    Marcolino, Alexandre Marcio
    Tamanini, Guilherme
    Barbosa, Rafael Inacio
    Barbosa, Amanda Matias
    Registro Fonseca, Marisa de Cassia
    HAND THERAPY, 2015, 20 (01) : 3 - 10
  • [5] Intra- and inter-observer reliability in anthropometric measurements in children
    Stomfai, S.
    Ahrens, W.
    Bammann, K.
    Kovacs, E.
    Marild, S.
    Michels, N.
    Moreno, L. A.
    Pohlabeln, H.
    Siani, A.
    Tornaritis, M.
    Veidebaum, T.
    Molnar, D.
    INTERNATIONAL JOURNAL OF OBESITY, 2011, 35 : S45 - S51
  • [6] Intra- and inter-observer reliability in anthropometric measurements in children
    S Stomfai
    W Ahrens
    K Bammann
    É Kovács
    S Mårild
    N Michels
    L A Moreno
    H Pohlabeln
    A Siani
    M Tornaritis
    T Veidebaum
    D Molnár
    International Journal of Obesity, 2011, 35 : S45 - S51
  • [7] Intra- and Inter-Rater Reliability of a Ballet-based Dance Technique Screening Instrument
    Bronner, Shaw
    Lassey, Ivetta
    Lesar, Jessie R.
    Shaver, Zachary G.
    Turner, Catherine
    MEDICAL PROBLEMS OF PERFORMING ARTISTS, 2020, 35 (01) : 28 - 34
  • [8] Intra- and inter-rater reliability in ultrasonographic measurements of coracohumeral distance
    Guerra-Rodriguez, Diego
    Guerrero-Henriquez, Juan
    Basilio, Daniel
    Mendez-Rebolledo, Guillermo
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2024, 69
  • [9] INTRAOBSERVER INTRA- AND INTER-METHOD RELIABILITY IN BREAST DENSITY MEASUREMENTS
    Jobling, Judith M.
    D'Este, Catherine A.
    Forbes, John F.
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2014, 10 : 14 - 15
  • [10] Intra- and inter-examiner reliability of measurements of chest expansion in ankylosing spondylitis (AS)
    Egsmose, C.
    Rytter, A.
    Hansen, L.
    Suetta, C.
    Rintek Madsen, O.
    SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2006, 35 : 49 - 49