Evidence of Air Trapping During Ex Vivo Lung Perfusion: A Swine Experimental Lung Imaging and Mechanics Study

被引:6
|
作者
Santini, A. [1 ,2 ]
Fumagalli, J. [1 ]
Merrino, A. [3 ]
Protti, I. [3 ]
Paleari, M. C. [3 ]
Montoli, M. [4 ]
Dondossola, D. [3 ,5 ]
Gori, F. [1 ]
Righi, I. [4 ]
Rosso, L. [4 ]
Gatti, S. [6 ]
Pesenti, A. [1 ,3 ]
Grasselli, G. [1 ,3 ]
Zanella, A. [1 ,3 ]
机构
[1] Fdn IRCCS Ca Granda Osped Maggiore Policlin, Dipartimento Anestesia Rianimaz & Emergenza, Milan, Italy
[2] IRCCS, Humanitas Clin & Res Ctr, Dipartimento Anestesia & Terapie Intens, Milan, Italy
[3] Univ Milan, Dipartimento Fisiopatol Med Chirurg & Trapianti, Via Commenda 16, I-20122 Milan, Italy
[4] Fdn IRCCS Ca Granda Osped Maggiore Policlin, Dipartimento Chirurg Torac, Milan, Italy
[5] Fdn IRCCS Ca Granda Osped Maggiore Policlin, Dipartimento Chirurg Gen & Trapianti Fegato, Milan, Italy
[6] Fdn IRCCS Ca Granda Osped Maggiore Policlin, Ctr Ric Preclin, Milan, Italy
关键词
EXPIRATORY FLOW LIMITATION; ACUTE RESPIRATORY-FAILURE; DONOR LUNG; PRESSURE; VENTILATION; TRANSPLANTATION; DERECRUITMENT; INJURY;
D O I
10.1016/j.transproceed.2020.10.016
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Ex vivo lung perfusion (EVLP) allows the ventilation and perfusion of lungs to evaluate their viability for transplantation. The aim of this study is to compare the mechanical, morphologic and functional properties of lungs during EVLP with values obtained in vivo to guide a safe mechanical ventilation strategy. Lungs from 5 healthy pigs were studied in vivo and during 4 hours of EVLP. Lung compliance, airway resistance, gas exchange, and hemodynamic parameters were collected at positive end-expiratory pressure (PEEP) of 5 cm H2O. Computed tomography was performed at PEEP 0, PEEP 5, and total lung capacity (TLC). Lung pressure-volume (PV) curves were performed from PEEP 0 to TLC. Lung compliance decreased during EVLP (53 +/- 5 mL/cm H2O vs 29 +/- 7 mL/cm H2O, P <.05), and the PV curve showed a lower inflection point. Gas content (528 +/- 118 mL vs 892 +/- 402 mL at PEEP 0) and airway resistance (25 +/- 5 vs 44 +/- 9 cmH(2)O/L*s(-1), P <.05) were higher during EVLP. Alveolar dead space (5% +/- 2% vs 17% +/- 6%, P <.05) and intrapulmonary shunt (9% +/- 2% vs 28% +/- 13%, P <.05) increased ex vivo compared to in vivo, while the partial pressure of oxygen to inspired oxygen fraction ratio (PO2/FiO(2)) did not differ (468 +/- 52 mm Hg vs 536 +/- 14 mm Hg). In conclusion, during EVLP lungs show signs of air trapping and bronchoconstriction, resulting in low compliance and increased alveolar dead space. Intrapulmonary shunt is high despite oxygenation levels acceptable for transplantation.
引用
收藏
页码:457 / 465
页数:9
相关论文
共 50 条
  • [41] The Clinical Significance of Donor Lung Weight at Procurement and during Ex Vivo Lung Perfusion
    Okamoto, T.
    Ayyat, K. S.
    Sakanoue, I.
    Niikawa, H.
    Said, S. A.
    Ahmad, U.
    Unai, S.
    Bribriesco, A.
    Elgharably, H.
    Yun, J. J.
    Budev, M.
    McCurry, K. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S328 - S329
  • [42] CHARACTERIZATION OF MICROPARTICLES DURING LUNG ISCHEMIA IN AN EX VIVO RAT LUNG PERFUSION MODEL
    Olland, A.
    Reeb, J.
    Falcoz, P. E.
    Burban, M.
    Auger, C.
    Schini-Kerth, V.
    Kessler, L.
    Toti, F.
    Kessler, R.
    Massard, G.
    TRANSPLANT INTERNATIONAL, 2015, 28 : 18 - 18
  • [43] Evidence of Chronic Thromboembolic Disease During Ex Vivo Lung Perfusion of DBD Donor Lungs
    Boehm, P. M.
    Auner, S.
    Atteneder, C.
    Fruhmann, N.
    Aigner, C.
    Taghavi, S.
    Hoetzenecker, K.
    Benazzo, A.
    Schwarz, S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (04): : S588 - S588
  • [44] Ex Vivo Porcine Experimental Model for Studying and Teaching Lung Mechanics
    Egusquiza, Milena Gomes Parzianello
    Otsuki, Denise Aya
    Auler Junior, Jose Otavio Costa
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (206):
  • [45] Significance of Lung Weight in Cellular Ex Vivo Lung Perfusion
    Okamoto, Toshihiro
    Niikawa, Hiromichi
    Wheeler, David
    Soliman, Basem
    Ayyat, Kamal S.
    Itoda, Yoshifumi
    Farver, Carol F.
    McCurry, Kenneth R.
    JOURNAL OF SURGICAL RESEARCH, 2021, 260 : 190 - 199
  • [46] Normothermic Ex Vivo Lung Perfusion in Clinical Lung Transplantation
    Yeung J.C.
    Keshavjee S.
    Current Transplantation Reports, 2015, 2 (4) : 324 - 328
  • [47] Application of ex vivo lung perfusion (EVLP) in lung transplantation
    Pan, Xufeng
    Yang, Jun
    Fu, Shijie
    Zhao, Heng
    JOURNAL OF THORACIC DISEASE, 2018, 10 (07) : 4637 - 4642
  • [48] A Novel Perfusion Solution for Use In Ex Vivo Lung Perfusion For Lung Transplant
    McCormack, E.
    Redmond, K.
    Curley, G.
    McLoughlin, P.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2021, 190 (SUPPL 6) : S265 - S265
  • [49] Ex vivo lung perfusion in lung transplantation: a case report
    Yeginsu, Ali
    Balci, Merih Kalamanoglu
    Vayvada, Mustafa
    Erkilinc, Atakan
    Kutlu, Cemal Asim
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 24 (01): : 144 - 147
  • [50] Normothermic Ex Vivo Lung Perfusion in Clinical Lung Transplantation
    Cypel, Marcelo
    Yeung, Jonathan C.
    Liu, Mingyao
    Anraku, Masaki
    Chen, Fengshi
    Karolak, Wojtek
    Sato, Masaaki
    Laratta, Jane
    Azad, Sassan
    Madonik, Mindy
    Chow, Chung-Wai
    Chaparro, Cecilia
    Hutcheon, Michael
    Singer, Lianne G.
    Slutsky, Arthur S.
    Yasufuku, Kazuhiro
    de Perrot, Marc
    Pierre, Andrew F.
    Waddell, Thomas K.
    Keshavjee, Shaf
    NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (15): : 1431 - 1440