Evidence of Air Trapping During Ex Vivo Lung Perfusion: A Swine Experimental Lung Imaging and Mechanics Study

被引:6
|
作者
Santini, A. [1 ,2 ]
Fumagalli, J. [1 ]
Merrino, A. [3 ]
Protti, I. [3 ]
Paleari, M. C. [3 ]
Montoli, M. [4 ]
Dondossola, D. [3 ,5 ]
Gori, F. [1 ]
Righi, I. [4 ]
Rosso, L. [4 ]
Gatti, S. [6 ]
Pesenti, A. [1 ,3 ]
Grasselli, G. [1 ,3 ]
Zanella, A. [1 ,3 ]
机构
[1] Fdn IRCCS Ca Granda Osped Maggiore Policlin, Dipartimento Anestesia Rianimaz & Emergenza, Milan, Italy
[2] IRCCS, Humanitas Clin & Res Ctr, Dipartimento Anestesia & Terapie Intens, Milan, Italy
[3] Univ Milan, Dipartimento Fisiopatol Med Chirurg & Trapianti, Via Commenda 16, I-20122 Milan, Italy
[4] Fdn IRCCS Ca Granda Osped Maggiore Policlin, Dipartimento Chirurg Torac, Milan, Italy
[5] Fdn IRCCS Ca Granda Osped Maggiore Policlin, Dipartimento Chirurg Gen & Trapianti Fegato, Milan, Italy
[6] Fdn IRCCS Ca Granda Osped Maggiore Policlin, Ctr Ric Preclin, Milan, Italy
关键词
EXPIRATORY FLOW LIMITATION; ACUTE RESPIRATORY-FAILURE; DONOR LUNG; PRESSURE; VENTILATION; TRANSPLANTATION; DERECRUITMENT; INJURY;
D O I
10.1016/j.transproceed.2020.10.016
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Ex vivo lung perfusion (EVLP) allows the ventilation and perfusion of lungs to evaluate their viability for transplantation. The aim of this study is to compare the mechanical, morphologic and functional properties of lungs during EVLP with values obtained in vivo to guide a safe mechanical ventilation strategy. Lungs from 5 healthy pigs were studied in vivo and during 4 hours of EVLP. Lung compliance, airway resistance, gas exchange, and hemodynamic parameters were collected at positive end-expiratory pressure (PEEP) of 5 cm H2O. Computed tomography was performed at PEEP 0, PEEP 5, and total lung capacity (TLC). Lung pressure-volume (PV) curves were performed from PEEP 0 to TLC. Lung compliance decreased during EVLP (53 +/- 5 mL/cm H2O vs 29 +/- 7 mL/cm H2O, P <.05), and the PV curve showed a lower inflection point. Gas content (528 +/- 118 mL vs 892 +/- 402 mL at PEEP 0) and airway resistance (25 +/- 5 vs 44 +/- 9 cmH(2)O/L*s(-1), P <.05) were higher during EVLP. Alveolar dead space (5% +/- 2% vs 17% +/- 6%, P <.05) and intrapulmonary shunt (9% +/- 2% vs 28% +/- 13%, P <.05) increased ex vivo compared to in vivo, while the partial pressure of oxygen to inspired oxygen fraction ratio (PO2/FiO(2)) did not differ (468 +/- 52 mm Hg vs 536 +/- 14 mm Hg). In conclusion, during EVLP lungs show signs of air trapping and bronchoconstriction, resulting in low compliance and increased alveolar dead space. Intrapulmonary shunt is high despite oxygenation levels acceptable for transplantation.
引用
收藏
页码:457 / 465
页数:9
相关论文
共 50 条
  • [31] Is perfusate exchange during ex vivo lung perfusion beneficial?
    Kao, Christina C.
    Parulekar, Amit D.
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (03)
  • [32] Surfactant Metabolism During Normothermic Ex Vivo Lung Perfusion
    Thakuria, L.
    Romano, R.
    Goss, V.
    Koster, G.
    Townsend, P.
    Popov, A.
    de Robertis, F.
    Pitt, T.
    Carby, M.
    Simon, A.
    Marczin, N.
    Griffiths, M.
    Postle, A.
    Reed, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S91 - S91
  • [33] Subnormothermic Ex Vivo Lung Perfusion Improves Graft Preservation in Rat Ex Vivo Lung Perfusion Model
    Citak, N.
    Arni, S.
    Cehn, J.
    Ceulemans, L.
    Schmitt-Opitz, I.
    Inci, I.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S354 - S354
  • [34] Screening for Donor Lung Pulmonary Emboli During Ex-Vivo Lung Perfusion
    Ayyat, K. S.
    Okamoto, T.
    Tantawi, A.
    Sakanoue, I.
    Elgharably, H.
    Ahmad, U.
    Unai, S.
    Yun, J.
    Budev, M.
    McCurry, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S39 - S39
  • [35] Neutrophil Elastase Inhibitor Improves Lung Function during Ex Vivo Lung Perfusion
    Harada, M.
    Oto, T.
    Okada, M.
    Nishikawa, H.
    Iga, N.
    Miyoshi, K.
    Otani, S.
    Sugimoto, S.
    Yamane, M.
    Miyoshi, S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (04): : S221 - S222
  • [36] Clinical significance of donor lung weight at procurement and during ex vivo lung perfusion
    Okamoto, Toshihiro
    Ayyat, Kamal S.
    Sakanoue, Ichiro
    Niikawa, Hiromichi
    Said, Sayf A.
    Ahmad, Usman
    Unai, Shinya
    Bribriesco, Alejandro
    Elgharably, Haytham
    Budev, Marie M.
    Yun, James J.
    McCurry, Kenneth R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (06): : 818 - 828
  • [37] A neutrophil elastase inhibitor improves lung function during ex vivo lung perfusion
    Harada M.
    Oto T.
    Otani S.
    Miyoshi K.
    Okada M.
    Iga N.
    Nishikawa H.
    Sugimoto S.
    Yamane M.
    Miyoshi S.
    General Thoracic and Cardiovascular Surgery, 2015, 63 (12) : 645 - 651
  • [38] Impact of Heparin on Endothelial Glycocalyx in Lung Grafts during Ex Vivo Lung Perfusion
    Noda, K.
    Philips, B. J.
    Ren, X.
    Sanchez, P. G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S344 - S345
  • [39] Feasibility of lung microdialysis to assess metabolism during clinical ex vivo lung perfusion
    Mazzeo, Anna Teresa
    Fanelli, Vito
    Boffini, Massimo
    Medugno, Mariangela
    Filippini, Claudia
    Simonato, Erika
    Costamagna, Andrea
    Delsedime, Luisa
    Brazzi, Luca
    Rinaldi, Mauro
    Ranieri, V. Marco
    Mascia, Luciana
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (03): : 267 - 276
  • [40] Potential therapeutic targets for lung repair during human ex vivo lung perfusion
    Wong, Aaron
    Zamel, Ricardo
    Yeung, Jonathan
    Bader, Gary D.
    Dos Santos, Claudia C.
    Bai, Xiaohui
    Wang, Yubo
    Keshavjee, Shaf
    Liu, Mingyao
    EUROPEAN RESPIRATORY JOURNAL, 2020, 55 (04)