Two-column Sequential Injection Chromatography-New approach for fast and effective analysis and its comparison with gradient elution chromatography

被引:19
|
作者
Chocholous, Petr [1 ]
Satinsky, Dalibor [1 ]
Sklenarova, Hana [1 ]
Solich, Petr [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, Fac Pharm, Hradec Kralove 50005, Czech Republic
关键词
Sequential injection chromatography; Two-column chromatography; Monolithic column; Paracetamol; Caffeine; Propyphenazone; PHASE LIQUID-CHROMATOGRAPHY; MONOLITHIC COLUMN; LOSARTAN POTASSIUM; PERFORMANCE; COSMETICS; SYSTEM; HYDROCHLOROTHIAZIDE; ANTIOXIDANTS; SEPARATION; TABLETS;
D O I
10.1016/j.aca.2010.01.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents novel approach in low-pressure chromatography flow systems two-column Sequential Injection Chromatography (2-C SIC) and its comparison with gradient elution chromatography on the same instrument. The system was equipped with two different chromatographic columns (connected to selection valve in parallel design) for isocratic separation and determination of all components in composed anti-inflammatory pharmaceutical preparation (tablets). The sample was first injected on the first column of length 30 mm where less retained analytes were separated and then the sample was injected on the second column of length 10 mm where more retained analytes were separated. The SIC system was based on a commercial SIChrom(TM) manifold (8-port high-pressure selection valve and medium-pressure syringe pump with 4 mL reservoir) (FIAlab(R), USA) with two commercially available monolithic columns the "first column" Chromolith(R) Flash RP-18e (25 mm x 4.6 mm id. with guard column 5 mm x 4.6 mm i.d.) and the "second column" Chromolith(R) RP-18e (10 mm x 4.6 mm id.) and CCD UV-vis detector USB 4000 with micro-volume 1.0 cm Z flow cell. Two mobile phases were used for analysis (one for each column). The mobile phase 1 used for elution of paracetamol, caffeine and salicylic acid (internal standard) was acetonitrile/water (10:90, v/v, the water part of pH 3.5 adjusted with acetic acid), flow rate was 0.9 mL min(-1) (volume 3.0 mL of mobile phase per analysis). The mobile phase 2 used for elution of propyphenazone was acetonitrile/water (30:70, v/v); flow rate was 1.2 mL min(-1) (volume 1.5 mL of mobile phase per analysis). Absorbance was monitored at 210 nm. Samples were prepared by dissolving of one tablet in 30% acetonitrile and 10 mu L of filtered supernatant was injected on each column (2 x 10 mu L). The chromatographic resolution between all compounds was >1.45 and analysis time was 5.5 min under the optimal conditions. Limits of detection were determined at 0.4 mu g mL(-1) for paracetamol, at 0.5 mu g mL(-1) for caffeine and at 0.7 mu g mL(-1) for propyphenazone. The new two-column chromatographic set-up developed as an alternative approach to gradient elution chromatography shows evident advantages (time and solvent reduction more than one-third) as compared with single-column gradient SIC method with Chromolith(R) Flash RP-18 (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.). (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 50 条
  • [41] Optimized analysis for related substances in spiramycin based on high performance liquid chromatography with hybrid particle column and characterization of its impurities by single heartcut two-dimensional liquid chromatography coupled with quadrupole time-of-flight mass spectrometer
    Yao, Yuan
    Wang, Qian
    Lu, Yue
    Zhang, Jinlin
    Yao, Weifeng
    Yuan, Yaozuo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2025, 252
  • [42] Automated pre-column derivatization of thiolic fruit-antibrowning agents by sequential injection coupled to high-performance liquid chromatography using a monolithic stationary phase and an in-loop stopped-flow approach
    Karakosta, Theano D.
    Tzanavaras, Paraskevas D.
    Themelis, Demetrius G.
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (16-17) : 2240 - 2246
  • [43] Development and validation of a novel quantification approach for gradient elution reversed phase high-performance liquid chromatography coupled to tandem ICP-mass spectrometry (RP-HPLC-ICP-MS/MS) and its application to diclofenac and its related compounds
    Klencsar, Balazs
    Balcaen, Lieve
    Cuyckens, Filip
    Lynen, Frederic
    Vanhaecke, Frank
    ANALYTICA CHIMICA ACTA, 2017, 974 : 43 - 53
  • [44] Application of high-performance liquid chromatography with amperometric and coulometric detection to the analysis of SZ1677, a new neuromuscular blocking agent, and its two derivatives
    Blazewicz, Agata
    Fijalek, Zbigniew
    Warowna-Grzeskiewicz, Malgorzata
    Banasiuk, Justyna
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1204 (01) : 114 - 118
  • [45] Comprehensive two-dimensional gas chromatography in the analysis of volatile samples of natural origin: A multidisciplinary approach to evaluate the influence of second dimension column coated with mixed stationary phases on system orthogonality
    Cordero, Chiara
    Rubiolo, Patrizia
    Sgorbini, Barbara
    Galli, Mario
    Bicchi, Carlo
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1132 (1-2) : 268 - 279
  • [46] LIQUID-CHROMATOGRAPHY OF POLYMER MIXTURES APPLYING COMBINATION OF EXCLUSION AND FULL ADSORPTION MECHANISMS .1. ANALYSIS OF POLYSTYRENE IN ITS MIXTURE WITH POLYMETHYLMETHACRYLATE SINGLE-COLUMN SINGLE ELUENT APPROACH
    JANCO, M
    PRUDSKOVA, T
    BEREK, D
    JOURNAL OF APPLIED POLYMER SCIENCE, 1995, 55 (03) : 393 - 397
  • [47] Method development and application of offline two-dimensional liquid chromatography/quadrupole time-of-flight mass spectrometry-fast data directed analysis for comprehensive characterization of the saponins from Xueshuantong Injection
    Yang, Wenzhi
    Zhang, Jingxian
    Yao, Changliang
    Qiu, Shi
    Chen, Ming
    Pan, Huiqin
    Shi, Xiaojian
    Wu, Wanying
    Guo, Dean
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 128 : 322 - 332
  • [48] Comparison of a new high-resolution monolithic column with core-shell and fully porous columns for the analysis of retinol and α-tocopherol in human serum and breast milk by ultra-high-performance liquid chromatography
    Kucerova, Barbora
    Krcmova, Lenka
    Solichova, Dagmar
    Plisek, Jiri
    Solich, Petr
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (14) : 2223 - 2230
  • [49] A core-shell column approach to a comprehensive high-performance liquid chromatography phenolic analysis of Vitis vinifera L. and interspecific hybrid grape juices, wines, and other matrices following either solid phase extraction or direct injection
    Manns, David C.
    Mansfield, Anna Katharine
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1251 : 111 - 121
  • [50] Fully automated solid-phase microextraction-fast gas chromatography-mass spectrometry method using a new ionic liquid column for high-throughput analysis of sarcosine and N-ethylglycine in human urine and urinary sediments
    Bianchi, F.
    Dugheri, S.
    Musci, M.
    Bonacchi, A.
    Salvadori, E.
    Arcangeli, G.
    Cupelli, V.
    Lanciotti, M.
    Masieri, L.
    Serni, S.
    Carini, M.
    Careri, M.
    Mangia, A.
    ANALYTICA CHIMICA ACTA, 2011, 707 (01) : 197 - 203