Two-column Sequential Injection Chromatography-New approach for fast and effective analysis and its comparison with gradient elution chromatography

被引:19
|
作者
Chocholous, Petr [1 ]
Satinsky, Dalibor [1 ]
Sklenarova, Hana [1 ]
Solich, Petr [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, Fac Pharm, Hradec Kralove 50005, Czech Republic
关键词
Sequential injection chromatography; Two-column chromatography; Monolithic column; Paracetamol; Caffeine; Propyphenazone; PHASE LIQUID-CHROMATOGRAPHY; MONOLITHIC COLUMN; LOSARTAN POTASSIUM; PERFORMANCE; COSMETICS; SYSTEM; HYDROCHLOROTHIAZIDE; ANTIOXIDANTS; SEPARATION; TABLETS;
D O I
10.1016/j.aca.2010.01.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents novel approach in low-pressure chromatography flow systems two-column Sequential Injection Chromatography (2-C SIC) and its comparison with gradient elution chromatography on the same instrument. The system was equipped with two different chromatographic columns (connected to selection valve in parallel design) for isocratic separation and determination of all components in composed anti-inflammatory pharmaceutical preparation (tablets). The sample was first injected on the first column of length 30 mm where less retained analytes were separated and then the sample was injected on the second column of length 10 mm where more retained analytes were separated. The SIC system was based on a commercial SIChrom(TM) manifold (8-port high-pressure selection valve and medium-pressure syringe pump with 4 mL reservoir) (FIAlab(R), USA) with two commercially available monolithic columns the "first column" Chromolith(R) Flash RP-18e (25 mm x 4.6 mm id. with guard column 5 mm x 4.6 mm i.d.) and the "second column" Chromolith(R) RP-18e (10 mm x 4.6 mm id.) and CCD UV-vis detector USB 4000 with micro-volume 1.0 cm Z flow cell. Two mobile phases were used for analysis (one for each column). The mobile phase 1 used for elution of paracetamol, caffeine and salicylic acid (internal standard) was acetonitrile/water (10:90, v/v, the water part of pH 3.5 adjusted with acetic acid), flow rate was 0.9 mL min(-1) (volume 3.0 mL of mobile phase per analysis). The mobile phase 2 used for elution of propyphenazone was acetonitrile/water (30:70, v/v); flow rate was 1.2 mL min(-1) (volume 1.5 mL of mobile phase per analysis). Absorbance was monitored at 210 nm. Samples were prepared by dissolving of one tablet in 30% acetonitrile and 10 mu L of filtered supernatant was injected on each column (2 x 10 mu L). The chromatographic resolution between all compounds was >1.45 and analysis time was 5.5 min under the optimal conditions. Limits of detection were determined at 0.4 mu g mL(-1) for paracetamol, at 0.5 mu g mL(-1) for caffeine and at 0.7 mu g mL(-1) for propyphenazone. The new two-column chromatographic set-up developed as an alternative approach to gradient elution chromatography shows evident advantages (time and solvent reduction more than one-third) as compared with single-column gradient SIC method with Chromolith(R) Flash RP-18 (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.). (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 50 条
  • [21] Two-dimensional liquid chromatography analysis of synthetic polymers using fast size exclusion chromatography at high column temperature
    Im, Kyuhyun
    Park, Hae-woong
    Lee, Sekyung
    Chang, Taihyun
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (21) : 4606 - 4610
  • [22] Fast, comprehensive online two-dimensional high performance liquid chromatography through the use of high temperature ultra-fast gradient elution reversed-phase liquid chromatography
    Stoll, Dwight R.
    Cohen, Jerry D.
    Carr, Peter W.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1122 (1-2) : 123 - 137
  • [23] COUPLED COLUMN CHROMATOGRAPHY EMPLOYING EXCLUSION AND A REVERSED PHASE - POTENTIAL GENERAL APPROACH TO SEQUENTIAL-ANALYSIS
    JOHNSON, EL
    GLOOR, R
    MAJORS, RE
    JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB): : 571 - 585
  • [24] New generation of sequential injection chromatography: Great enhancement of capabilities of separation using flow analysis
    Chocholous, Petr
    Satinsky, Dalibor
    Solich, Petr
    TALANTA, 2019, 204 : 272 - 277
  • [25] Eco-friendly, cost-effective and fast method for the estimation of furosemide and amiloride in tablet formulation by sequential injection chromatography
    Idris, Abubakr M.
    Elgorashe, Rafea E. E.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 69 (12) : 1193 - 1198
  • [26] Eco-friendly, cost-effective and fast method for the estimation of furosemide and amiloride in tablet formulation by sequential injection chromatography
    Abubakr M. Idris
    Rafea E. E. Elgorashe
    Journal of Analytical Chemistry, 2014, 69 : 1193 - 1198
  • [27] Analysis of Dimethylsiloxanes in Hydrocarbon Matrices like Marine Fuels Applying a Novel Enrichment Procedure and a Two-Column Gas Chromatography - Mass Spectrometry Measurement
    Gresch, Janko
    Fuhrlaender, Liliane
    Kolb, Marit
    Wichmann, Hubertus
    ANALYTICAL LETTERS, 2024,
  • [28] BOXCAR CHROMATOGRAPHY - A NEW APPROACH TO INCREASED ANALYSIS RATE AND VERY LARGE COLUMN PLATE NUMBERS
    SNYDER, LR
    DOLAN, JW
    VANDERWAL, S
    JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN): : 3 - 17
  • [29] The optimization of step-gradient elution conditions in liquid chromatography: Application to pesticide residue analysis using coupled-column reversed-phase LC
    Gort, SM
    Hogendoorn, EA
    Dijkman, E
    vanZoonen, P
    Hoogerbrugge, R
    CHROMATOGRAPHIA, 1996, 42 (1-2) : 17 - 24
  • [30] Multilayered particle-packed column: Evaluation and comparison with monolithic and core-shell particle columns for the determination of red azo dyes in Sequential Injection Chromatography
    Chocholous, Petr
    Gil, Renato
    Acebal, Carolina C.
    Kubala, Viktor
    Satnsky, Dalibor
    Solich, Petr
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (06) : 1225 - 1233