Two-column Sequential Injection Chromatography-New approach for fast and effective analysis and its comparison with gradient elution chromatography

被引:19
|
作者
Chocholous, Petr [1 ]
Satinsky, Dalibor [1 ]
Sklenarova, Hana [1 ]
Solich, Petr [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, Fac Pharm, Hradec Kralove 50005, Czech Republic
关键词
Sequential injection chromatography; Two-column chromatography; Monolithic column; Paracetamol; Caffeine; Propyphenazone; PHASE LIQUID-CHROMATOGRAPHY; MONOLITHIC COLUMN; LOSARTAN POTASSIUM; PERFORMANCE; COSMETICS; SYSTEM; HYDROCHLOROTHIAZIDE; ANTIOXIDANTS; SEPARATION; TABLETS;
D O I
10.1016/j.aca.2010.01.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents novel approach in low-pressure chromatography flow systems two-column Sequential Injection Chromatography (2-C SIC) and its comparison with gradient elution chromatography on the same instrument. The system was equipped with two different chromatographic columns (connected to selection valve in parallel design) for isocratic separation and determination of all components in composed anti-inflammatory pharmaceutical preparation (tablets). The sample was first injected on the first column of length 30 mm where less retained analytes were separated and then the sample was injected on the second column of length 10 mm where more retained analytes were separated. The SIC system was based on a commercial SIChrom(TM) manifold (8-port high-pressure selection valve and medium-pressure syringe pump with 4 mL reservoir) (FIAlab(R), USA) with two commercially available monolithic columns the "first column" Chromolith(R) Flash RP-18e (25 mm x 4.6 mm id. with guard column 5 mm x 4.6 mm i.d.) and the "second column" Chromolith(R) RP-18e (10 mm x 4.6 mm id.) and CCD UV-vis detector USB 4000 with micro-volume 1.0 cm Z flow cell. Two mobile phases were used for analysis (one for each column). The mobile phase 1 used for elution of paracetamol, caffeine and salicylic acid (internal standard) was acetonitrile/water (10:90, v/v, the water part of pH 3.5 adjusted with acetic acid), flow rate was 0.9 mL min(-1) (volume 3.0 mL of mobile phase per analysis). The mobile phase 2 used for elution of propyphenazone was acetonitrile/water (30:70, v/v); flow rate was 1.2 mL min(-1) (volume 1.5 mL of mobile phase per analysis). Absorbance was monitored at 210 nm. Samples were prepared by dissolving of one tablet in 30% acetonitrile and 10 mu L of filtered supernatant was injected on each column (2 x 10 mu L). The chromatographic resolution between all compounds was >1.45 and analysis time was 5.5 min under the optimal conditions. Limits of detection were determined at 0.4 mu g mL(-1) for paracetamol, at 0.5 mu g mL(-1) for caffeine and at 0.7 mu g mL(-1) for propyphenazone. The new two-column chromatographic set-up developed as an alternative approach to gradient elution chromatography shows evident advantages (time and solvent reduction more than one-third) as compared with single-column gradient SIC method with Chromolith(R) Flash RP-18 (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.). (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 50 条
  • [1] Two-column sequential injection chromatography for fast isocratic separation of two analytes of greatly differing chemical properties
    Satinsky, Dalibor
    Chocholous, Petr
    Valova, Olga
    Hanusova, Lucia
    Solich, Petr
    TALANTA, 2013, 114 : 311 - 317
  • [2] Simple automated generation of gradient elution conditions in sequential injection chromatography using monolithic column
    Koblova, Petra
    Sklenarova, Hana
    Chocholous, Petr
    Polasek, Miroslav
    Solich, Petr
    TALANTA, 2011, 84 (05) : 1273 - 1277
  • [3] Retention and Bandwidth Predictions by Fast Gradient Elution Chromatography Using a Pillar Array Column
    Song, Yanting
    Takatsuki, Katsuya
    Sekiguchi, Tetsushi
    Funatsu, Takashi
    Shoji, Shuichi
    Tsunoda, Makoto
    CHROMATOGRAPHY, 2016, 37 (03) : 111 - 116
  • [4] A new flow-injection chromatography method exploiting linear-gradient elution for fast quantitative screening of parabens in cosmetics
    Barbatsi, Margarita
    Koupparis, Michael
    Economou, Anastasios
    ANALYTICAL METHODS, 2016, 8 (47) : 8337 - 8344
  • [5] A two-column flash chromatography approach to pyoverdin production from Pseudomonas putida GB1
    Duckworth, Owen W.
    Markarian, Dawn S.
    Parker, Dorothy L.
    Harrington, James M.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2017, 135 : 11 - 13
  • [6] Microplate approach to resin screening and parameter estimation applied to chromatography column modeling of gradient elution operation
    Vieira, Felipe Coelho
    Kopp, Willian
    Furlan, Felipe Fernando
    de Padua, Thiago Faggion
    Ribeiro, Marcelo Perencin de Arruda
    JOURNAL OF CHROMATOGRAPHY A, 2025, 1746
  • [7] Fast separation of red colorants in beverages using cyano monolithic column in Sequential Injection Chromatography
    Chocholous, Petr
    Dedkova, Lucie
    Bohacova, Tereza
    Satinsky, Dalibor
    Solich, Petr
    MICROCHEMICAL JOURNAL, 2017, 130 : 384 - 389
  • [8] ELECTROCHEMICALLY MODULATED LIQUID-CHROMATOGRAPHY (EMLC) - A NEW APPROACH TO GRADIENT ELUTION SEPARATIONS
    DEINHAMMER, RS
    TING, EY
    PORTER, MD
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 362 (1-2): : 295 - 299
  • [9] Enhanced capabilities of separation in Sequential Injection Chromatography - Fused-core particle column and its comparison with narrow-bore monolithic column
    Chocholous, Petr
    Kosarova, Lucie
    Satinsky, Dalibor
    Sklenarova, Hana
    Solich, Petr
    TALANTA, 2011, 85 (02) : 1129 - 1134
  • [10] New approach to linear gradient elution used for optimisation in reversed-phase liquid chromatography
    Nikitas, P
    Pappa-Louisi, A
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1068 (02) : 279 - 287