An accuracy of blood glucose obtained from glucose meter [LDQUO]Standard Gluconavii® GDH Blood Glucose Meter [RDQUO] by testing with arterial and neonatal blood samples

被引:0
|
作者
Thongsukkeang, K. [2 ]
Treebuphachatsakul, W. [3 ]
Apiratmateekul, N. [1 ]
机构
[1] Naresuan Univ, Fac Allied Hlth Sci, Dept Med Technol, Phitsanulok, Thailand
[2] Phu Khiao Chalermprakirt Hosp, Lab Med, Chaiyaphum, Thailand
[3] Naresuan Univ, Fac Allied Hlth Sci, Reference Mat & Med Lab Res Unit, Phitsanulok, Thailand
关键词
D O I
10.1016/j.cca.2022.04.572
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
T104
引用
收藏
页码:S98 / S98
页数:1
相关论文
共 50 条
  • [21] Agreement of blood glucose measured with glucose meter in arterial, central venous, and capillary samples in adult critically ill patients
    Rodriguez-Delgado, Esther
    Garcia del Moral, Raimundo
    Cobos-Vargas, Angel
    Martin-Lopez, Javier
    Colmenero, Manuel
    NURSING IN CRITICAL CARE, 2022, 27 (05) : 711 - 717
  • [22] Haematocrit and the Boehringer Advantage blood glucose meter
    Wiener, K
    ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 : 325 - 326
  • [23] Design & Implementation of a Low Cost Blood Glucose Meter with High Accuracy
    Saha, Shumit
    Sarker, Nayan
    Hira, Avijit
    2014 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATION & COMMUNICATION TECHNOLOGY (ICEEICT 2014), 2014,
  • [24] Accuracy and utility of a 10-test disk blood glucose meter
    Kendall, DM
    Kaplan, RA
    Paulson, CF
    Parkes, JL
    Tideman, AM
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2005, 67 (01) : 29 - 35
  • [25] Glucose measurement for cell culture - GlucCell, a modified blood glucose meter
    Wang, Ing-Kae
    Chang, King-Ming
    Ho, Lewis
    GENETIC ENGINEERING NEWS, 2006, 26 (10): : 40 - +
  • [26] Commutable Blood Materials from the Fixed-Cell Method for Performance Evaluation of Blood Glucose by a Glucose Meter
    Apiratmateekul, Napaporn
    Nammoonnoy, Jintana
    Kost, Gerald J.
    Treebuphachatsakul, Wanvisa
    DIAGNOSTICS, 2024, 14 (08)
  • [27] EVALUATION OF THE EXACTECH BLOOD-GLUCOSE METER FOR ROUTINE BEDSIDE TESTING
    SHARMA, S
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1205 - 1205
  • [28] Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room
    Karon, Brad S.
    Donato, Leslie J.
    Larsen, Chelsie M.
    Siebenaler, Lindsay K.
    Wells, Amy E.
    Wood-Wentz, Christina M.
    Shirk-Marienau, Mary E.
    Curry, Timothy B.
    ANESTHESIOLOGY, 2017, 127 (03) : 466 - 474
  • [29] INTERFERENTS IN GLUCOSE DETERMINATION DO NOT INFLUENCE THE HOSPITAL POC GLUCOSE METER STATSTRIP IN ACCURACY AND PRECISION OF BLOOD GLUCOSE MEASUREMENT
    Schoendorf, T.
    Forst, T.
    Pfuetzner, A.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S687 - S687
  • [30] Use of a blood glucose meter for radiochromic film analysis in blood irradiation
    Cheung, T
    Butson, MJ
    Yu, PKN
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (19): : N259 - N263