Automated 3D trabecular bone structure analysis of the proximal femur-prediction of biomechanical strength by CT and DXA

被引:59
|
作者
Baum, T. [1 ]
Carballido-Gamio, J. [2 ]
Huber, M. B. [2 ]
Mueller, D. [1 ]
Monetti, R. [3 ]
Raeth, C. [3 ]
Eckstein, F. [4 ]
Lochmueller, E. M. [4 ]
Majumdar, S. [2 ]
Rummeny, E. J. [1 ]
Link, T. M. [2 ]
Bauer, J. S. [1 ]
机构
[1] Tech Univ Munich, Inst Rontgendiagnost, Klinikum Rechts Isar, D-81675 Munich, Germany
[2] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94107 USA
[3] Max Planck Inst Extraterr Phys, D-85748 Garching, Germany
[4] Paracelsus Med Univ Salzburg, Inst Anat & Musculoskeletal Res, A-5020 Salzburg, Austria
关键词
Computed tomography; Failure load; Osteoporosis; Proximal femur; Trabecular bone structure; QUANTITATIVE COMPUTED-TOMOGRAPHY; FINITE-ELEMENT-ANALYSIS; RESOLUTION MR-IMAGES; MINERAL DENSITY; IN-VITRO; FEMORAL-NECK; CORTICAL BONE; 1.5; T; HIP; FRACTURE;
D O I
10.1007/s00198-009-1090-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The standard diagnostic technique for assessing osteoporosis is dual X-ray absorptiometry (DXA) measuring bone mass parameters. In this study, a combination of DXA and trabecular structure parameters (acquired by computed tomography [CT]) most accurately predicted the biomechanical strength of the proximal femur and allowed for a better prediction than DXA alone. An automated 3D segmentation algorithm was applied to determine specific structure parameters of the trabecular bone in CT images of the proximal femur. This was done to evaluate the ability of these parameters for predicting biomechanical femoral bone strength in comparison with bone mineral content (BMC) and bone mineral density (BMD) acquired by DXA as standard diagnostic technique. One hundred eighty-seven proximal femur specimens were harvested from formalin-fixed human cadavers. BMC and BMD were determined by DXA. Structure parameters of the trabecular bone (i.e., morphometry, fuzzy logic, Minkowski functionals, and the scaling index method [SIM]) were computed from CT images. Absolute femoral bone strength was assessed with a biomechanical side-impact test measuring failure load (FL). Adjusted FL parameters for appraisal of relative bone strength were calculated by dividing FL by influencing variables such as body height, weight, or femoral head diameter. The best single parameter predicting FL and adjusted FL parameters was apparent trabecular separation (morphometry) or DXA-derived BMC or BMD with correlations up to r = 0.802. In combination with DXA, structure parameters (most notably the SIM and morphometry) added in linear regression models significant information in predicting FL and all adjusted FL parameters (up to R (adj) = 0.872) and allowed for a significant better prediction than DXA alone. A combination of bone mass (DXA) and structure parameters of the trabecular bone (linear and nonlinear, global and local) most accurately predicted absolute and relative femoral bone strength.
引用
收藏
页码:1553 / 1564
页数:12
相关论文
共 50 条
  • [31] BONE HEALTH IN PATIENTS WITH MULTIPLE SCLEROSIS: ANALYSIS OF BONE MINERAL DENSITY AND 3D-RECONSTRUCTION OF PROXIMAL FEMUR BY DXA
    Ulla, M. R.
    Vrech, C.
    Brun, L. R.
    Brance, M. L.
    Lopez, E. Peralta
    Castro, M. J.
    Martos, F.
    Mazzini, S.
    Rivoira, M. A.
    OSTEOPOROSIS INTERNATIONAL, 2021, 32 (SUPPL 1) : S241 - S241
  • [32] Trabecular and cortical bone involvement in rheumatoid arthritis by DXA and DXA-based 3D modelling
    Brance, M. L.
    Pons-Estel, B. A.
    Quagliato, N. J.
    Jorfen, M.
    Berbotto, G.
    Cortese, N.
    Raggio, J. C.
    Palatnik, M.
    Chavero, I.
    Soldano, J.
    Dieguez, C.
    Sanchez, A.
    Del Rio, L.
    Di Gregorio, S.
    Brun, L. R.
    OSTEOPOROSIS INTERNATIONAL, 2021, 32 (04) : 705 - 714
  • [33] The Influence of Exercise on the 3D distribution of Cortical and Trabecular Bone across the Proximal Femur: The HipHop Study.
    Allison, Sarah
    Poole, Kenneth
    Treece, Graham
    Gee, Andrew
    Tonkin, Carol
    Rennie, Winston
    Folland, Jonathan
    Summers, Greg
    Brooke-Wavell, Katherine
    JOURNAL OF BONE AND MINERAL RESEARCH, 2014, 29 : S6 - S6
  • [34] Trabecular and cortical bone involvement in rheumatoid arthritis by DXA and DXA-based 3D modelling
    M.L. Brance
    B.A. Pons-Estel
    N.J. Quagliato
    M. Jorfen
    G. Berbotto
    N. Cortese
    J.C. Raggio
    M. Palatnik
    I. Chavero
    J. Soldano
    C. Dieguez
    A. Sánchez
    L. Del Rio
    S. Di Gregorio
    L.R. Brun
    Osteoporosis International, 2021, 32 : 705 - 714
  • [35] Application of the Minkowski functionals in 3D to high resolution MR images of trabecular bone: Prediction of the biomechanical strength by nonlinear topological measures
    Boehm, HF
    Link, TM
    Monetti, RA
    Mueller, D
    Rummeny, EJ
    Newitt, D
    Majumdar, S
    Raeth, CW
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 172 - 180
  • [36] Local 3D scaling properties for the analysis of trabecular bone extracted from high-resolution magnetic resonance imaging of human trabecular bone - Comparison with bone mineral density in the prediction of biomechanical strength in vitro
    Boehm, HF
    Raeth, C
    Monetti, RA
    Mueller, D
    Newitt, D
    Majumdar, S
    Rummeny, E
    Morfill, G
    Link, TM
    INVESTIGATIVE RADIOLOGY, 2003, 38 (05) : 269 - 280
  • [37] Trabecular Bone Analysis in CT and X-Ray Images of the Proximal Femur for the Assessment of Local Bone Quality
    Fritscher, Karl
    Gruenerbl, Agnes
    Haenni, Markus
    Suhm, Norbert
    Hengg, Clemens
    Schubert, Rainer
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (10) : 1560 - 1575
  • [38] Cortical and Trabecular Bone Response in Proximal Femur from Women with Osteoporosis Treated with Denosumab or Zolendronic Acid using 3D Modelling Techniques obtained from DXA.
    Cons Molina, Fidencio
    Feuchter, Mario
    Ernesto Bejarano, Luis
    Wiluzanski, Diana
    Altieri, Carla
    Romero Galvan, Edison Edgardo
    Luis Mansur, Jose
    Martelli, Yves
    Humbert, Ludovic
    JOURNAL OF BONE AND MINERAL RESEARCH, 2018, 33 : 385 - 385
  • [39] CORTICAL AND TRABECULAR BONE MINERAL CONTENT CHANGES AT THE PROXIMAL FEMUR ASSESSED BY 3D-DXA AFTER PTH (1-84) TREATMENT
    Malouf, J.
    Fonolla, R.
    Martelli, Y.
    Rio Barquero, L. Der
    Di Gregorio, S.
    Humbert, L.
    OSTEOPOROSIS INTERNATIONAL, 2015, 26 : S342 - S342
  • [40] Topological analysis and spatial distribution of apparent trabecular bone in radiographs correlate to biomechanical bone properties: An in vitro study of the proximal femur
    Carballido-Gamio, J.
    Huber, M. B.
    Fritscher, K.
    Schubert, R.
    Haenni, M.
    Hengg, C.
    Majumdar, S.
    Link, T. M.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2007, 22 : S419 - S419