Automated 3D trabecular bone structure analysis of the proximal femur-prediction of biomechanical strength by CT and DXA

被引:59
|
作者
Baum, T. [1 ]
Carballido-Gamio, J. [2 ]
Huber, M. B. [2 ]
Mueller, D. [1 ]
Monetti, R. [3 ]
Raeth, C. [3 ]
Eckstein, F. [4 ]
Lochmueller, E. M. [4 ]
Majumdar, S. [2 ]
Rummeny, E. J. [1 ]
Link, T. M. [2 ]
Bauer, J. S. [1 ]
机构
[1] Tech Univ Munich, Inst Rontgendiagnost, Klinikum Rechts Isar, D-81675 Munich, Germany
[2] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94107 USA
[3] Max Planck Inst Extraterr Phys, D-85748 Garching, Germany
[4] Paracelsus Med Univ Salzburg, Inst Anat & Musculoskeletal Res, A-5020 Salzburg, Austria
关键词
Computed tomography; Failure load; Osteoporosis; Proximal femur; Trabecular bone structure; QUANTITATIVE COMPUTED-TOMOGRAPHY; FINITE-ELEMENT-ANALYSIS; RESOLUTION MR-IMAGES; MINERAL DENSITY; IN-VITRO; FEMORAL-NECK; CORTICAL BONE; 1.5; T; HIP; FRACTURE;
D O I
10.1007/s00198-009-1090-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The standard diagnostic technique for assessing osteoporosis is dual X-ray absorptiometry (DXA) measuring bone mass parameters. In this study, a combination of DXA and trabecular structure parameters (acquired by computed tomography [CT]) most accurately predicted the biomechanical strength of the proximal femur and allowed for a better prediction than DXA alone. An automated 3D segmentation algorithm was applied to determine specific structure parameters of the trabecular bone in CT images of the proximal femur. This was done to evaluate the ability of these parameters for predicting biomechanical femoral bone strength in comparison with bone mineral content (BMC) and bone mineral density (BMD) acquired by DXA as standard diagnostic technique. One hundred eighty-seven proximal femur specimens were harvested from formalin-fixed human cadavers. BMC and BMD were determined by DXA. Structure parameters of the trabecular bone (i.e., morphometry, fuzzy logic, Minkowski functionals, and the scaling index method [SIM]) were computed from CT images. Absolute femoral bone strength was assessed with a biomechanical side-impact test measuring failure load (FL). Adjusted FL parameters for appraisal of relative bone strength were calculated by dividing FL by influencing variables such as body height, weight, or femoral head diameter. The best single parameter predicting FL and adjusted FL parameters was apparent trabecular separation (morphometry) or DXA-derived BMC or BMD with correlations up to r = 0.802. In combination with DXA, structure parameters (most notably the SIM and morphometry) added in linear regression models significant information in predicting FL and all adjusted FL parameters (up to R (adj) = 0.872) and allowed for a significant better prediction than DXA alone. A combination of bone mass (DXA) and structure parameters of the trabecular bone (linear and nonlinear, global and local) most accurately predicted absolute and relative femoral bone strength.
引用
收藏
页码:1553 / 1564
页数:12
相关论文
共 50 条
  • [21] CORTICAL AND TRABECULAR BONE RESPONSES IN THE PROXIMAL FEMUR OF WOMEN WITH OSTEOPOROSIS TREATED WITH DENOSUMAB OR ZOLENDRONIC ACID USING 3D MODELLING TECHNIQUES OBTAINED FROM DXA
    Cons-Molina, F.
    Feuchter, M.
    Bejarano, L.
    Wiluzanski, D.
    Altieri, C.
    Romero, E.
    Mansur, J. L.
    Martelli, Y.
    Humbert, L.
    JCR-JOURNAL OF CLINICAL RHEUMATOLOGY, 2018, 24 : S4 - S5
  • [22] Analyzing the cortical and trabecular bone of the femur of patients with vertebral fractures by 3D-DXA.
    Galich, A. M.
    Humbert, L.
    Winzenrieth, R.
    Maffei, L.
    Premrou, V.
    Frigeri, A.
    Vega, E.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2017, 32 : S91 - S91
  • [23] Effects of osteoporosis drug treatments on cortical and trabecular bone in the femur using DXA-based 3D modeling
    Winzenrieth, R.
    Humbert, L.
    Di Gregorio, S.
    Bonel, E.
    Garcia, M.
    Del Rio, L.
    OSTEOPOROSIS INTERNATIONAL, 2018, 29 (10) : 2323 - 2333
  • [24] Age-related changes in bone density, geometry and biomechanical properties of the proximal femur: CT-based 3D hip structure analysis in normal postmenopausal women
    Ito, Masako
    Nakata, Tomoko
    Nishida, Akifumi
    Uetani, Masataka
    BONE, 2011, 48 (03) : 627 - 630
  • [25] MECHANICAL COMPETENCE OF THE PROXIMAL FEMUR AS PREDICTED FROM DXA: DXA-EQUIVALENT CT (CTXA) AND STRUCTURE ANALYSIS
    Kuhn, Volker
    Leib, Annemaria
    Link, Thomas
    Eckstein, Felix
    OSTEOPOROSIS INTERNATIONAL, 2013, 24 : S323 - S323
  • [26] Effects of osteoporosis drug treatments on cortical and trabecular bone in the femur using DXA-based 3D modeling
    R. Winzenrieth
    L. Humbert
    S. Di Gregorio
    E. Bonel
    M. García
    L. Del Rio
    Osteoporosis International, 2018, 29 : 2323 - 2333
  • [27] ANALYZING THE CORTICAL AND TRABECULAR BONE OF THE FEMUR OF PATIENTS WITH VERTEBRAL FRACTURES USING DXA-BASED 3D MODELING
    Galich, A. M.
    Humbert, L.
    Winzenrieth, R.
    Maffei, L. E.
    Premrou, V.
    Frigeri, A.
    Vega, E.
    OSTEOPOROSIS INTERNATIONAL, 2018, 29 : S496 - S496
  • [28] Structure analysis of high resolution MRI of the proximal femur using a 3D anisotropic method for the prediction of mechanical strength in vitro.
    Monetti, RA
    Boehm, H
    Mueller, D
    Rummeny, E
    Morfill, G
    Majumdar, S
    Newitt, D
    Link, T
    Raeth, C
    JOURNAL OF BONE AND MINERAL RESEARCH, 2004, 19 : S235 - S235
  • [29] 3D analysis of the trabecular bone using micro-CT
    Moon, HS
    Shim, WH
    Lim, BJ
    Kim, KD
    Kim, HJ
    Chung, MK
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B323 - B323
  • [30] Correlation of 2D trabecular structure parameters with 3D μCT and measurements of bone strength in femoral bone cores.
    Arnaud, CD
    Liew, S
    Steines, D
    Nazarian, A
    Mueller, R
    Linder, BJ
    Lang, P
    JOURNAL OF BONE AND MINERAL RESEARCH, 2003, 18 : S56 - S56