Specific approach for membrane fouling control and better treatment performance of an anaerobic submerged membrane bioreactor

被引:22
|
作者
Liu, Yingnan [1 ,2 ,3 ]
Zhang, Xinbo [1 ,2 ,3 ]
Huu Hao Ngo [1 ,2 ,5 ]
Guo, Wenshan [1 ,2 ,5 ]
Wen, Haitao [1 ,2 ,3 ]
Deng, Lijuan [4 ,5 ]
Li, Yajing [1 ,2 ,3 ]
Guo, Jianbo [1 ,2 ,3 ]
机构
[1] Tianjin Chengjian Univ, Sch Environm & Municipal Engn, Joint Res Ctr Protect Infrastruct Technol & Envir, Tianjin, Peoples R China
[2] Univ Technol Sydney, Sch Civil & Environm Engn, Sydney, NSW, Australia
[3] Tianjin Chengjian Univ, Tianjin Key Lab Aquat Sci & Technol, Jinjing Rd 26, Tianjin 300384, Peoples R China
[4] Tianjin Polytech Univ, Sch Environm & Chem Engn, Tianjin 300387, Peoples R China
[5] Univ Technol Sydney, Sch Civil & Environm Engn, Ctr Technol Water & Wastewater, Sydney, NSW 2007, Australia
基金
中国国家自然科学基金;
关键词
Sponge; Anaerobic submerge membrane bioreactor; Membrane fouling; Treatment efficiency; Municipal wastewater; WASTE-WATER TREATMENT; DISSOLVED ORGANIC-MATTER; BED BIOFILM REACTOR; RETENTION TIME; EXCITATION; FILTRATION; CARRIERS; SLUDGE; ANMBR; MBR;
D O I
10.1016/j.biortech.2018.08.043
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
This paper investigated a strategy to minimize membrane fouling and increase treatment efficiency through an investigation of a specific approach by adding sponges into a conventional submerged anaerobic membrane bioreactor (CAnSMBR). During the operation, the protein-based soluble microbial products as the main factor affecting the membrane fouling could be reduced by sponge addition in the CAnSMBR (SAnSMBR). Furthermore, reducing HRT from 18 h to 12 h could shorten the membrane fouling cycle to 62% and 87% in CAnSMBR and SAnSMBR, respectively. At the initial of COD/NO 3 ratio ranges from 5 to 4, only 88% of nitrogen in CAnSMBR was removed, while the SAnSMBR could remove more than 90%. TOC removal efficiency could reach more than 95% under a good stirring scenario. It is evident that the SAnSMBR is a promising solution for improving overall CAnSMBR performance and substantially mitigating membrane fouling.
引用
收藏
页码:658 / 664
页数:7
相关论文
共 50 条
  • [41] Landfill leachate treatment by graphite engineered anaerobic membrane bioreactor: Performance enhancement and membrane fouling mitigation
    Nabi, Mohammad
    Gao, Dawen
    Liang, Hong
    Cheng, Lang
    Yang, Wenbo
    Li, Yuqi
    ENVIRONMENTAL RESEARCH, 2022, 214
  • [42] Assessing the impact of granular anaerobic membrane bioreactor intensification on treatment performance, membrane fouling and economic balance
    Sanchez, Lucie
    Vinardell, Sergi
    Charreton, Jules
    Heran, Marc
    Lesage, Geoffroy
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2023, 11 (02):
  • [43] Effect of filamentous bacteria on membrane fouling in submerged membrane bioreactor
    Meng, FG
    Zhang, HM
    Yang, FL
    Li, YS
    Xiao, JN
    Zhang, XW
    JOURNAL OF MEMBRANE SCIENCE, 2006, 272 (1-2) : 161 - 168
  • [44] Effect of a suspended carrier on membrane fouling in a submerged membrane bioreactor
    Wei, Chun-Hai
    Huang, Xia
    Wang, Cheng-Wen
    Wen, Xiang-Hua
    WATER SCIENCE AND TECHNOLOGY, 2006, 53 (06) : 211 - 220
  • [45] A venturi device reduces membrane fouling in a submerged membrane bioreactor
    Kayaalp, Necati
    Ozturkmen, Gokmen
    WATER SCIENCE AND TECHNOLOGY, 2016, 74 (01) : 147 - 156
  • [46] Mitigated membrane fouling in a vertical submerged membrane bioreactor (VSMBR)
    Chae, So-Ryong
    Ahn, Yong-Tae
    Kang, Seok-Tae
    Shin, Hang-Sik
    JOURNAL OF MEMBRANE SCIENCE, 2006, 280 (1-2) : 572 - 581
  • [47] Membrane fouling in a submerged membrane bioreactor: Impacts of floc size
    Shen, Li-guo
    Lei, Qian
    Chen, Jian-Rong
    Hong, Hua-Chang
    He, Yi-Ming
    Lin, Hong-Jun
    CHEMICAL ENGINEERING JOURNAL, 2015, 269 : 328 - 334
  • [48] Performance of a submerged anaerobic membrane bioreactor with forward osmosis membrane for low-strength wastewater treatment
    Chen, Lin
    Gu, Yangshuo
    Cao, Chuqing
    Zhang, Jun
    Ng, Jing-Wen
    Tang, Chuyang
    WATER RESEARCH, 2014, 50 : 114 - 123
  • [49] Optimizing dose of coagulant and pH values for membrane fouling control in a submerged membrane bioreactor
    Nazmkhah, Abbas
    Oghyanous, Farid Alizad
    Etemadi, Habib
    Yegani, Reza
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2022, 97 (10) : 2794 - 2804
  • [50] Effect of ultrafiltration membrane material on fouling dynamics in a submerged anaerobic membrane bioreactor treating domestic wastewater
    Grossman, Amit Dan
    Yang, Yang
    Yogev, Uri
    Camarena, Daniela Calero
    Oron, Gideon
    Bernstein, Roy
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2019, 5 (06) : 1145 - 1156