A Prophylactic Tibial Stem Reduces Rates of Early Aseptic Loosening in Patients with Severe Preoperative Varus Deformity in Primary Total Knee Arthroplasty

被引:9
|
作者
Hegde, Vishal [1 ,2 ]
Bracey, Daniel N. [1 ,3 ]
Brady, Anna C. [1 ]
Kleeman-Forsthuber, Lindsay T. [1 ]
Dennis, Douglas A. [1 ,4 ,5 ,6 ]
Jennings, Jason M. [1 ,4 ]
机构
[1] Colorado Joint Replacement, 2535 S Downing St,Suite 100, Denver, CO 80210 USA
[2] Johns Hopkins Univ, Dept Orthopaed Surg, Baltimore, MD USA
[3] Univ N Carolina, Dept Orthopaed Surg, Chapel Hill, NC 27515 USA
[4] Univ Denver, Dept Mech & Mat Engn, Denver, CO USA
[5] Univ Colorado, Sch Med, Dept Orthopaed, Denver, CO USA
[6] Univ Tennessee, Dept Biomed Engn, Knoxville, TN USA
来源
JOURNAL OF ARTHROPLASTY | 2021年 / 36卷 / 07期
关键词
varus deformity; total knee arthroplasty; tibial stem extension; aseptic loosening; preoperative alignment; PROXIMAL TIBIA; FOLLOW-UP; REVISION; COMPONENT; FIXATION; MALALIGNMENT; FAILURE;
D O I
10.1016/j.arth.2021.01.049
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Patients with a preoperative varus deformity >8 degrees are at increased risk of aseptic loosening after total knee arthroplasty. This study analyzes the effect of a tibial stem on the rate of aseptic loosening in patients with a severe preoperative varus deformity. Methods: Patients with a preoperative varus deformity of >8 degrees and 2-year minimum follow-up with a stemmed tibial component (n = 67) were matched 1:2 to patients with a similar preoperative varus deformity with a standard tibial component (n = 134). Radiolucent lines were measured on the tibia at 6 weeks, 1 year, and 2 years postoperatively using the Knee Society Radiographic Evaluation System. Failure was defined as revision due to aseptic loosening of the tibial component. Outcomes were evaluated using Student's t-tests and log-rank tests. Results: Patients with tibial stems had greater preoperative deformity (12.9 vs 11.3 degrees, P = .004). There was no difference in postoperative alignment (1.7 vs 2.1 degrees varus, P = .25) or tibial component angle (1.8 vs 2.1 degrees varus, P = .33). Patients with stems were more likely to have more constraint (44.8% vs 1.5%, P <.001). Progression of radiolucent lines >2 mmwas observed in 17.6% (23/134) vs 5.97% (4/67) of patients in the stem group (P = .03). Rates of aseptic loosening were lower in the stem group (0% vs 5.15%, P = .05). Conclusion: Despite worse preoperative deformity and higher utilization of constraint, tibial stem use in patients with severe preoperative varus deformity resulted in lower rates of aseptic loosening. Prophylactic use of stems in these patients may help increase implant survival. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页码:2319 / 2324
页数:6
相关论文
共 50 条
  • [41] Aseptic loosening of the option stemmed tibial tray in the Zimmer NexGen LPS total knee arthroplasty system
    Bhalekar, Rohan M.
    Wells, Stephen R.
    Nargol, Matthew E.
    Shariatpanahi, Shahrzad
    Nargol, Antoni V. F.
    Waller, Susan
    Wildberg, Linda
    Tilley, Simon
    Langton, David J.
    KNEE, 2024, 47 : 1 - 12
  • [42] A Novel Percentage-Based System for Determining Aseptic Loosening of Total Knee Arthroplasty Tibial Components
    Chalmers, Brian P.
    Sculco, Peter K.
    Fehring, Keith A.
    Trousdale, Robert T.
    Taunton, Michael J.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (07): : 2274 - 2278
  • [43] Early aseptic loosening and inferior patient-reported outcomes of a cementless tibial baseplate in a modern total knee arthroplasty design
    Andronic, O.
    Yang, Y. H.
    Jones, C. W.
    Yates, P. J.
    BONE & JOINT JOURNAL, 2025, 107B (04): : 440 - 448
  • [44] The Effect of Postoperative Mild Varus Deformity on Functional Outcome Scores after Primary Total Knee Arthroplasty in Patients with Varus Osteoarthritis
    Ekinci, Mehmet
    Ersin, Mehmet
    Demirel, Mehmet
    Yilmaz, Murat
    ISTANBUL MEDICAL JOURNAL, 2022, 23 (02): : 125 - 130
  • [45] Stemmed Versus Nonstemmed Tibia in Primary Total Knee Arthroplasty: A Similar Pattern of Aseptic Tibial Loosening in Obese Patients with Moderate Varus. 5-Year Outcomes of a Randomized Controlled Trial
    Mohammad, Molham M.
    Elesh, Mohammed M.
    El-Desouky, Ihab I.
    JOURNAL OF KNEE SURGERY, 2023, 36 (12) : 1266 - 1272
  • [46] REVISION TOTAL HIP ARTHROPLASTY IN PATIENTS WITH ASEPTIC LOOSENING OF FEMORAL STEM (REVIEW)
    Sementkovsky, A. V.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2011, (01): : 153 - 159
  • [47] Changes in hindfoot alignment after total knee arthroplasty in knee osteoarthritic patients with varus deformity
    Woo-Shin Cho
    Hun-Sik Cho
    Seong-Eun Byun
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 3596 - 3604
  • [48] Radiological and Functional Outcome of Medial Tibial Reduction Osteotomy for Severe Varus Deformity in patients undergoing Total Knee Arthroplasty- A Prospective Cohort Study
    Mathew, Amal
    Kumar, A. S. Arun
    Babu, Murukan
    Ranjith, T. C.
    John, Susan
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (06)
  • [49] HEALTH CARE RESOURCE UTILIZATION AND COSTS AMONG PATIENTS WITH ASEPTIC LOOSENING AFTER PRIMARY TOTAL KNEE ARTHROPLASTY
    Chitnis, A. S.
    Yadalam, S.
    DoRego, B.
    Dwyer, K.
    Funk, D.
    Holy, C. E.
    Nunley, R. M.
    VALUE IN HEALTH, 2018, 21 : S268 - S268
  • [50] Changes in hindfoot alignment after total knee arthroplasty in knee osteoarthritic patients with varus deformity
    Cho, Woo-Shin
    Cho, Hun-Sik
    Byun, Seong-Eun
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (11) : 3596 - 3604