A Prophylactic Tibial Stem Reduces Rates of Early Aseptic Loosening in Patients with Severe Preoperative Varus Deformity in Primary Total Knee Arthroplasty

被引:9
|
作者
Hegde, Vishal [1 ,2 ]
Bracey, Daniel N. [1 ,3 ]
Brady, Anna C. [1 ]
Kleeman-Forsthuber, Lindsay T. [1 ]
Dennis, Douglas A. [1 ,4 ,5 ,6 ]
Jennings, Jason M. [1 ,4 ]
机构
[1] Colorado Joint Replacement, 2535 S Downing St,Suite 100, Denver, CO 80210 USA
[2] Johns Hopkins Univ, Dept Orthopaed Surg, Baltimore, MD USA
[3] Univ N Carolina, Dept Orthopaed Surg, Chapel Hill, NC 27515 USA
[4] Univ Denver, Dept Mech & Mat Engn, Denver, CO USA
[5] Univ Colorado, Sch Med, Dept Orthopaed, Denver, CO USA
[6] Univ Tennessee, Dept Biomed Engn, Knoxville, TN USA
来源
JOURNAL OF ARTHROPLASTY | 2021年 / 36卷 / 07期
关键词
varus deformity; total knee arthroplasty; tibial stem extension; aseptic loosening; preoperative alignment; PROXIMAL TIBIA; FOLLOW-UP; REVISION; COMPONENT; FIXATION; MALALIGNMENT; FAILURE;
D O I
10.1016/j.arth.2021.01.049
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Patients with a preoperative varus deformity >8 degrees are at increased risk of aseptic loosening after total knee arthroplasty. This study analyzes the effect of a tibial stem on the rate of aseptic loosening in patients with a severe preoperative varus deformity. Methods: Patients with a preoperative varus deformity of >8 degrees and 2-year minimum follow-up with a stemmed tibial component (n = 67) were matched 1:2 to patients with a similar preoperative varus deformity with a standard tibial component (n = 134). Radiolucent lines were measured on the tibia at 6 weeks, 1 year, and 2 years postoperatively using the Knee Society Radiographic Evaluation System. Failure was defined as revision due to aseptic loosening of the tibial component. Outcomes were evaluated using Student's t-tests and log-rank tests. Results: Patients with tibial stems had greater preoperative deformity (12.9 vs 11.3 degrees, P = .004). There was no difference in postoperative alignment (1.7 vs 2.1 degrees varus, P = .25) or tibial component angle (1.8 vs 2.1 degrees varus, P = .33). Patients with stems were more likely to have more constraint (44.8% vs 1.5%, P <.001). Progression of radiolucent lines >2 mmwas observed in 17.6% (23/134) vs 5.97% (4/67) of patients in the stem group (P = .03). Rates of aseptic loosening were lower in the stem group (0% vs 5.15%, P = .05). Conclusion: Despite worse preoperative deformity and higher utilization of constraint, tibial stem use in patients with severe preoperative varus deformity resulted in lower rates of aseptic loosening. Prophylactic use of stems in these patients may help increase implant survival. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页码:2319 / 2324
页数:6
相关论文
共 50 条
  • [1] Increased Rates of Tibial Aseptic Loosening in Primary Cemented Total Knee Arthroplasty With a Short Native Tibial Stem Design
    Garceau, Simon P.
    Pivec, Robert
    Teo, Greg
    Chisari, Emanuele
    Enns, Paul A.
    Weinblatt, Aaron, I
    Aggarwal, Vinay K.
    Austin, Matthew S.
    Long, William J.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2022, 30 (07) : E640 - E648
  • [2] Modular Tibial Stem Use and Risk of Revision for Aseptic Loosening in Cemented Primary Total Knee Arthroplasty
    Hinman, Adrian D.
    Prentice, Heather A.
    Paxton, Elizabeth W.
    Kelly, Matthew P.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (05): : 1577 - 1583
  • [3] Early aseptic loosening of primary total knee arthroplasty in patients with osteonecrosis of the knee: A case series
    Baek, Ji-Hoon
    Lee, Su Chan
    Ryu, Suengryol
    Ahn, Hye Sun
    Nam, Chang Hyun
    CLINICAL CASE REPORTS, 2022, 10 (12):
  • [4] PRIMARY TOTAL KNEE ARTHROPLASTY IN PATIENTS WITH SEVERE VARUS DEFORMITY - A COMPARATIVE-STUDY
    TEENY, SM
    KRACKOW, KA
    HUNGERFORD, DS
    JONES, M
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1991, (273) : 19 - 31
  • [5] Total Ankle Arthroplasty With Severe Preoperative Varus Deformity
    Hanselman, Andrew E.
    Powell, Brian D.
    Santrock, Robert D.
    ORTHOPEDICS, 2015, 38 (04) : E343 - E346
  • [6] Correction of severe varus deformity in total knee arthroplasty with the technique of tibial plateau reduction
    Zha, Guo-Chun
    Bao, Gang
    Wu, Hao
    Wang, He-Ping
    Wang, An-Dong
    Shen, Zhi-Jun
    KNEE, 2025, 53 : 138 - 146
  • [7] Aseptic Tibial Implant Loosening After Total Knee Arthroplasty: Preventable?
    Menken, Luke G.
    Fleuriscar, Jean
    Weiner, Travis
    Berliner, Zachary P.
    Rodriguez, Jose A.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2021, 29 (08) : 326 - 330
  • [8] Is cement mantle thickness a primary cause of aseptic tibial loosening following primary total knee arthroplasty?
    Cox, Zach C.
    Engstrom, Stephen M.
    Shinar, Andrew A.
    Polkowski, Gregory G.
    Mason, J. Bohannon
    Martin, J. Ryan
    KNEE, 2023, 40 : 305 - 312
  • [9] Mini-Midvastus Total Knee Arthroplasty in Patients With Severe Varus Deformity
    Liu, Hao-Chen
    Kuo, Feng-Chih
    Huang, Chung-Chen
    Wang, Jun-Wen
    ORTHOPEDICS, 2015, 38 (02) : E112 - E117
  • [10] Correction of varus deformity with tibial flip autograft technique in total knee arthroplasty
    Franceschina, MJ
    Swienckowski, JJ
    JOURNAL OF ARTHROPLASTY, 1999, 14 (02): : 172 - 174