Reliability and validity of using the Lokomat to assess lower limb joint position sense in people with incomplete spinal cord injury

被引:35
|
作者
Domingo, Antoinette [1 ,2 ]
Lam, Tania [1 ,2 ]
机构
[1] Univ British Columbia, Sch Kinesiol, Vancouver, BC V5Z 1M9, Canada
[2] Int Collaborat Repair Discoveries ICORD, Vancouver, BC, Canada
基金
加拿大健康研究院;
关键词
PROPRIOCEPTION; HIP; KNEE; INDEPENDENCE; PATIENT; WALKING; STROKE; ANKLE; SWAY;
D O I
10.1186/1743-0003-11-167
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Proprioceptive sense (knowing where the limbs are in space) is critical for motor control during posture and walking, and is often compromised after spinal cord injury (SCI). The purpose of this study was to assess the reliability and validity of using the Lokomat, a robotic exoskeleton used for gait rehabilitation, to quantitatively measure static position sense of the legs in persons with incomplete SCI. Methods: We used the Lokomat and custom software to assess static position sense in 23 able-bodied (AB) subjects and 23 persons with incomplete SCI (American Spinal Injury Association Impairment Scale level B, C or D). The subject's leg was placed into a target position (joint angle) at either the hip or knee and asked to memorize that position. The Lokomat then moved the test joint to a "distractor" position. The subject then used a joystick controller to bring the joint back into the memorized target position. The final joint angle was compared to the target angle and the absolute difference was recorded as an error. All movements were passive. Known-groups validity was determined by the ability of the measure to discriminate between able-bodied and SCI subjects. To evaluate test-retest reliability, subjects were tested twice and intra-class correlation coefficients comparing errors from the two sessions were calculated. We also performed a traditional clinical test of proprioception in subjects with SCI and compared these scores to the robotic assessment. Results: The robot-based assessment test was reliable at the hip and knee in persons with SCI (P <= 0.001). Hip and knee angle errors in subjects with SCI were significantly greater (P <= 0.001) and more variable (P < 0.0001) than in AB subjects. Error scores were significantly correlated to clinical measure of joint position sense (r >= 0.507, P <= 0.013). Conclusions: This study shows that the Lokomat may be used as a reliable and valid clinical measurement tool for assessing joint position sense in persons with incomplete SCI. Quantitative assessments of proprioceptive deficits after neurological injury will help in understanding its role in the recovery of skilled walking and in the development of interventions to aid in the return to safe community ambulation.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Reliability and validity of using the Lokomat to assess lower limb joint position sense in people with incomplete spinal cord injury
    Antoinette Domingo
    Tania Lam
    [J]. Journal of NeuroEngineering and Rehabilitation, 11
  • [2] Lower limb joint position sense and prospective hamstring injury
    Smith, Nigel A.
    Cameron, Matt
    Treleaven, Julia
    Hides, Julie A.
    [J]. MUSCULOSKELETAL SCIENCE AND PRACTICE, 2021, 53
  • [3] Reliability and Validity of the Functional Gait Assessment in Incomplete Spinal Cord Injury
    Kahn, Jennifer H.
    Ohlendorf, April
    Olsen, Alison
    Gordon, Keith E.
    [J]. TOPICS IN SPINAL CORD INJURY REHABILITATION, 2020, 26 (04) : 268 - 274
  • [4] Neurophysiological assessment of lower-limb voluntary control in incomplete spinal cord injury
    H K Lim
    D C Lee
    W B McKay
    M M Priebe
    S A Holmes
    A M Sherwood
    [J]. Spinal Cord, 2005, 43 : 283 - 290
  • [5] Neurophysiological assessment of lower-limb voluntary control in incomplete spinal cord injury
    Lim, HK
    Lee, DC
    McKay, WB
    Priebe, MM
    Holmes, SA
    Sherwood, AM
    [J]. SPINAL CORD, 2005, 43 (05) : 283 - 290
  • [6] Validity and Reliability of a Digital Inclinometer to Assess Knee Joint Position Sense in an Open Kinetic Chain
    Romero-Franco, Natalia
    Antonio Montano-Munuera, Juan
    Carlos Fernandez-Dominguez, Juan
    Jimenez-Reyes, Pedro
    [J]. JOURNAL OF SPORT REHABILITATION, 2019, 28 (04) : 332 - 338
  • [7] Proposal for Clinical Validation of Lower Limb Robotic Exoskeleton in Patients with Incomplete Spinal Cord Injury
    Perez-Nombela, Soraya
    del-Ama, Antonio J.
    Gil-Agudo, Angel
    Alcobendas-Maestro, Monica
    Lopez-Diaz, Fernando
    Benito-Penalva, Jesus
    Pons, Jose L.
    Moreno, Juan C.
    [J]. CONVERGING CLINICAL AND ENGINEERING RESEARCH ON NEUROREHABILITATION II, VOLS 1 AND 2, 2017, 15 : 1439 - 1443
  • [8] Reliability and validity of lower limb joint range of motion measurements using a smartphone
    Miyachi, Yousuke
    Ito, Morihiro
    Furuta, Kunihiro
    Ban, Rua
    Hanamura, Shuntaro
    Kamiya, Mitsuhiro
    [J]. NAGOYA JOURNAL OF MEDICAL SCIENCE, 2022, 84 (01): : 7 - 18
  • [9] Validity and Reliability of Assessment Tools for Measuring Unsupported Sitting in People With a Spinal Cord Injury
    Boswell-Ruys, Claire L.
    Sturnieks, Daina L.
    Harvey, Lisa A.
    Sherrington, Catherine
    Middleton, James W.
    Lord, Stephen R.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2009, 90 (09): : 1571 - 1577
  • [10] Diagnostic tests to assess balance in patients with spinal cord injury: a systematic review of their validity and reliability
    Arsh, Aatik
    Darain, Haider
    Ullah, Irfan
    Shakil-ur-Rehman, Syed
    [J]. ASIAN BIOMEDICINE, 2021, 15 (03) : 111 - 118