Reliability and validity of using the Lokomat to assess lower limb joint position sense in people with incomplete spinal cord injury

被引:35
|
作者
Domingo, Antoinette [1 ,2 ]
Lam, Tania [1 ,2 ]
机构
[1] Univ British Columbia, Sch Kinesiol, Vancouver, BC V5Z 1M9, Canada
[2] Int Collaborat Repair Discoveries ICORD, Vancouver, BC, Canada
基金
加拿大健康研究院;
关键词
PROPRIOCEPTION; HIP; KNEE; INDEPENDENCE; PATIENT; WALKING; STROKE; ANKLE; SWAY;
D O I
10.1186/1743-0003-11-167
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Proprioceptive sense (knowing where the limbs are in space) is critical for motor control during posture and walking, and is often compromised after spinal cord injury (SCI). The purpose of this study was to assess the reliability and validity of using the Lokomat, a robotic exoskeleton used for gait rehabilitation, to quantitatively measure static position sense of the legs in persons with incomplete SCI. Methods: We used the Lokomat and custom software to assess static position sense in 23 able-bodied (AB) subjects and 23 persons with incomplete SCI (American Spinal Injury Association Impairment Scale level B, C or D). The subject's leg was placed into a target position (joint angle) at either the hip or knee and asked to memorize that position. The Lokomat then moved the test joint to a "distractor" position. The subject then used a joystick controller to bring the joint back into the memorized target position. The final joint angle was compared to the target angle and the absolute difference was recorded as an error. All movements were passive. Known-groups validity was determined by the ability of the measure to discriminate between able-bodied and SCI subjects. To evaluate test-retest reliability, subjects were tested twice and intra-class correlation coefficients comparing errors from the two sessions were calculated. We also performed a traditional clinical test of proprioception in subjects with SCI and compared these scores to the robotic assessment. Results: The robot-based assessment test was reliable at the hip and knee in persons with SCI (P <= 0.001). Hip and knee angle errors in subjects with SCI were significantly greater (P <= 0.001) and more variable (P < 0.0001) than in AB subjects. Error scores were significantly correlated to clinical measure of joint position sense (r >= 0.507, P <= 0.013). Conclusions: This study shows that the Lokomat may be used as a reliable and valid clinical measurement tool for assessing joint position sense in persons with incomplete SCI. Quantitative assessments of proprioceptive deficits after neurological injury will help in understanding its role in the recovery of skilled walking and in the development of interventions to aid in the return to safe community ambulation.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Test-retest reliability and validity of the Sitting Balance Measure-Korean in individuals with incomplete spinal cord injury
    Lee, JunMin
    An, SeungHeon
    Kim, OnYoo
    Kang, GyuMin
    Kim, Myungki
    [J]. SPINAL CORD, 2022, 60 (07) : 641 - 646
  • [22] Reliability and validity of the six-minute arm test for the evaluation of cardiovascular fitness in people with spinal cord injury
    Hol, Adrienne T.
    Eng, Janice J.
    Miller, William C.
    Sproule, Shannon
    Krassioukov, Andrei V.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (04): : 489 - 495
  • [23] THE EFFECT OF USING LOWER LIMB ORTHOSES ON BONE MINERAL CONTENT IN SUBJECTS WITH SPINAL CORD INJURY
    Bani, M. Ahmadi
    [J]. OSTEOPOROSIS INTERNATIONAL, 2018, 29 : S208 - S208
  • [24] Acute suppression of lower limb spasm by sacral afferent stimulation for people with spinal cord injury: A pilot study
    Massey, Sarah
    Doherty, Sean
    Duffell, Lynsey
    Craggs, Mike
    Knight, Sarah
    [J]. WEARABLE TECHNOLOGIES, 2024, 5
  • [25] Correspondence to “Test-retest reliability and validity of the Sitting Balance Measure-Korean in individuals with incomplete spinal cord injury”
    Libak Abou
    [J]. Spinal Cord, 2022, 60 : 763 - 763
  • [26] Correspondence to "Test-retest reliability and validity of the Sitting Balance Measure-Korean in individuals with incomplete spinal cord injury"
    Abou, Libak
    [J]. SPINAL CORD, 2022, 60 (08) : 763 - 763
  • [27] Assessing lower limb position sense in stroke using the gradient discrimination test (GradDT™) and step-height discrimination test (StepDT™): a reliability and validity study
    Gorst, Terry
    Freeman, Jenny
    Yarrow, Kielan
    Marsden, Jonathan
    [J]. DISABILITY AND REHABILITATION, 2020, 42 (15) : 2215 - 2223
  • [28] Reliability of the clinical outcome variables scale when administered via telephone to assess mobility in people with spinal cord injury
    Barker, Ruth N.
    Amsters, Delena I.
    Kendall, Melissa D.
    Pershouse, Kiley J.
    Haines, Terry P.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (05): : 632 - 637
  • [29] The Neurogenic Bladder Symptom Score (NBSS): a secondary assessment of its validity, reliability among people with a spinal cord injury
    Blayne Welk
    Sara Lenherr
    Sean Elliott
    John Stoffel
    Angela P. Presson
    Chong Zhang
    Jeremy B. Myers
    [J]. Spinal Cord, 2018, 56 : 259 - 264
  • [30] The Neurogenic Bladder Symptom Score (NBSS): a secondary assessment of its validity, reliability among people with a spinal cord injury
    Welk, Blayne
    Lenherr, Sara
    Elliott, Sean
    Stoffel, John
    Presson, Angela P.
    Zhang, Chong
    Myers, Jeremy B.
    [J]. SPINAL CORD, 2018, 56 (03) : 259 - 264