Systematic verification of a three-dimensional electron beam dose calculation algorithm

被引:37
|
作者
Cheng, A
Harms, WB
Gerber, RL
Wong, JW
Purdy, JA
机构
[1] Mallinckrodt Institute of Radiology, Washington University, School of Medicine, St. Louis
[2] William Beaumont Hospital, Royal Oak
关键词
electron beams; 3D radiation treatment planning; pencil beam calculation; algorithm verification;
D O I
10.1118/1.597714
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A three-dimensional electron beam dose calculation algorithm implemented on a commercial radiotherapy treatment planning system is described. The calculation is based on the M. D. Anderson Hospital (M.D.A.H.) pencil beam model, which uses the Fermi-Eyges theory of thick-target multiple Coulomb scattering. To establish the calculation algorithm's accuracy as well as its limitations, it was systematically and extensively tested and evaluated against a set of benchmark measurements. Various levels of dose and spatial tolerances were used to validate the calculation quantitatively. Results are presented in terms of the percentage of data points meeting a specific tolerance level. The algorithm's ability to accurately simulate commonly used clinical setup geometries, including standard or extended SSDs, blocked fields, irregular surfaces, and heterogeneities, is demonstrated. Regions of disagreement between calculations and measurements are also shown. The clinical implication of such disagreements is addressed, and the algorithmic assumptions involved are discussed. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:685 / 693
页数:9
相关论文
共 50 条
  • [21] Three-dimensional additive electron-beam lithography
    Koops, HWP
    Weber, M
    Schossler, C
    Kaja, A
    METAL/NONMETAL MICROSYSTEMS: PHYSICS, TECHNOLOGY, AND APPLICATIONS, 1996, 2780 : 388 - 395
  • [22] Three-dimensional model of electron beam generated plasma
    Rauf, Shahid
    Balakrishna, Ajit
    Agarwal, Ankur
    Dorf, Leonid
    Collins, Kenneth
    Boris, David R.
    Walton, Scott G.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2017, 26 (06):
  • [23] Three-dimensional simulation study on the electron beam lithography
    Song, Hui-Ying
    Yang, Rui
    Zhao, Zhen-Yu
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2010, 38 (03): : 617 - 619
  • [24] An Inverse Dose Optimization Algorithm for Three-Dimensional Brachytherapy
    Wang, Xianliang
    Wang, Pei
    Tang, Bin
    Kang, Shengwei
    Hou, Qing
    Wu, Zhangwen
    Gou, Chengjun
    Li, Lintao
    Orlandini, Lucia
    Lang, Jinyi
    Li, Jie
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [25] An Inverse Dose Optimization Algorithm for Three-Dimensional Brachytherapy
    Wang, X.
    Li, J.
    Wang, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E307 - E307
  • [26] Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM
    Francescon, P
    Cavedon, C
    Reccanello, S
    Cora, S
    MEDICAL PHYSICS, 2000, 27 (07) : 1579 - 1587
  • [27] Three-dimensional versus four-dimensional dose calculation for breast IMRT
    Chung, J.
    Chun, M.
    Park, J. M.
    Kim, J.
    Shin, K.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S703 - S703
  • [28] Long-term stability of a three-dimensional dose verification system
    Motoharu Sasaki
    Hitoshi Ikushima
    Wataru Sugimoto
    Kenta Kitagawa
    Radiological Physics and Technology, 2020, 13 : 83 - 91
  • [29] Inclusion type radiochromic gel dosimeter for three-dimensional dose verification
    Usui, Shuji
    Yoshioka, Munenori
    Hayashi, Shin-ichiro
    Tominaga, Takahiro
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [30] dosimetric properties and dose verification of a new three-dimensional detector array
    Yang, Xin
    Shen, Zhengwen
    Feng, Bin
    Jin, Fu
    Luo, Huanli
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3363 - S3365