An Inverse Dose Optimization Algorithm for Three-Dimensional Brachytherapy

被引:4
|
作者
Wang, Xianliang [1 ]
Wang, Pei [1 ]
Tang, Bin [1 ]
Kang, Shengwei [1 ]
Hou, Qing [2 ]
Wu, Zhangwen [2 ]
Gou, Chengjun [2 ]
Li, Lintao [1 ]
Orlandini, Lucia [1 ]
Lang, Jinyi [1 ]
Li, Jie [1 ]
机构
[1] Univ Elect Sci & Technol China, Radiat Oncol Key Lab Sichuan Prov, Dept Radiat Oncol, Sichuan Canc Hosp & Inst,Sch Med, Chengdu, Peoples R China
[2] Sichuan Univ, Inst Nucl Sci & Technol, Key Lab Radiat Phys & Technol, Chengdu, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2020年 / 10卷
关键词
brachytherapy; inverse optimization; cervical cancer; treatment planning system; dwell time; GEC-ESTRO; ANATOMY;
D O I
10.3389/fonc.2020.564580
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose To investigate an implementation method and the results of an inverse dose optimization algorithm, Gradient Based Planning Optimization (GBPO), for three-dimensional brachytherapy. Methods The GBPO used a quadratic objective function, and a dwell time modulation item was added to the objective function to restrict the dwell time variance. We retrospectively studied 4 cervical cancer patients using different applicators and 15 cervical cancer patients using the Fletcher applicator. We assessed the plan quality of GBPO by isodose lines for the patients using different applicators. For the 15 patients using the Fletcher applicator, we utilized dose-volume histogram (DVH) parameters of HR-CTV (D-100%, V-150%) and organs at risk (OARs) (D-0.1cc, D-1cc, D-2cc) to evaluate the difference between the GBPO plans and the IPSA (Inverse Planning Simulated Annealing) plans, as well as the GBPO plans and the Graphic plans. Results For the 4 patients using different applicators, the dose distributions are conformable. For the 15 patients using the Fletcher applicator, when the dwell time modulation factor (DTMF) is less than 20, the dwell time deviation reduces quickly; however, after the DTMF increased to 100, the dwell time deviation has no remarkable change. The difference in dosimetric parameters between the GBPO plans and the IPSA plans is not statistically significant (P0.05). The GBPO plans have a higher D-100% (3.57 +/- 0.36, 3.38 +/- 0.34; P0.01) and a lower V-150% (55.73 +/- 4.06, 57.75 +/- 3.79; P0.01) than those of the Graphic plans. The differences in other DVH parameters are negligible between the GBPO plans and the Graphic plans. Conclusions The GBPO plans have a comparable quality as the IPSA plans and the Graphic plans for the studied cervical cancer cases. The GBPO algorithm could be integrated into a three-dimensional brachytherapy treatment planning system after studying more sites.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] An Inverse Dose Optimization Algorithm for Three-Dimensional Brachytherapy
    Wang, X.
    Li, J.
    Wang, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E307 - E307
  • [2] Three-Dimensional Conformal Dose Planning for Prostate Brachytherapy
    Shihui Zhang
    Shan Jiang
    Zhiyong Yang
    Zhi Li
    Transactions of Tianjin University, 2018, (01) : 73 - 81
  • [3] Three-Dimensional Conformal Dose Planning for Prostate Brachytherapy
    Shihui Zhang
    Shan Jiang
    Zhiyong Yang
    Zhi Li
    Transactions of Tianjin University, 2018, 24 (01) : 73 - 81
  • [4] Three-Dimensional Conformal Dose Planning for Prostate Brachytherapy
    Zhang S.
    Jiang S.
    Yang Z.
    Li Z.
    Transactions of Tianjin University, 2018, 24 (1) : 73 - 81
  • [5] Three dimensional dose distribution in pulsed dose rate oropharyngeal brachytherapy:: comparison of 3 methods:: non optimization, dose point optimization and inverse optimization
    Ahmad, F
    Lapeyre, M
    Forestier, S
    Brunaud, C
    Aletti, F
    Marchesi, V
    Peiffert, D
    Hoffstetter, S
    Noël, A
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S88 - S88
  • [6] Generation of uniformly distributed dose points for anatomy-based three-dimensional dose optimization methods in brachytherapy
    Lahanas, M
    Baltas, D
    Giannouli, S
    Milickovic, N
    Zamboglou, N
    MEDICAL PHYSICS, 2000, 27 (05) : 1034 - 1046
  • [7] Anatomy-based three-dimensional dose optimization in brachytherapy using multiobjective genetic algorithms
    Lahanas, M
    Baltas, D
    Zamboglou, N
    MEDICAL PHYSICS, 1999, 26 (09) : 1904 - 1918
  • [8] Realization of Three-Dimensional Conformal Dose Planning in Prostate Brachytherapy
    Li, Z.
    Jiang, S.
    Yang, Z.
    Bai, H.
    Zhang, X.
    MEDICAL PHYSICS, 2014, 41 (06) : 288 - 288
  • [9] Three-dimensional inverse method for aerodynamic optimization in compressor
    Yang, W.
    6TH INTERNATIONAL CONFERENCE ON PUMPS AND FANS WITH COMPRESSORS AND WIND TURBINES (ICPF2013), 2013, 52
  • [10] Three-dimensional endovascular brachytherapy
    Quast, U
    Flühs, D
    Bambynek, M
    Baumgart, D
    von Birgelen, C
    THREE-DIMENSIONAL RADIATION TREATMENT: TECHNOLOGICAL INNOVATIONS AND CLINICAL RESULTS, 2000, 34 : 49 - 58