Three dimensional dose distribution in pulsed dose rate oropharyngeal brachytherapy:: comparison of 3 methods:: non optimization, dose point optimization and inverse optimization

被引:0
|
作者
Ahmad, F
Lapeyre, M
Forestier, S
Brunaud, C
Aletti, F
Marchesi, V
Peiffert, D
Hoffstetter, S
Noël, A
机构
[1] Ctr Alexis Vautrin, Radiophys Unit, Nancy, France
[2] Ctr Alexis Vautrin, Brachytherapy Unit, Nancy, France
[3] INPL, CRAN, CNRS, UMR 7039, Nancy, France
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
192
引用
收藏
页码:S88 / S88
页数:1
相关论文
共 50 条
  • [1] An Inverse Dose Optimization Algorithm for Three-Dimensional Brachytherapy
    Wang, Xianliang
    Wang, Pei
    Tang, Bin
    Kang, Shengwei
    Hou, Qing
    Wu, Zhangwen
    Gou, Chengjun
    Li, Lintao
    Orlandini, Lucia
    Lang, Jinyi
    Li, Jie
    [J]. FRONTIERS IN ONCOLOGY, 2020, 10
  • [2] An Inverse Dose Optimization Algorithm for Three-Dimensional Brachytherapy
    Wang, X.
    Li, J.
    Wang, P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E307 - E307
  • [3] Influence of dose point and inverse optimization on interstitial cervical and oropharyngeal carcinoma brachytherapy
    Ahmad, F
    Aletti, P
    Charra-Brunaud, C
    Van der Laarse, R
    Lapeyre, M
    Hoffstetter, S
    Peiffert, D
    Nöel, A
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 (03) : 331 - 337
  • [4] CT based dose distribution and optimization for gynaecological pulsed dose rate interstitial brachytherapy
    Brunaud, C
    Ahmad, F
    Peiffert, D
    Metayer, Y
    Aletti, P
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S78 - S78
  • [5] OPTIMIZATION OF HIGH DOSE-RATE CERVIX BRACHYTHERAPY .1. DOSE DISTRIBUTION
    HOUDEK, PV
    SCHWADE, JG
    ABITBOL, AA
    PISCIOTTA, V
    WU, XD
    SERAGO, CF
    MARKOE, AM
    LEWIN, AA
    AVERETTE, HE
    SEVIN, BU
    BRANDON, AH
    FIEDLER, JA
    COHEN, AM
    FAYAD, F
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (06): : 1621 - 1625
  • [6] Comparison of dose and catheter optimization algorithms in prostate high-dose-rate brachytherapy
    Poulin, Eric
    Varfalvy, Nicolas
    Aubin, Sylviane
    Beaulieu, Luc
    [J]. BRACHYTHERAPY, 2016, 15 (01) : 102 - 111
  • [7] Generation of uniformly distributed dose points for anatomy-based three-dimensional dose optimization methods in brachytherapy
    Lahanas, M
    Baltas, D
    Giannouli, S
    Milickovic, N
    Zamboglou, N
    [J]. MEDICAL PHYSICS, 2000, 27 (05) : 1034 - 1046
  • [8] Evaluation of anatomy-based dwell position and inverse optimization in high-dose-rate brachytherapy of prostate cancer: a dosimetric comparison to a conventional cylindrical dwell position, geometric optimization, and dose-point optimization
    Yoshioka, Y
    Nishimura, T
    Kamata, M
    Harada, H
    Kanazawa, K
    Fuji, H
    Murayama, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 75 (03) : 311 - 317
  • [9] High Dose Rate Brachytherapy Optimization Based on the Generalized Equivalent Uniform Dose
    Giantsoudi, D.
    Baltas, D.
    Karabis, A.
    Mavroidis, P.
    Shi, C.
    Papanikolaou, N.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [10] HIGH DOSE RATE BRACHYTHERAPY OPTIMIZATION BASED ON THE GENERALIZED EQUIVALENT UNIFORM DOSE
    Giantsoudi, D.
    Baltas, D.
    Karabis, A.
    Mavroidis, P.
    Shi, C.
    Papanikolaou, N.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S40 - S41