An Inverse Dose Optimization Algorithm for Three-Dimensional Brachytherapy

被引:4
|
作者
Wang, Xianliang [1 ]
Wang, Pei [1 ]
Tang, Bin [1 ]
Kang, Shengwei [1 ]
Hou, Qing [2 ]
Wu, Zhangwen [2 ]
Gou, Chengjun [2 ]
Li, Lintao [1 ]
Orlandini, Lucia [1 ]
Lang, Jinyi [1 ]
Li, Jie [1 ]
机构
[1] Univ Elect Sci & Technol China, Radiat Oncol Key Lab Sichuan Prov, Dept Radiat Oncol, Sichuan Canc Hosp & Inst,Sch Med, Chengdu, Peoples R China
[2] Sichuan Univ, Inst Nucl Sci & Technol, Key Lab Radiat Phys & Technol, Chengdu, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2020年 / 10卷
关键词
brachytherapy; inverse optimization; cervical cancer; treatment planning system; dwell time; GEC-ESTRO; ANATOMY;
D O I
10.3389/fonc.2020.564580
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose To investigate an implementation method and the results of an inverse dose optimization algorithm, Gradient Based Planning Optimization (GBPO), for three-dimensional brachytherapy. Methods The GBPO used a quadratic objective function, and a dwell time modulation item was added to the objective function to restrict the dwell time variance. We retrospectively studied 4 cervical cancer patients using different applicators and 15 cervical cancer patients using the Fletcher applicator. We assessed the plan quality of GBPO by isodose lines for the patients using different applicators. For the 15 patients using the Fletcher applicator, we utilized dose-volume histogram (DVH) parameters of HR-CTV (D-100%, V-150%) and organs at risk (OARs) (D-0.1cc, D-1cc, D-2cc) to evaluate the difference between the GBPO plans and the IPSA (Inverse Planning Simulated Annealing) plans, as well as the GBPO plans and the Graphic plans. Results For the 4 patients using different applicators, the dose distributions are conformable. For the 15 patients using the Fletcher applicator, when the dwell time modulation factor (DTMF) is less than 20, the dwell time deviation reduces quickly; however, after the DTMF increased to 100, the dwell time deviation has no remarkable change. The difference in dosimetric parameters between the GBPO plans and the IPSA plans is not statistically significant (P0.05). The GBPO plans have a higher D-100% (3.57 +/- 0.36, 3.38 +/- 0.34; P0.01) and a lower V-150% (55.73 +/- 4.06, 57.75 +/- 3.79; P0.01) than those of the Graphic plans. The differences in other DVH parameters are negligible between the GBPO plans and the Graphic plans. Conclusions The GBPO plans have a comparable quality as the IPSA plans and the Graphic plans for the studied cervical cancer cases. The GBPO algorithm could be integrated into a three-dimensional brachytherapy treatment planning system after studying more sites.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] On the role of three-dimensional inverse design methods in turbomachinery shape optimization
    Zangeneh, M.
    Goto, A.
    Harada, H.
    Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering, 1999, 213 (01): : 27 - 42
  • [22] High-dose-rate brachytherapy:: Dose escalation in three-dimensional miniorgans of the human bronchial wall
    Kotsianos, D
    Bach, D
    Gamarra, F
    Haimerl, W
    Knüchel, R
    Lang, SM
    Pfeifer, KJ
    Huber, RM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (05): : 1267 - 1273
  • [23] Knowledge-Based Three-Dimensional Dose Prediction for Tandem-And-Ovoid Brachytherapy
    Cortes, K.
    Simon, A.
    Kallis, K.
    Mayadev, J.
    Meyers, S.
    Moore, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E332 - E332
  • [24] Definitive three-dimensional high-dose-rate brachytherapy for inoperable endometrial cancer
    Draghini, Lorena
    Maranzano, Ernesto
    Casale, Michelina
    Trippa, Fabio
    Anselmo, Paola
    Arcidiacono, Fabio
    Fabiani, Stefania
    Italiani, Marco
    Chirico, Luigia
    Muti, Marco
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2017, 9 (02) : 118 - 123
  • [25] Knowledge-based three-dimensional dose prediction for tandem-and-ovoid brachytherapy
    Cortes, Katherina G.
    Kallis, Karoline
    Simon, Aaron
    Mayadev, Jyoti
    Meyers, Sandra M.
    Moore, Kevin L.
    BRACHYTHERAPY, 2022, 21 (04) : 532 - 542
  • [26] A simple approach to the three-dimensional visualization of three-dimensional calculated brachytherapy treatment plans
    Hebbinghaus, D
    Dennert, P
    Kohr, P
    Kovacs, G
    Kimmig, B
    QUANTITATIVE IMAGING IN ONCOLOGY: 19TH L H GRAY CONFERENCE, 1996, : 99 - 102
  • [27] Simulation and Optimization of Cockpit based on Three-dimensional Localization Algorithm
    Yang, Zheng
    Wu, Qi
    Fu, Shan
    JOURNAL OF AERONAUTICS ASTRONAUTICS AND AVIATION, 2014, 46 (04): : 233 - 239
  • [28] A Three-Dimensional Network Coverage Optimization Algorithm in Healthcare System
    Liu, Xiaoshuang
    Kang, Guixia
    Zhang, Ningbo
    Zhu, Bingning
    Li, Congcong
    Chai, Yi
    Liu, Yuncheng
    2014 IEEE 16TH INTERNATIONAL CONFERENCE ON E-HEALTH NETWORKING, APPLICATIONS AND SERVICES (HEALTHCOM), 2014, : 323 - 328
  • [29] Three-Dimensional Conformal Brachytherapy Applications and Results
    Tokatli, Fusun
    Alkaya, Fadime
    Aksakal, Oznur
    Dincer, Maktav
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2012, 27 (01): : 42 - 44
  • [30] Three-dimensional dosimetry in brachytherapy: A MAGAT study
    Lin, Min-Hsing
    Huang, Tzung-Chi
    Kao, Ming-Jen
    Wu, Jay
    Chen, Chia-Lin
    Wu, Tung-Hsin
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : 1432 - 1437