Experimental study of attenuation properties of normoxic polymer gel dosimeters

被引:53
|
作者
Brindha, S [1 ]
Venning, AJ
Hill, B
Baldock, C
机构
[1] Christian Med Coll & Hosp, Dept Radiat Oncol, Vellore 632004, Tamil Nadu, India
[2] Queensland Univ Technol, Sch Phys & Chem Sci, Brisbane, Qld 4001, Australia
[3] Canberra Hosp, Med Phys Sect, Biomed Engn Serv, Woden, ACT 2606, Australia
[4] Univ Sydney, Inst Med Phys, Sydney, NSW 2006, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2004年 / 49卷 / 20期
关键词
D O I
10.1088/0031-9155/49/20/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The change in linear attenuation coefficient with absorbed dose has been investigated for aqueous polyacrylamide, gelatine and tetrakis (PAGAT) and aqueous methacrylic acid, gelatine and tetrakis (MAGAT) normoxic polymer gel dosimeters using tetrakis (hydroxy methyl) phosphonium chloride as the antioxidant. The measured linear attenuation coefficient increased linearly with absorbed dose up to 15 Gy for PAGAT gels and 10 Gy for MAGAT gels. Computerized tomography (CT) numbers or Hounsfield units (H) were calculated from the linear attenuation coefficients and compared with values obtained using a CT scanner. Both calculated and measured CT numbers followed a similar pattern when fitted with a biexponential curve. The CT numbers obtained from linear attenuation measurements were found to be greater than that obtained with the CT scanner for both PAGAT and MAGAT polymer gels. The H-dose sensitivities of the MAGAT and PAGAT polymer gel dosimeters measured on a CT scanner were calculated to be (0.85 +/- 0.08) H Gy(-1) and (0.31 +/- 0.03) H Gy(-1), respectively. The H-dose sensitivities of the MAGAT and PAGAT polymer gel dosimeters from attenuation measurements were found to be (1.10 +/- 0.66) H Gy(-1) and (0.34 +/- 0.01) H Gy(-1), respectively.
引用
收藏
页码:N353 / N361
页数:9
相关论文
共 50 条
  • [31] An experimental study of the dose response of polymer gel dosimeters imaged with x-ray computed tomography
    Trapp, JV
    Bäck, SÅJ
    Lepage, M
    Michael, G
    Baldock, C
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11): : 2939 - 2951
  • [32] MAGIC - Normoxic polymer gel dosimetry in radiosurgery
    Scheib, SG
    Vogelsanger, W
    RADIOSUGERY, VOL 5, 2004, 5 : 213 - 224
  • [33] Polymer gel dosimeters with PVA–GA matrix
    Seyed Mohammad Mahdi Abtahi
    Hamid Sadeghi Abandansari
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 651 - 658
  • [34] Verification of IMRT using normoxic polymer gel (THP-gel)
    Hysing, LB
    Wasbo, E
    Gustavsson, H
    Karlsson, A
    Andersen, E
    Ersland, L
    Muren, L
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S183 - S184
  • [35] Development of a novd normoxic polymer gel dosimeter (TENOMAG)
    Cho, Sam Ju
    Shin, Dongho
    Do Huh, Hyun
    Lee, Sang Hoon
    Lim, Sang Wook
    Jang, Jisun
    Cho, Kwang Hwan
    Shin, Hun Joo
    Kwon, Sooil
    Yun, Hyong Geun
    Yun, Sang Mo
    Shin, Dong Oh
    Yang, Dae Sik
    Park, Young Je
    Kim, Chul Yong
    Lee, Suk
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 51 (05) : 1798 - 1804
  • [36] Development of a new normoxic polymer gel dosimeter (TENOMAG)
    Lee, S.
    Ch, S.
    Huh, H.
    Lee, S.
    Shin, H.
    Kwon, S.
    Yun, H.
    Yang, D.
    Park, Y.
    Kim, C.
    EJC SUPPLEMENTS, 2007, 5 (04): : 130 - 130
  • [37] Effects of gel composition on the radiation induced density change in PAG polymer gel dosimeters: a model and experimental investigations
    Hilts, M
    Jirasek, A
    Duzenli, C
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12): : 2477 - 2490
  • [38] A Study of Normoxic Polymer Gel using Monomer 2-Hydroxyethyl Methacrylate (HEMA)
    Ishak, Siti Atiqah
    Mustafa, Iskandar Shahrim
    Rahman, Azhar Abdul
    Moktar, Mohd
    Min, Ung Ngie
    NATIONAL PHYSICS CONFERENCE 2014 (PERFIK 2014), 2015, 1657
  • [39] Polymer Gel Dosimeters for use in Targeted Radionuclide Therapy
    Gear, J. I.
    Flux, G. D.
    Partridge, M.
    Ott, R. J.
    Charles-Edwards, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S207 - S207
  • [40] Polymer gel dosimeters with PVA-GA matrix
    Abtahi, Seyed Mohammad Mahdi
    Abandansari, Hamid Sadeghi
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (03) : 651 - 658