Composite Electrodes Based on Carbon Materials Decorated with Hg Nanoparticles for the Simultaneous Detection of Cd(II), Pb(II) and Cu(II)

被引:9
|
作者
Fernandez, Laia L. [1 ,2 ]
Bastos-Arrieta, Julio [3 ]
Palet, Cristina [1 ]
Baeza, Mireia [2 ]
机构
[1] Univ Autonoma Barcelona, Fac Sci, Dept Chem, GTS Res Grp, Edifici C Nord, Bellaterra 08193, Spain
[2] Univ Autonoma Barcelona, Fac Sci, Dept Chem, GENOCOV Res Grp, Edifici C Nord, Bellaterra 08193, Spain
[3] Univ Barcelona, Dept Chem Engn & Analyt Chem, Grp Electroanal, Carrer Marti & Franques 1-11, Barcelona 08028, Spain
关键词
Hg nanoparticles; electrode surface modification; nanocomposite graphite electrode; square-wave anodic stripping voltammetry; cyclic voltammetry; simultaneous metal detection; environmental analysis; ANODIC-STRIPPING VOLTAMMETRY; METAL-IONS; CADMIUM; GLUCOSE; SENSORS; ZINC; LEAD;
D O I
10.3390/chemosensors10040148
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring water quality has become a goal to prevent issues related to human health and environmental conditions. In this sense, the concentration of metal ions in water sources is screened, as these are considered persistent contaminants. In this work, we describe the implementation of customized graphite electrodes decorated with two types of Hg nanoparticles (Hg-NPs), optimized toward the electrochemical detection of Cd, Pb and Cu. Here, we combine Hg, a well-known property to form alloys with other metals, with the nanoscale features of Hg-NPs, resulting in improved electrochemical sensors towards these analytes with a substantial reduction in the used Hg amount. Hg-NPs were synthesized using poly(diallyldimethylammonium) chloride (PDDA) in a combined role as a reducing and stabilizing agent, and then appropriately characterized by means of Transmission Electron Microscopy (TEM) and Zeta Potential. The surface of composite electrodes with optimized graphite content was modified by the drop-casting of the prepared Hg-NPs. The obtained nanocomposite electrodes were morphologically characterized by Scanning Electron Microscopy (SEM), and electrochemically by Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS). The results show that the Hg-NP-modified electrodes present better responses towards Cd(II), Pb(II) and Cu(II) detection in comparison with the bare graphite electrode. Analytical performance of sensors was evaluated by square-wave anodic stripping voltammetry (SWASV), obtaining a linear range of 0.005-0.5 mg.L-1 for Cd2+, of 0.028-0.37 mg.L-1 for Pb2+ and of 0.057-1.1 mg.L-1 for Cu2+. Real samples were analyzed using SWASV, showing good agreement with the recovery values of inductively coupled plasma-mass spectrometry (ICP-MS) measurements.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] A Versatile Carbon Fiber Cloth-supported Au Nanodendrite Sensor for Simultaneous Determination of Cu(II), Pb(II) and Hg(II)
    Vu Hai Dang
    Pham Thi Hai Yen
    Nguyen Quynh Giao
    Pham Hong Phong
    Vu Thi Thu Ha
    Pham Khac Duy
    Hoeil, Chung
    ELECTROANALYSIS, 2018, 30 (10) : 2222 - 2227
  • [32] Array of peptide-modified electrodes for the simultaneous determination of Pb(II), Cd(II) and Zn(II)
    Serrano, Nuria
    Prieto-Simon, Beatriz
    Ceto, Xavier
    del Valle, Manel
    TALANTA, 2014, 125 : 159 - 166
  • [33] STUDIES ON THE COMPLEXES OF CU(II), HG(II) AND PB(II) WITH BENZAMIDOTHIOSEMICARBAZIDE
    ANSARI, MN
    JAIN, MC
    MALIK, WU
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 1980, 57 (10) : 1023 - 1025
  • [34] CaCO3-coated PVA/BC-based composite for the simultaneous adsorption of Cu(II), Cd(II), Pb(II) in aqueous solution
    Zhang, Yu
    Zhang, Liang
    Gao, Ruohui
    Zhong, Lvling
    Xue, Juanqin
    CARBOHYDRATE POLYMERS, 2021, 267
  • [35] Simultaneous determination of Zn(II), Cd(II) and Hg(II) in water
    Raimundo, IM
    Narayanaswamy, R
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 90 (1-3) : 189 - 197
  • [36] UiO-66 based electrochemical sensor for simultaneous detection of Cd(II) and Pb(II)
    Ding, Yanan
    Wei, Feng
    Dong, Changchang
    Li, Jiadong
    Zhang, Chang
    Han, Xiaojun
    INORGANIC CHEMISTRY COMMUNICATIONS, 2021, 131
  • [37] Selective Detection of Hg(II) Over Cd(II) and Pb(II) Ions by DNA Functionalized CNT
    Paul, Ambarish
    Bhattacharya, Baidurya
    Bhattacharyya, Tarun K.
    IEEE SENSORS JOURNAL, 2015, 15 (05) : 2774 - 2779
  • [38] Modification of carbon screen-printed electrodes by adsorption of chemically synthesized Bi nanoparticles for the voltammetric stripping detection of Zn(II), Cd(II) and Pb(II)
    Granado Rico, Ma Angeles
    Olivares-Marin, Mara
    Pinilla Gil, Eduardo
    TALANTA, 2009, 80 (02) : 631 - 635
  • [39] Simultaneous Determination of Hg(II), Cd(II), Pb(II) and Zn(II) by Anodic Stripping Voltammetry using Modified Carbon Paste Ionic Liquid Electrode
    Faridan, Ashkan
    Bahmaei, Manochehr
    Sharif, Amirabdolah Mehrdad
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2020, 12 (06): : 810 - 827
  • [40] Au nanodendrite incorporated graphite pencil lead as a sensitive and simple electrochemical sensor for simultaneous detection of Pb(II), Cu(II) and Hg(II)
    Nguyen Quynh Giao
    Vu Hai Dang
    Pham Thi Hai Yen
    Pham Hong Phong
    Vu Thi Thu Ha
    Pham Khac Duy
    Hoeil Chung
    Journal of Applied Electrochemistry, 2019, 49 : 839 - 846