Composite Electrodes Based on Carbon Materials Decorated with Hg Nanoparticles for the Simultaneous Detection of Cd(II), Pb(II) and Cu(II)

被引:9
|
作者
Fernandez, Laia L. [1 ,2 ]
Bastos-Arrieta, Julio [3 ]
Palet, Cristina [1 ]
Baeza, Mireia [2 ]
机构
[1] Univ Autonoma Barcelona, Fac Sci, Dept Chem, GTS Res Grp, Edifici C Nord, Bellaterra 08193, Spain
[2] Univ Autonoma Barcelona, Fac Sci, Dept Chem, GENOCOV Res Grp, Edifici C Nord, Bellaterra 08193, Spain
[3] Univ Barcelona, Dept Chem Engn & Analyt Chem, Grp Electroanal, Carrer Marti & Franques 1-11, Barcelona 08028, Spain
关键词
Hg nanoparticles; electrode surface modification; nanocomposite graphite electrode; square-wave anodic stripping voltammetry; cyclic voltammetry; simultaneous metal detection; environmental analysis; ANODIC-STRIPPING VOLTAMMETRY; METAL-IONS; CADMIUM; GLUCOSE; SENSORS; ZINC; LEAD;
D O I
10.3390/chemosensors10040148
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring water quality has become a goal to prevent issues related to human health and environmental conditions. In this sense, the concentration of metal ions in water sources is screened, as these are considered persistent contaminants. In this work, we describe the implementation of customized graphite electrodes decorated with two types of Hg nanoparticles (Hg-NPs), optimized toward the electrochemical detection of Cd, Pb and Cu. Here, we combine Hg, a well-known property to form alloys with other metals, with the nanoscale features of Hg-NPs, resulting in improved electrochemical sensors towards these analytes with a substantial reduction in the used Hg amount. Hg-NPs were synthesized using poly(diallyldimethylammonium) chloride (PDDA) in a combined role as a reducing and stabilizing agent, and then appropriately characterized by means of Transmission Electron Microscopy (TEM) and Zeta Potential. The surface of composite electrodes with optimized graphite content was modified by the drop-casting of the prepared Hg-NPs. The obtained nanocomposite electrodes were morphologically characterized by Scanning Electron Microscopy (SEM), and electrochemically by Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS). The results show that the Hg-NP-modified electrodes present better responses towards Cd(II), Pb(II) and Cu(II) detection in comparison with the bare graphite electrode. Analytical performance of sensors was evaluated by square-wave anodic stripping voltammetry (SWASV), obtaining a linear range of 0.005-0.5 mg.L-1 for Cd2+, of 0.028-0.37 mg.L-1 for Pb2+ and of 0.057-1.1 mg.L-1 for Cu2+. Real samples were analyzed using SWASV, showing good agreement with the recovery values of inductively coupled plasma-mass spectrometry (ICP-MS) measurements.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Simultaneous Titration of Ternary Mixtures of Pb(II), Cd(II) and Cu(II) with Potentiometric Electronic Tongue Detection
    Wilson, Deivy
    Alegret, Salvador
    del Valle, Manel
    ELECTROANALYSIS, 2015, 27 (02) : 336 - 342
  • [22] Stripping analysis of Pb(II), Cd(II), Hg(II) and Cu(II) based on irradiated attapulgite/Ionic liquid composites
    Xiong, Shiquan
    Xu, Juncui
    Xie, Fazhi
    Hu, Xianhai
    Gong, Guohong
    Wu, Zhengyan
    Yao, Liming
    CHEMICAL ENGINEERING JOURNAL, 2017, 316 : 383 - 392
  • [23] Three-dimensional graphene/amino-functionalized metal-organic framework for simultaneous electrochemical detection of Cd(II), Pb(II), Cu(II), and Hg(II)
    Huo, Danqun
    Zhang, Ya
    Li, Ning
    Ma, Wenhao
    Liu, Huan
    Xu, Guoren
    Li, Zhihua
    Yang, Mei
    Hou, Changjun
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (04) : 1575 - 1586
  • [24] Simultaneous electrochemical detection of Cd(II), Pb(II), As(III) and Hg(II) ions using ruthenium(II)-textured graphene oxide nanocomposite
    Gumpu, Manju Bhargavi
    Veerapandian, Murugan
    Krishnan, Uma Maheswari
    Rayappan, John Bosco Balaguru
    TALANTA, 2017, 162 : 574 - 582
  • [25] Adsorption on toxic metal Pb(II), Cd(II), Hg(II) and Cu(II) ions on agricultural byproducts
    Meshram, YK
    ASIAN JOURNAL OF CHEMISTRY, 2004, 16 (02) : 1104 - 1108
  • [26] Development of an immunochromatographic strip and its application in the simultaneous determination of Hg(II), Cd(II) and Pb(II)
    Zhou, Yu
    Li, Yan-Song
    Meng, Xing-Yu
    Zhang, Yuan-Yuan
    Yang, Li
    Zhang, Jun-Hui
    Wang, Xin-Rui
    Lu, Shi-Ying
    Ren, Hong-Lin
    Liu, Zeng-Shan
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 183 : 303 - 309
  • [27] Simultaneous Adsorption of Pb(Ii)-Cd(Ii), Pb(Ii)-Phenol, and Cd(Ii)-Phenol by Activated Carbon Cloth in Aqueous Solution
    Arcibar-Orozco, Javier A.
    Rangel-Mendez, Jose R.
    Diaz-Flores, Paola E.
    WATER AIR AND SOIL POLLUTION, 2015, 226 (01):
  • [28] Simultaneous Adsorption of Pb(Ii)-Cd(Ii), Pb(Ii)-Phenol, and Cd(Ii)-Phenol by Activated Carbon Cloth in Aqueous Solution
    Javier A. Arcibar-Orozco
    Jose R. Rangel-Mendez
    Paola E. Diaz-Flores
    Water, Air, & Soil Pollution, 2015, 226
  • [29] Carbon paste electrode modified with fern leave-like MIL-47(as) for electrochemical simultaneous detection of Pb(II), Cu(II) and Hg(II)
    Niu, Baitong
    Yao, Biying
    Zhu, Meihua
    Guo, Hongxu
    Ying, Shaoming
    Chen, Zhangxu
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 886
  • [30] Carbon paste electrode modified with fern leave-like MIL-47(as) for electrochemical simultaneous detection of Pb(II), Cu(II) and Hg(II)
    Niu, Baitong
    Yao, Biying
    Zhu, Meihua
    Guo, Hongxu
    Ying, Shaoming
    Chen, Zhangxu
    Journal of Electroanalytical Chemistry, 2021, 886