Secondary cancer risk after whole-breast radiation therapy: field-in-field versus intensity modulated radiation therapy versus volumetric modulated arc therapy

被引:22
|
作者
Haciislamoglu, Emel [1 ]
Cinar, Yunus [2 ]
Gurcan, Fatih [3 ]
Canyilmaz, Emine [1 ]
Gungor, Gorkem [4 ]
Yoney, Adnan [4 ]
机构
[1] Karadeniz Tech Univ, Fac Med, Dept Radiat Oncol, Trabzon, Turkey
[2] Recep Tayyip Erdogan Univ, Fac Med, Dept Radiat Oncol, Rize, Turkey
[3] Karadeniz Tech Univ, Fac Engn, Dept Comp Engn, Trabzon, Turkey
[4] Acibadem Univ, Dept Radiat Oncol, Istanbul, Turkey
来源
BRITISH JOURNAL OF RADIOLOGY | 2019年 / 92卷 / 1102期
关键词
EXTERNAL-BEAM RADIOTHERAPY; CONTRALATERAL BREAST; CONVENTIONAL WEDGE; IMRT; 3D-CRT; IRRADIATION; STANDARD; IMPACT; VMAT; BOMB;
D O I
10.1259/bjr.20190317
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: In this study, we used the concept of organ-equivalent dose (OED) to evaluate the excess absolute risk (EAR) for secondary cancer in various organs after radiation treatment for breast cancer. Methods: Using CT data set of 12 patients, we generated three different whole-breast radiation treatment plans using 50 Gy in 2Gy fractions: three-dimensional conformal radiotherapy with a field-in-field (FinF) technique, intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). The OEDs were calculated from differential dose-volume histograms on the basis of the "linear-exponential," "plateau," and ''full mechanistic" dose-response models. Secondary cancer risks of the contralateral breast (CB), contralateral lung (CL), and ipsilateral lung (IL) were estimated and compared. Results: The lowest EARs for the CB, CL, and IL were achieved with FinF, which reduced the EARs by 77%, 88%. and 56% relative to those with IMRT, and by 77%, 84%, and 58% relative to those with VMAT, respectively. The secondary cancer risk for FinF was significantly lower than those of IMRT and VMAT. OED-based secondary cancer risks for CB and IL were similar when IMRT and VMAT were used, but the risk for CL was statistically lower when VMAT was used. Conclusion: The overall estimation of EAR indicated that the radiation-induced cancer risk of breast radiation therapy was lower with FinF than with IMRT and VMAT. Therefore, when secondary cancer risk is a major concern, FinF is considered to be the preferred treatment option in irradiation of whole-breast. Advances in knowledge: Secondary malignancy estimation after breast radiotherapy is becoming an important subject for comparative treatment planning.When secondary cancer risk a major concern, FinF technique is considered the preferred treatment option in whole breast patients.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Comparison of Intensity-Modulated Radiation Therapy, Intensity-Modulated Arc Therapy and Arc-Modulated Radiation Therapy
    Tang, G.
    Earl, M.
    Luan, S.
    Wang, C.
    Naqvi, S.
    Yu, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [22] Predictive factors for acute radiation pneumonitis in postoperative intensity modulated radiation therapy and volumetric modulated arc therapy of esophageal cancer
    Zhao, Yaqin
    Chen, Lu
    Zhang, Shu
    Wu, Qiang
    Jiang, Xiaoqin
    Zhu, Hong
    Wang, Jin
    Li, Zhiping
    Xu, Yong
    Zhang, Ying Jie
    Bai, Sen
    Xu, Feng
    THORACIC CANCER, 2015, 6 (01) : 49 - 57
  • [23] Dosimetric comparison of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy for free-breathing whole-breast irradiation: A planning study
    Czeremszynska, Beata
    Socha, Joanna
    Rygielska, Anna
    Walewska, Agnieszka
    Gabor, Marta
    Pruska-Pich, Dorota
    Osowiecka, Karolina
    Kepka, Lucyna
    INDIAN JOURNAL OF CANCER, 2023, 60 (02) : 258 - 265
  • [24] Impact of machines on plan quality: volumetric modulated arc therapy and intensity modulated radiation therapy
    Clemente, S.
    Cozzolino, M.
    Oliviero, C.
    Fiorentino, A.
    Chiumento, C.
    Fusco, V.
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2014, 16 (02): : 141 - 146
  • [25] Impact of machines on plan quality: volumetric modulated arc therapy and intensity modulated radiation therapy
    S. Clemente
    M. Cozzolino
    C. Oliviero
    A. Fiorentino
    C. Chiumento
    V. Fusco
    Clinical and Translational Oncology, 2014, 16 : 141 - 146
  • [26] Dosimetric Analysis and Comparison of Volumetric Modulated Arc Therapy vs Intensity Modulated Radiation Therapy for Anal Cancer
    Hibbitts, K.
    Chiang, B.
    Ortega, H.
    Herman, T.
    Ahmad, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E623 - E623
  • [27] Comparison of Dosimetric Analysis of Volumetric Modulated Arc Therapy Vs Intensity Modulated Radiation Therapy for Anal Cancer
    Chiang, B.
    Hibbitts, K.
    Ortega, H.
    Herman, T.
    Ahmad, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E305 - E305
  • [28] Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer
    Lin, Jia-Fu
    Yeh, Dah-Cherng
    Yeh, Hui-Ling
    Chang, Chen-Fa
    Lin, Jin-Ching
    MEDICAL DOSIMETRY, 2015, 40 (03) : 262 - 267
  • [29] Dosimetric comparison of helical tomotherapy, volumetric-modulated arc therapy, intensity-modulated radiotherapy, and field-in-field technique for synchronous bilateral breast cancer
    Cheng, Hao-Wen
    Chang, Chih-Chieh
    Shiau, An-Cheng
    Wang, Ming-Hua
    Tsai, Jo-Ting
    MEDICAL DOSIMETRY, 2020, 45 (03) : 271 - 277
  • [30] Feasibility of Extended Field Radiation using Volumetric Modulated Arc Therapy in Prostate Cancer
    Sharma, Deepak
    Periasamy, Kannan
    Goyal, Shikha
    Kumar, Santosh
    Mavuduru, Ravi Mohan S.
    Kumar, Rajender
    Singh, Ranjit
    RADIOTHERAPY AND ONCOLOGY, 2024, 197 : S284 - S286