Fat quantification with IDEAL gradient echo imaging:: Correction of bias from T1 and noise

被引:402
|
作者
Liu, Chia-Ying
McKenzie, Charles A.
Yu, Huanzhou
Brittain, Jean H.
Reeder, Scott B.
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53706 USA
[4] Univ Wisconsin, Dept Med, Madison, WI 53706 USA
[5] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[6] Harvard Univ, Sch Med, Boston, MA USA
[7] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[8] GE Healthcare, Global Appl Sci Lab, Madison, WI USA
关键词
fat quantification; IDEAL; chemical shift imaging; hepatic steatosis; magnetic resonance imaging;
D O I
10.1002/mrm.21301
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantification of hepatic steatosis is a significant unmet need for the diagnosis and treatment of patients with nonalcoholic fatty liver disease (NAFLD). MRI is capable of separating water and fat signals in order to quantify fatty infiltration of the liver (hepatic steatosis). Unfortunately, fat signal has confounding T-1 effects and the nonzero mean noise in low signal-to-noise ratio (SNR) magnitude images can lead to incorrect estimation of the true lipid percentage. In this study, the effects of bias from T-1 effects and image noise were investigated. An oil/water phantom with volume fat-fractions ranging linearly from 0% to 100% was designed and validated using a spoiled gradient echo (SPGR) sequence in combination with a chemical-shift based fat-water separation method known as iterative decomposition of water and fat with echo asymmetry and least squares estimation (IDEAL). We demonstrated two approaches to reduce the effects of T-1: small flip angle (flip angle) and dual flip angle methods. Both methods were shown to effectively minimize deviation of the measured fat-fraction from its true value. We also demonstrated two methods to reduce noise bias: magnitude discrimination and phase-constrained reconstruction. Both methods were shown to reduce this noise bias effectively from 15% to less than 1%.
引用
收藏
页码:354 / 364
页数:11
相关论文
共 50 条
  • [21] Fat-suppressed 3D-T1-weighted-echo planar imaging: comparison with fat-suppressed 3D-T1-weighted-gradient echo in imaging the cartilage of the knee
    Karantanas, AH
    Zibis, AH
    Kitsoulis, P
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (03) : 159 - 165
  • [22] Cardiovascular magnetic resonance assessment of human myocarditis: IR gradient echo compared with T1 turbo spin-echo imaging protocols
    Hager, S
    Mahrholdt, H
    Mangin, M
    Wagner, A
    Sechtem, U
    CIRCULATION, 2004, 110 (17) : 678 - 678
  • [23] Comparison of High Resolution Gradient Echo, XBONE T1, XBONE T2, Spin Echo T1 and 3D SST1 magnetic resonance imaging sequences for imagining the canine elbow
    Zhalniarovich, Y.
    Adamiak, Z.
    Glodek, J.
    Przyborowska, P.
    Holak, P.
    POLISH JOURNAL OF VETERINARY SCIENCES, 2014, 17 (04): : 587 - 591
  • [24] Rapid T1 mapping using multislice echo planar imaging
    Clare, S
    Jezzard, P
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) : 630 - 634
  • [25] Accurate multislice gradient echo T1 measurement in the presence of non-ideal RF pulse shape and RF field nonuniformity
    Parker, GJM
    Barker, GJ
    Tofts, PS
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) : 838 - 845
  • [26] Magnetic Resonance Fingerprinting Using Echo-Planar Imaging: Joint Quantification of T1 and T2* Relaxation Times
    Rieger, Benedikt
    Zimmer, Fabian
    Zapp, Jascha
    Weingaertner, Sebastian
    Schad, Lothar R.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1724 - 1733
  • [27] MS Lesions Are Better Detected with 3D T1 Gradient-Echo Than with 2D T1 Spin-Echo Gadolinium-Enhanced Imaging at 3T
    Crombe, A.
    Saranathan, M.
    Ruet, A.
    Durieux, M.
    de Roquefeuil, E.
    Ouallet, J. C.
    Brochet, B.
    Dousset, V.
    Tourdias, T.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (03) : 501 - 507
  • [28] Ovarian Masses: MR Imaging with T1-weighted 3-dimensional Gradient-echo IDEAL Water-fat Separation Sequence at 3T
    Hori, Masatoshi
    Kim, Tonsok
    Onishi, Hiromitsu
    Nakamoto, Atsushi
    Tsuboyama, Takahiro
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2012, 11 (02) : 117 - 127
  • [29] MR fingerprinting for water T1 and fat fraction quantification in fat infiltrated skeletal muscles
    Marty, Benjamin
    Carlier, Pierre G.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (02) : 621 - 634
  • [30] Quantification of liver iron concentration with magnetic resonance imaging by combining T1-, T2-weighted spin echo sequences and a gradient echo sequence
    Kreeftenberg, HG
    Mooyaart, EL
    Huizenga, JR
    Sluiter, WJ
    Kreeftenberg, HG
    NETHERLANDS JOURNAL OF MEDICINE, 2000, 56 (04): : 133 - 137