Determination of HbA1c in the presence of haemoglobin variants:: Comparison of three HPLC techniques

被引:0
|
作者
Carta, M [1 ]
Dall'Olio, G [1 ]
Soffiati, G [1 ]
机构
[1] Osped S Bortolo, Chim Clin & Ematol Lab, I-36100 Vicenza, Italy
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The presence of Hb variants may cause analytical interference in HbA(1c), values measured with the HPLC techniques currently used in Italian laboratories. In this study performance of a new HPLC system, (HA-8140, Menarini) was compared with two other traditional HPLC systems (HA-8121, Menarini and Diamat, Bio-Rad). The HA-8140 system detects the Kb variant possibly present in an independent peak. The integration area of such a peak is not computed in the calculation of the percentage value of HbA(1c). In this manner the underestimation of values obtained with traditional HPLC systems is avoided.
引用
收藏
页码:923 / 925
页数:3
相关论文
共 50 条
  • [41] Glycated Haemoglobin (HbA1C) in Cardiac Surgery: A Narrative Review
    Luthra, Suvitesh
    Viola, Laura
    Navaratnarajah, Manoraj
    Thirukumaran, David
    Velissaris, Theodore
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (01)
  • [42] HBA1C DETERMINATION IN CAPILLARY BLOOD
    WOODTLI, T
    RUCH, W
    FLUCKIGER, R
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1987, 117 (02) : 43 - 45
  • [43] INTERFERENCE OF CARBAMYLATED HEMOGLOBIN IN GLYCOSYLATED HAEMOGLOBIN (HbA1c) ANALYSIS
    Subramaniam, S.
    Shyama, S.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A46 - A47
  • [44] Interference of common haemoglobin variants with the Tosoh G7 standard mode HbA1c method
    Piehler, Armin P.
    Grimholt, Runa M.
    Bjerner, Johan
    Buchmann, Marie S.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2015, 75 (05): : 362 - 366
  • [45] Evaluation and comparison of two methods for quantification of HbA1c with the reference HPLC method
    Kurti, L.
    Kelmendi, A.
    Osmani, I.
    Kurti, G. Mucaj
    CLINICA CHIMICA ACTA, 2024, 558
  • [46] Falsely high glycated haemoglobin [HbA1C] because of haemoglobin OSU-Christiansborg
    Kapoor, D
    Ng, JP
    Jones, TH
    CLINICAL AND LABORATORY HAEMATOLOGY, 2005, 27 (05): : 334 - 335
  • [47] Labile glycated haemoglobin and carbamylated haemoglobin are still critical points for HbA1C measurement
    Desmons, Aurore
    Jaisson, Stephane
    Leroy, Nathalie
    Gillery, Philippe
    Guillard, Emmanuelle
    BIOCHEMIA MEDICA, 2017, 27 (02) : 378 - 386
  • [48] Determination of HbA1c concentrations in patients with acute myocardial infarction:: Comparison of the DCA 2000 device with the HPLC method
    Hadjadj, S
    Duengler, F
    Barriere, M
    Mauco, G
    Coisne, D
    Warnier, F
    Sosner, P
    Torremocha, F
    Herpin, D
    Marechaud, R
    DIABETES & METABOLISM, 2005, 31 (03) : 290 - 294
  • [49] Interpreting HbA1c in Presence of Deficiency Anemias
    Seema Bhargava
    Khageshwar Mahato
    Anjali Manocha
    Mamta Kankra
    Parul Singla
    Anisha Sharma
    Ashok Ahirwar
    Vinod Gupta
    Salamma Jose
    Indian Journal of Clinical Biochemistry, 2021, 36 : 360 - 364
  • [50] Glycated hemoglobin (HbA1c) determination: A comparison of assay methods.
    Rebolledo, OR
    Dato, SMA
    Brizzio, AM
    Gagliardino, JJ
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2001, 35 (03): : 355 - 361