CdTe and CdZnTe detectors in nuclear medicine

被引:61
|
作者
Scheiber, C [1 ]
机构
[1] Fac Med Strasbourg, Inst Phys Biol, F-67085 Strasbourg, France
关键词
semiconductor detectors; CdTe; CZT; nuclear camera; imaging;
D O I
10.1016/S0168-9002(00)00282-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Nuclear medicine diagnostic applications are growing in search for more disease specific or more physiologically relevant imaging. The data are obtained non-invasively from large field gamma cameras or from miniaturised probes. As far as single photon emitters are concerned, often labelled with Tc-99m (140 keV, gamma), nuclear instrumentation deals with poor counting statistics due to the method of spatial localisation and low contrast to noise due to scatter in the body. Since the 1960s attempts have been made to replace the NaI scintillator by semiconductor detectors with better spectrometric characteristics to improve contrast and quantitative measurements. They allow direct conversion of energy and thus more compact sensors. Room-temperature semiconductor detectors such as cadmium tellure and cadmium zinc tellure have favourable physical characteristics for medical applications which have been investigated in the 1980s. During one decade, they have been used in miniaturised probes such as for inter-operative surgery guidance which is today in a fast growing phase. This material suffers from charge transport problems which has slowed down imaging applications. Owing to a considerable research work on material, contacts and dedicated electronics small field of view compact pixellated gamma cameras have been prototyped and one already marketed. Although extended clinical evaluation has to be conducted and long-term reliability assesed, the available data already confirm the expected gain in image contrast. Medical interest for dedicated imaging systems is greater than it was in the 1980s when the first mobile gamma cameras were marketed. The future of CdTe or CdZnTe-based imager for routine use now relies at first on industrial costs. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:513 / 524
页数:12
相关论文
共 50 条
  • [41] Comparison of the radiation damage induced by thermal neutrons in CdTe and CdZnTe detectors
    Chirco, P
    Morigi, MP
    Zanarini, M
    Cavallini, A
    Fraboni, B
    Auricchio, N
    Caroli, E
    Dusi, W
    Fougeres, P
    Hage-Ali, M
    Siffert, P
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 : 424 - 432
  • [42] Technological aspects of development of pixel and strip detectors based on CdTe and CdZnTe
    Gostilo, V
    Ivanov, V
    Kostenko, S
    Lisjutin, I
    Loupilov, A
    Neneonen, S
    Sipila, H
    Valpas, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 460 (01): : 27 - 34
  • [43] CdZnTe arrays for nuclear medicine imaging
    Barber, HB
    HARD X-RAY/GAMMA-RAY AND NEUTRON OPTICS, SENSORS, AND APPLICATIONS, 1996, 2859 : 26 - 28
  • [44] Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications
    Verger, L
    Boitel, M
    Gentet, MC
    Hamelin, R
    Mestais, C
    Mongellaz, F
    Rustique, J
    Sanchez, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 297 - 309
  • [45] Advances in high-resolution CdTe and large volume CdZnTe detectors
    Arlt, R
    Ivanov, V
    Khusainov, A
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS, OPTICS, AND APPLICATIONS, 1997, 3115 : 76 - 89
  • [46] Study of CdTe and CdZnTe detectors for X-ray computed tomography
    Ricq, S
    Glasser, F
    Garcin, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 534 - 543
  • [47] INFLUENCE OF RADIATION-INDUCED DEFECTS ON CdTe AND CdZnTe DETECTORS PROPERTIES
    Kondrik, A. I.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2015, (02): : 18 - 24
  • [48] High performance p-i-n CdTe and CdZnTe detectors
    Khusainov, AK
    Dudin, AL
    Ilves, AG
    Morozov, VF
    Pustovoit, AK
    Arlt, RD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (01): : 58 - 65
  • [49] Comparison of CdTe and CdZnTe detectors for field determination of uranium isotopic enrichments
    Hofstetter, KJ
    Beals, DM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 263 (01) : 171 - 176
  • [50] Application of Detectors Based on the Wide-Gap Semiconductors CdTe, CdZnTe, and GaAs for Nuclear Power Plant Safety Monitoring
    V. M. Azhazha
    V. E. Kutnii
    A. V. Rybka
    I. N. Shlyakhov
    D. V. Kutnii
    A. A. Zakharchenko
    Atomic Energy, 2002, 92 : 508 - 513