Flow injection analysis electrospray ionization mass spectrometry for high-throughput screening of a gene library for amidase activity

被引:5
|
作者
Henderickx, Huub J. W. [1 ]
Raemakers-Franken, Petronella C. [2 ]
van der Wal, Sjoerd [1 ]
de Koster, Chris G. [3 ]
Duchateau, Alexander L. L. [2 ]
Sonke, Theo [2 ]
机构
[1] DSM Resolve, NL-6160 MD Geleen, Netherlands
[2] DSM Pharmaceut Prod, Innovat Synth & Catalysis, NL-6160 MD Geleen, Netherlands
[3] Univ Amsterdam, Swammerdam Inst Life Sci, NL-1018 WV Amsterdam, Netherlands
关键词
FIA-ESI-MS; Selected ion monitoring; Biocatalyst screening; Amidase activity; Mycobacterium neoaurum; ALPHA-AMINO-ACIDS;
D O I
10.1016/j.ab.2009.07.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In high-throughput screening of gene and mutant libraries, high analysis speeds and short method development times are important factors. Mass spectrometry (MS) is considered to be a generic analytical technique with a relatively short development time. Furthermore, when applying flow injection analysis (FIA) for sample introduction, the requirements for high throughput are met. In this work, the use of a single quadrupole electrospray MS instrument for assaying amidase activity in a gene library is demonstrated. The desired selectivity for measuring the amino acid, the reaction product of the amidase reaction, in the presence of high concentrations of the corresponding amino acid amide substrate was obtained by selective ionization of the amino acid in negative ion mode electrospray. The only sample preparation required was a 200-fold dilution of the reaction mixture. For obtaining quantitative results, a complementary calibration procedure was set up to correct for the change in ionization suppression as a function of conversion. This approach was used to screen a Mycobacterium neoaurum gene library consisting of 11,520 clones with alpha-methylleucine amide as substrate within 24 h. Conversion was measured on the [M-H](-) species of the corresponding alpha-methylleucine (m/z 144). Five positive clones were detected with a conversion ranging from 0.2% to 3.4%. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 50 条
  • [31] High-throughput analysis of peptides and proteins by laserspray ionization mass spectrometry
    Richards, Alicia L.
    Marshall, Darrell D.
    Inutan, Ellen D.
    McEwen, Charles N.
    Trimpin, Sarah
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (01) : 247 - 250
  • [32] Rapid evaporative ionization mass spectrometry for high-throughput screening in food analysis: The case of boar taint
    Verplanken, Kaat
    Stead, Sara
    Jandova, Renata
    Van Poucke, Christof
    Claereboudt, Jan
    Vanden Bussche, Julie
    De Saeger, Sarah
    Takats, Zoltan
    Wauters, Jella
    Vanhaecke, Lynn
    TALANTA, 2017, 169 : 30 - 36
  • [33] The automatic visualisation of carry-over in high-throughput flow injection analysis mass spectrometry
    Richmond, R
    Görlach, E
    ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) : 175 - 183
  • [34] High-throughput chemical residue analysis by fast extraction and dilution flow injection mass spectrometry
    Nanita, Sergio C.
    ANALYST, 2011, 136 (02) : 285 - 287
  • [35] Field-induced wooden-tip electrospray ionization mass spectrometry for high-throughput analysis of herbal medicines
    Yang, Yunyun
    Deng, Jiewei
    Yao, Zhong-Ping
    ANALYTICA CHIMICA ACTA, 2015, 887 : 127 - 137
  • [36] Late-Stage Functionalization and Characterization of Drugs by High-Throughput Desorption Electrospray Ionization Mass Spectrometry
    Huang, Kai-Hung
    Ghosh, Jyotirmoy
    Xu, Shiqing
    Cooks, R. Graham
    CHEMPLUSCHEM, 2022, 87 (01):
  • [37] Rapid analytical characterization of high-throughput chemistry screens utilizing desorption electrospray ionization mass spectrometry
    Sawicki, James W.
    Bogdan, Andrew R.
    Searle, Philip A.
    Talaty, Nari
    Djuric, Stevan W.
    REACTION CHEMISTRY & ENGINEERING, 2019, 4 (09): : 1589 - 1594
  • [38] Imaging mass spectrometry and high-throughput screening.
    Winograd, N
    Xu, JY
    Braun, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 218 : U170 - U170
  • [39] Applications of ambient mass spectrometry in high-throughput screening
    Li, Li-Ping
    Feng, Bao-Sheng
    Yang, Jian-Wang
    Chang, Cui-Lan
    Bai, Yu
    Liu, Hu-Wei
    ANALYST, 2013, 138 (11) : 3097 - 3103
  • [40] High-Throughput Pesticide Residue Quantitative Analysis Achieved by Tandem Mass Spectrometry with Automated Flow Injection
    Nanita, Sergio C.
    Pentz, Anne M.
    Bramble, Frederick Q.
    ANALYTICAL CHEMISTRY, 2009, 81 (08) : 3134 - 3142