Flow injection analysis electrospray ionization mass spectrometry for high-throughput screening of a gene library for amidase activity

被引:5
|
作者
Henderickx, Huub J. W. [1 ]
Raemakers-Franken, Petronella C. [2 ]
van der Wal, Sjoerd [1 ]
de Koster, Chris G. [3 ]
Duchateau, Alexander L. L. [2 ]
Sonke, Theo [2 ]
机构
[1] DSM Resolve, NL-6160 MD Geleen, Netherlands
[2] DSM Pharmaceut Prod, Innovat Synth & Catalysis, NL-6160 MD Geleen, Netherlands
[3] Univ Amsterdam, Swammerdam Inst Life Sci, NL-1018 WV Amsterdam, Netherlands
关键词
FIA-ESI-MS; Selected ion monitoring; Biocatalyst screening; Amidase activity; Mycobacterium neoaurum; ALPHA-AMINO-ACIDS;
D O I
10.1016/j.ab.2009.07.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In high-throughput screening of gene and mutant libraries, high analysis speeds and short method development times are important factors. Mass spectrometry (MS) is considered to be a generic analytical technique with a relatively short development time. Furthermore, when applying flow injection analysis (FIA) for sample introduction, the requirements for high throughput are met. In this work, the use of a single quadrupole electrospray MS instrument for assaying amidase activity in a gene library is demonstrated. The desired selectivity for measuring the amino acid, the reaction product of the amidase reaction, in the presence of high concentrations of the corresponding amino acid amide substrate was obtained by selective ionization of the amino acid in negative ion mode electrospray. The only sample preparation required was a 200-fold dilution of the reaction mixture. For obtaining quantitative results, a complementary calibration procedure was set up to correct for the change in ionization suppression as a function of conversion. This approach was used to screen a Mycobacterium neoaurum gene library consisting of 11,520 clones with alpha-methylleucine amide as substrate within 24 h. Conversion was measured on the [M-H](-) species of the corresponding alpha-methylleucine (m/z 144). Five positive clones were detected with a conversion ranging from 0.2% to 3.4%. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 50 条
  • [21] High-throughput screening of toxic substances by extractive electrospray ionization mass spectrometry and their identification via databank construction
    Wang, Shuanglong
    Li, Faliang
    Liu, YongZi
    Zhao, Huian
    Chen, Huanwen
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (18) : 4049 - 4054
  • [22] Rapid Exploration of Chemical Space by High-Throughput Desorption Electrospray Ionization Mass Spectrometry
    Huang, Kai-Hung
    Morato, Nicolas M.
    Feng, Yunfei
    Toney, Alexis
    Cooks, R. Graham
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2024, 146 (48) : 33112 - 33120
  • [23] Novel Interface for High-Throughput Analysis of Biotherapeutics by Electrospray Mass Spectrometry
    Park, Hae-Min
    Winton, Valerie J.
    Drader, Jared J.
    Wheeler, Sheri Manalili
    Lazar, Greg A.
    Kelleher, Neil L.
    Liu, Yichin
    Tran, John C.
    Compton, Philip D.
    ANALYTICAL CHEMISTRY, 2020, 92 (02) : 2186 - 2193
  • [24] Normalization techniques for high-throughput screening by infrared matrix-assisted laser desorption electrospray ionization mass spectrometry
    Knizner, Kevan T.
    Bagley, Michael C.
    Pu, Fan
    Elsen, Nathaniel L.
    Williams, Jon D.
    Muddiman, David C.
    JOURNAL OF MASS SPECTROMETRY, 2022, 57 (06):
  • [25] Flow Injection-Electrospray Ionization Mass Spectrometry Based High-Throughput Inhibition Screening of Herbal Extracts Toward Major Human Cytochrome P450s
    Guo Bin
    Duan Jun-Min
    Wang Mei-Ling
    Wang Xiao-Ying
    Chen Bo
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (12) : 1692 - 1697
  • [26] High throughput analysis of MMA by electrospray ionization tandem mass spectrometry.
    Kushnir, MM
    Komaromy-Hiller, G
    Shushan, B
    Urry, FM
    Roberts, WL
    CLINICAL CHEMISTRY, 2001, 47 (06) : A64 - A64
  • [27] High-resolution acoustic ejection mass spectrometry for high-throughput library screening
    Hoxie, Nate
    Calabrese, David R.
    Itkin, Zina
    Gomba, Glenn
    Shen, Min
    Verma, Meghav
    Janiszewski, John S.
    Shrimp, Jonathan H.
    Wilson, Kelli M.
    Michael, Sam
    Hall, Matthew D.
    Burton, Lyle
    Covey, Tom
    Liu, Chang
    SLAS TECHNOLOGY, 2024, 29 (06):
  • [28] Analytical Evaluation of the Ideal Strategy for High-Throughput Flow Injection Analysis by Tandem Mass Spectrometry in Routine Newborn Screening
    Cicalini, Ilaria
    Valentinuzzi, Silvia
    Pieragostino, Damiana
    Consalvo, Ada
    Zucchelli, Mirco
    Donzelli, Simone
    Ambrogi, Davide
    Brown, Heather A.
    Calton, Lisa J.
    Stuppia, Liborio
    De Laurenzi, Vincenzo
    Del Boccio, Piero
    Rossi, Claudia
    METABOLITES, 2021, 11 (08)
  • [29] High-throughput detection of drugs binding to proteins using desorption electrospray ionization mass spectrometry
    Yao, Chenxi
    Na, Na
    Huang, Lingyun
    He, Dacheng
    Ouyang, Jin
    ANALYTICA CHIMICA ACTA, 2013, 794 : 60 - 66
  • [30] Inter-platform assessment of performance of high-throughput desorption electrospray ionization mass spectrometry
    Morato, Nicolas M.
    Cooks, R. Graham
    TALANTA OPEN, 2021, 4