Flow injection analysis electrospray ionization mass spectrometry for high-throughput screening of a gene library for amidase activity

被引:5
|
作者
Henderickx, Huub J. W. [1 ]
Raemakers-Franken, Petronella C. [2 ]
van der Wal, Sjoerd [1 ]
de Koster, Chris G. [3 ]
Duchateau, Alexander L. L. [2 ]
Sonke, Theo [2 ]
机构
[1] DSM Resolve, NL-6160 MD Geleen, Netherlands
[2] DSM Pharmaceut Prod, Innovat Synth & Catalysis, NL-6160 MD Geleen, Netherlands
[3] Univ Amsterdam, Swammerdam Inst Life Sci, NL-1018 WV Amsterdam, Netherlands
关键词
FIA-ESI-MS; Selected ion monitoring; Biocatalyst screening; Amidase activity; Mycobacterium neoaurum; ALPHA-AMINO-ACIDS;
D O I
10.1016/j.ab.2009.07.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In high-throughput screening of gene and mutant libraries, high analysis speeds and short method development times are important factors. Mass spectrometry (MS) is considered to be a generic analytical technique with a relatively short development time. Furthermore, when applying flow injection analysis (FIA) for sample introduction, the requirements for high throughput are met. In this work, the use of a single quadrupole electrospray MS instrument for assaying amidase activity in a gene library is demonstrated. The desired selectivity for measuring the amino acid, the reaction product of the amidase reaction, in the presence of high concentrations of the corresponding amino acid amide substrate was obtained by selective ionization of the amino acid in negative ion mode electrospray. The only sample preparation required was a 200-fold dilution of the reaction mixture. For obtaining quantitative results, a complementary calibration procedure was set up to correct for the change in ionization suppression as a function of conversion. This approach was used to screen a Mycobacterium neoaurum gene library consisting of 11,520 clones with alpha-methylleucine amide as substrate within 24 h. Conversion was measured on the [M-H](-) species of the corresponding alpha-methylleucine (m/z 144). Five positive clones were detected with a conversion ranging from 0.2% to 3.4%. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 50 条
  • [1] Electrospray ionization tandem mass spectrometry in high-throughput screening of homogeneous catalysts
    Chen, P
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2003, 42 (25) : 2832 - 2847
  • [2] High-throughput screening of catalysts by electrospray ionization tandem mass spectrometry.
    Chen, P
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U776 - U777
  • [3] High-Throughput Quantitative Analysis by Desorption Electrospray Ionization Mass Spectrometry
    Manicke, Nicholas E.
    Kistler, Thomas
    Ifa, Demian R.
    Cooks, R. Graham
    Ouyang, Zheng
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (02) : 321 - 325
  • [4] High-throughput screening of homogeneous catalyst by electrospray ionization tandem mass spectrometry.
    Chen, P
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 227 : U548 - U548
  • [5] Flow-injection electrospray ionization mass spectrometry of crude cell extracts for high-throughput bacterial identification
    Vaidyanathan, S
    Kell, DB
    Goodacre, R
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (02) : 118 - 128
  • [6] High-Throughput Screening of Reductive Amination Reactions Using Desorption Electrospray Ionization Mass Spectrometry
    Logsdon, David L.
    Li, Yangjie
    Sobreira, Tiago Jose Paschoal
    Ferreira, Christina R.
    Thompson, David H.
    Cooks, R. Graham
    ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2020, 24 (09) : 1647 - 1657
  • [7] Rotating multitip micropillar array electrospray ionization-mass spectrometry for rapid analysis and high-throughput screening
    Nissila, Teemu
    Backman, Nina
    Kolmonen, Marjo
    Leinonen, Antti
    Kiriazis, Alexandros
    Yli-Kauhaluoma, Jari
    Sainiemi, Lauri
    Kostiainen, Risto
    Franssila, Sami
    Ketola, Raimo A.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2012, 310 : 65 - 71
  • [8] High-throughput quantification of lysophosphatidylcholine by electrospray ionization tandem mass spectrometry
    Liebisch, G
    Drobnik, W
    Lieser, B
    Schmitz, G
    CLINICAL CHEMISTRY, 2002, 48 (12) : 2217 - 2224
  • [9] Multiple sprayer system for high-throughput electrospray ionization mass spectrometry
    Schneider, BB
    Douglas, DJ
    Chen, DDY
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (20) : 1982 - 1990
  • [10] Versatile platform employing desorption electrospray ionization mass spectrometry for high-throughput analysis
    Ma, Xiaoxiao
    Zhao, Mengxia
    Lin, Ziqing
    Zhang, Sichun
    Yang, Chengdui
    Zhang, Xinrong
    ANALYTICAL CHEMISTRY, 2008, 80 (15) : 6131 - 6136