Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications

被引:134
|
作者
Cavalcanti, MGP
Rocha, SS
Vannier, MW
机构
[1] Univ Sao Paulo, Coll Dent, Dept Radiol, BR-05508900 Sao Paulo, Brazil
[2] Univ Iowa, Coll Med, Dept Radiol, Iowa City, IA 52242 USA
[3] Univ Sao Paulo, Coll Dent, Depr Forens Odontol, Sao Paulo, Brazil
关键词
tomography; X-ray computed; head; computer-assisted; image processing;
D O I
10.1259/dmfr/13603271
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study was designed to determine the precision and accuracy of anthropometric measurements using three-dimensional computed tomography (3D-CT) volume rendering by computer systems for craniofacial clinical applications, and to compare the craniometric landmarks using bone and soft tissue protocols. Methods: The study population consisted of 13 cadaver heads that were examined with spiral CT. The archived CT data were transferred to a workstation, and 3D-CT volume rendered images were generated using computer graphics tools. Linear measurements (n = 10), based upon conventional craniometric anatomical landmarks (n = 08), were identified in 2D-CT and in 3D-CT images by two radiologists twice each independently, and then performed by 3D-CT imaging using a computer graphics systems using bone and soft tissue protocols. In total, 520 imaging measurements were made. The soft tissues were subsequently removed from the cadaver heads and the measurements were repeated using an electromagnetic 3 Space(TM) digitizer. Results: The results demonstrated no statistically significant difference between interobserver and intraobserver measurements or between imaging and physical measurements in both 3D-CT protocols. The standard error was found to be between 0.45% and 1.44% for all the measurements in both protocols, indicating a high level of precision. Furthermore, there was no statistically significant difference between imaging and physical measurements (P > 0.01). The error between the mean actual and mean 3D-based linear measurements was 0.83% for bone and 1.78% for soft tissue measurements, demonstrating high accuracy of both 3D-CT protocols. Conclusions: 3D-CT volume rendering images using craniometric measurements can be used for anthropological studies involving craniofacial applications.
引用
收藏
页码:170 / 176
页数:7
相关论文
共 50 条
  • [31] Occipital sutures and its variations: the value of 3D-CT and how to differentiate it from fractures using 3D-CT?
    Choudhary, Arabinda Kumar
    Jha, Bhawna
    Boal, Danielle K.
    Dias, Mark
    SURGICAL AND RADIOLOGIC ANATOMY, 2010, 32 (09) : 807 - 816
  • [32] Robust processing of intracranial CT angiograms for 3D volume rendering
    E. A. Moore
    J. P. Grieve
    H. R. Jäger
    European Radiology, 2001, 11 : 137 - 141
  • [33] Robust processing of intracranial CT angiograms for 3D volume rendering
    Moore, EA
    Grieve, JP
    Jäger, HR
    EUROPEAN RADIOLOGY, 2001, 11 (01) : 137 - 141
  • [34] 3D volume rendering using multislice CT for dental implants
    Cavalcanti, MGP
    Ruprecht, A
    Vannier, MW
    DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (04) : 218 - 223
  • [35] Occipital sutures and its variations: the value of 3D-CT and how to differentiate it from fractures using 3D-CT?
    Arabinda Kumar Choudhary
    Bhawna Jha
    Danielle K. Boal
    Mark Dias
    Surgical and Radiologic Anatomy, 2010, 32 : 807 - 816
  • [36] Analysis of sphenoid sinus and ethmoid sinus volume and asymmetry by sex: A 3D-CT study
    Nihal Gurlek Celik
    Burcu Akman
    Surgical and Radiologic Anatomy, 2024, 46 : 551 - 558
  • [37] Trends in oncological CT imaging: Clinical application of multidetector-row CT and 3D-CT imaging
    Ueda T.
    Mori K.
    Minami M.
    Motoori K.
    Ito H.
    International Journal of Clinical Oncology, 2006, 11 (4) : 268 - 277
  • [38] Analysis of sphenoid sinus and ethmoid sinus volume and asymmetry by sex: A 3D-CT study
    Celik, Nihal Gurlek
    Akman, Burcu
    SURGICAL AND RADIOLOGIC ANATOMY, 2024, 46 (05) : 551 - 558
  • [39] Detection of tracheal injury by helical CT and 3D-CT (3D-tracheography)
    Moriwaki, Y
    Sugiyama, M
    Matsuda, G
    Yoshida, K
    Hasegawa, S
    Karube, N
    Kosuge, T
    Uchida, K
    Yamamoto, T
    INTENSIVE CARE MEDICINE, 2001, 27 : S274 - S274
  • [40] Farbkodierte 3D-CT bei Pathologien am und im FelsenbeinColorcoded 3D-CT for pathologies in and around the petrous bone
    E. Elolf
    M. Tatagiba
    M. Samii
    Klinische Neuroradiologie, 1997, 7 (2) : 72 - 76