Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications

被引:134
|
作者
Cavalcanti, MGP
Rocha, SS
Vannier, MW
机构
[1] Univ Sao Paulo, Coll Dent, Dept Radiol, BR-05508900 Sao Paulo, Brazil
[2] Univ Iowa, Coll Med, Dept Radiol, Iowa City, IA 52242 USA
[3] Univ Sao Paulo, Coll Dent, Depr Forens Odontol, Sao Paulo, Brazil
关键词
tomography; X-ray computed; head; computer-assisted; image processing;
D O I
10.1259/dmfr/13603271
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study was designed to determine the precision and accuracy of anthropometric measurements using three-dimensional computed tomography (3D-CT) volume rendering by computer systems for craniofacial clinical applications, and to compare the craniometric landmarks using bone and soft tissue protocols. Methods: The study population consisted of 13 cadaver heads that were examined with spiral CT. The archived CT data were transferred to a workstation, and 3D-CT volume rendered images were generated using computer graphics tools. Linear measurements (n = 10), based upon conventional craniometric anatomical landmarks (n = 08), were identified in 2D-CT and in 3D-CT images by two radiologists twice each independently, and then performed by 3D-CT imaging using a computer graphics systems using bone and soft tissue protocols. In total, 520 imaging measurements were made. The soft tissues were subsequently removed from the cadaver heads and the measurements were repeated using an electromagnetic 3 Space(TM) digitizer. Results: The results demonstrated no statistically significant difference between interobserver and intraobserver measurements or between imaging and physical measurements in both 3D-CT protocols. The standard error was found to be between 0.45% and 1.44% for all the measurements in both protocols, indicating a high level of precision. Furthermore, there was no statistically significant difference between imaging and physical measurements (P > 0.01). The error between the mean actual and mean 3D-based linear measurements was 0.83% for bone and 1.78% for soft tissue measurements, demonstrating high accuracy of both 3D-CT protocols. Conclusions: 3D-CT volume rendering images using craniometric measurements can be used for anthropological studies involving craniofacial applications.
引用
收藏
页码:170 / 176
页数:7
相关论文
共 50 条
  • [21] Volume rendering of CT data: Applications to the genitourinary tract
    Sommer, FG
    Olcott, EW
    Chen, I
    Beaulieu, CF
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) : 1223 - 1226
  • [22] SUITABLE MESH FOR ADULT GROIN HERNIA TEP REPAIR BASED ON PELVIC 3D-CT SCAN MEASUREMENTS
    Zuiki, T.
    Oki, J.
    Ui, T.
    Hayakawa, S.
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [23] Clinical evaluation of 3D-CT cholangiography for preoperative examination in laparoscopic cholecystectomy
    Shinichi Kinami
    Tadashi Yao
    Madoka Kurachi
    Yoshio Ishizaki
    Journal of Gastroenterology, 1999, 34 : 111 - 118
  • [24] Assessment of the stylohoid chain by 3D-CT
    Ramadan, Selma Uysal
    Gokharman, Dilek
    Tuncbilek, Isil
    Kacar, Mahmut
    Kosar, Pinar
    Kosar, Ugur
    SURGICAL AND RADIOLOGIC ANATOMY, 2007, 29 (07) : 583 - 588
  • [25] Clinical evaluation of 3D-CT cholangiography for preoperative examination in laparoscopic cholecystectomy
    Kinami, S
    Yao, T
    Kurachi, M
    Ishizaki, Y
    JOURNAL OF GASTROENTEROLOGY, 1999, 34 (01) : 111 - 118
  • [26] A CNN-Based Approach for Lung 3D-CT Registration
    Hu, Xiaokun
    Yang, Jimin
    Yang, Juan
    IEEE ACCESS, 2020, 8 : 192835 - 192843
  • [27] 3D-CT ANGIOGRAPHY OF CEREBRAL ANEURYSMS
    LEBLANC, R
    TAMPIERI, D
    OLESZEK, J
    POKRUPA, R
    VILLEMURE, JG
    STROKE, 1995, 26 (01) : 174 - 174
  • [28] 3D-CT - Study of the skull base
    Avataneo, T
    Liboni, W
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 154 - 157
  • [29] 3D-CT evaluation of facial asymmetry
    Katsumata, A
    Fujishita, M
    Maeda, M
    Ariji, Y
    Ariji, E
    Langlais, RP
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2005, 99 (02): : 212 - 220
  • [30] Assessment of the stylohoid chain by 3D-CT
    Selma Uysal Ramadan
    Dilek Gokharman
    Işil Tunçbilek
    Mahmut Kacar
    Pinar Koşar
    Uğur Kosar
    Surgical and Radiologic Anatomy, 2007, 29 : 583 - 588