Interplatform Reproducibility of Liver and Spleen Stiffness Measured With MR Elastography

被引:55
|
作者
Yasar, Temel Kaya [2 ]
Wagner, Mathilde [2 ]
Bane, Octavia [2 ]
Besa, Cecilia [1 ,2 ]
Babb, James S. [3 ]
Kannengiesser, Stephan [4 ]
Fung, Maggie [5 ]
Ehman, Richard L. [6 ]
Taouli, Bachir [1 ,2 ]
机构
[1] Icahn Sch Med Mt Sinai, Dept Radiol, One Gustave Levy Pl,Box 1234, New York, NY 10029 USA
[2] Icahn Sch Med Mt Sinai, Translat & Mol Imaging Inst, One Gustave Levy Pl,Box 1234, New York, NY 10029 USA
[3] NYU, Dept Radiol, 560 1St Ave, New York, NY 10016 USA
[4] Siemens Med Solut, MR Applicat Dev, Erlangen, Germany
[5] GE Healthcare, MR Applicat & Workflow, New York, NY USA
[6] Mayo Clin, Dept Radiol, Rochester, MN USA
基金
美国国家卫生研究院;
关键词
MAGNETIC-RESONANCE ELASTOGRAPHY; VISCOELASTICITY MODEL IDENTIFICATION; CHRONIC HEPATITIS-C; TRANSIENT ELASTOGRAPHY; PORTAL-HYPERTENSION; NONINVASIVE ASSESSMENT; ESOPHAGEAL-VARICES; 3.0; T; VIRAL-HEPATITIS; SHEAR-WAVE;
D O I
10.1002/jmri.25077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess interplatform reproducibility of liver stiffness (LS) and spleen stiffness (SS) measured with magnetic resonance elastography (MRE) based on a 2D gradient echo (GRE) sequence. Materials and Methods: This prospective Health Insurance Portability and Accountability Act (HIPAA)-compliant and Institutional Review Board (IRB)-approved study involved 12 subjects (five healthy volunteers and seven patients with liver disease). A multislice 2D-GRE-based MRE sequence was performed using two systems from different vendors (3.0T GE and 1.5T Siemens) on the same day. Two independent observers measured LS and SS on confidence maps. Bland-Altman analysis (with coefficient of reproducibility, CR), coefficient of variability (CV), and intraclass correlation (ICC) were used to analyze interplatform, intra- and interobserver variability. Human data were validated using a gelatin-based phantom. Results: There was excellent reproducibility of phantom stiffness measurement (CV 4.4%). Mean LS values were 3.44-3.48 kPa and 3.62-3.63 kPa, and mean SS values were 7.54-7.91 kPa and 8.40-8.85 kPa at 3.0T and 1.5T for observers 1 and 2, respectively. The mean CVs between platforms were 9.2%-11.5% and 13.1%-14.4% for LS and SS, respectively, for observers 1 and 2. There was excellent interplatform reproducibility (ICC >0.88 and CR <36.2%) for both LS and SS, and excellent intra- and interobserver reproducibility (intraobserver: ICC >0.99, CV <2.1%, CR <6.6%; interobserver: ICC >0.97, CV and CR <16%). Conclusion: This study demonstrates that 2D-GRE MRE provides platform- and observer-independent LS and SS measurements.
引用
收藏
页码:1064 / 1072
页数:9
相关论文
共 50 条
  • [41] Learning curve and interobserver reproducibility evaluation of liver stiffness measurement by transient elastography
    Boursler, Jerome
    Konate, Anselme
    Guilluy, Marine
    Gorea, Gabriella
    Sawadogo, Apollinalre
    Quemener, Emmanuel
    Oberti, Frederic
    Reaud, Stephane
    Hubert-Fouchard, Isabelle
    Dib, Nina
    Cales, Paul
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2008, 20 (07) : 693 - 701
  • [42] The effect of the respiratory cycle on liver stiffness values as measured by transient elastography
    Yun, M. H.
    Seo, Y. S.
    Kang, H. S.
    Lee, K. G.
    Kim, J. H.
    An, H.
    Yim, H. J.
    Keum, B.
    Jeen, Y. T.
    Lee, H. S.
    Chun, H. J.
    Um, S. H.
    Kim, C. D.
    Ryu, H. S.
    JOURNAL OF VIRAL HEPATITIS, 2011, 18 (09) : 631 - 636
  • [43] Effect of breath holding at the end of the inspiration and expiration phases on liver stiffness measured by 2D-MR elastography
    Hao Ren
    Dawei Yang
    Hui Xu
    Kai Pang
    Yiwen Shi
    Qiushuang Guan
    Zhenghan Yang
    Abdominal Radiology, 2021, 46 : 2516 - 2526
  • [44] Effect of breath holding at the end of the inspiration and expiration phases on liver stiffness measured by 2D-MR elastography
    Ren, Hao
    Yang, Dawei
    Xu, Hui
    Pang, Kai
    Shi, Yiwen
    Guan, Qiushuang
    Yang, Zhenghan
    ABDOMINAL RADIOLOGY, 2021, 46 (06) : 2516 - 2526
  • [45] Nondiseased Liver Stiffness Measured by Shear Wave Elastography A Pilot Study
    Cha, Seung Woo
    Jeong, Woo Kyoung
    Kim, Yongsoo
    Kim, Min Yeong
    Kim, Jinoo
    Kim, Soo Yeon
    Ryu, Jeong Ah
    Kim, Tae Yeob
    Sohn, Joo Hyun
    Kim, Young Hwan
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (01) : 53 - 60
  • [46] Point Shear Wave Elastography of the Spleen in Predicting the Presence of Esophageal Varices in Cirrhosis: Liver Stiffness vs. Spleen Stiffness
    Sindhu, Nadella
    Koteshwar, Prakashini
    Shetty, Shiran
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2020, 36 (02) : 95 - 101
  • [47] Magnetic Resonance Elastography of Liver in Healthy Asians: Normal Liver Stiffness Quantification and Reproducibility Assessment
    Venkatesh, Sudhakar K.
    Wang, Gang
    Teo, Lynette L. S.
    Ang, Bertrand W. L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (01) : 1 - 8
  • [48] Spleen stiffness in a healthy pediatric population undergoing liver magnetic resonance elastography
    Serai, Suraj D.
    Glenn, Alexandra
    Trout, Andrew T.
    Lerebo, Wondwossen T.
    Gee, Michael S.
    Khanna, Geetika
    Anupindi, Sudha A.
    PEDIATRIC RADIOLOGY, 2025, : 846 - 856
  • [49] Relationship between Shear Stiffness Measured by MR Elastography and Perfusion Metrics Measured by Perfusion CT of Meningiomas
    Takamura, T.
    Motosugi, U.
    Ogiwara, M.
    Sasaki, Y.
    Glaser, K. J.
    Ehman, R. L.
    Kinouchi, H.
    Onishi, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (07) : 1216 - 1222
  • [50] Magnetic Resonance Elastography of Liver: Influence of Intravenous Gadolinium Administration on Measured Liver Stiffness
    James Thomas Patrick Decourcy Hallinan
    Hind Saif Alsaif
    Aileen Wee
    Sudhakar Kundapur Venkatesh
    Abdominal Imaging, 2015, 40 : 783 - 788