Interplatform Reproducibility of Liver and Spleen Stiffness Measured With MR Elastography

被引:55
|
作者
Yasar, Temel Kaya [2 ]
Wagner, Mathilde [2 ]
Bane, Octavia [2 ]
Besa, Cecilia [1 ,2 ]
Babb, James S. [3 ]
Kannengiesser, Stephan [4 ]
Fung, Maggie [5 ]
Ehman, Richard L. [6 ]
Taouli, Bachir [1 ,2 ]
机构
[1] Icahn Sch Med Mt Sinai, Dept Radiol, One Gustave Levy Pl,Box 1234, New York, NY 10029 USA
[2] Icahn Sch Med Mt Sinai, Translat & Mol Imaging Inst, One Gustave Levy Pl,Box 1234, New York, NY 10029 USA
[3] NYU, Dept Radiol, 560 1St Ave, New York, NY 10016 USA
[4] Siemens Med Solut, MR Applicat Dev, Erlangen, Germany
[5] GE Healthcare, MR Applicat & Workflow, New York, NY USA
[6] Mayo Clin, Dept Radiol, Rochester, MN USA
基金
美国国家卫生研究院;
关键词
MAGNETIC-RESONANCE ELASTOGRAPHY; VISCOELASTICITY MODEL IDENTIFICATION; CHRONIC HEPATITIS-C; TRANSIENT ELASTOGRAPHY; PORTAL-HYPERTENSION; NONINVASIVE ASSESSMENT; ESOPHAGEAL-VARICES; 3.0; T; VIRAL-HEPATITIS; SHEAR-WAVE;
D O I
10.1002/jmri.25077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess interplatform reproducibility of liver stiffness (LS) and spleen stiffness (SS) measured with magnetic resonance elastography (MRE) based on a 2D gradient echo (GRE) sequence. Materials and Methods: This prospective Health Insurance Portability and Accountability Act (HIPAA)-compliant and Institutional Review Board (IRB)-approved study involved 12 subjects (five healthy volunteers and seven patients with liver disease). A multislice 2D-GRE-based MRE sequence was performed using two systems from different vendors (3.0T GE and 1.5T Siemens) on the same day. Two independent observers measured LS and SS on confidence maps. Bland-Altman analysis (with coefficient of reproducibility, CR), coefficient of variability (CV), and intraclass correlation (ICC) were used to analyze interplatform, intra- and interobserver variability. Human data were validated using a gelatin-based phantom. Results: There was excellent reproducibility of phantom stiffness measurement (CV 4.4%). Mean LS values were 3.44-3.48 kPa and 3.62-3.63 kPa, and mean SS values were 7.54-7.91 kPa and 8.40-8.85 kPa at 3.0T and 1.5T for observers 1 and 2, respectively. The mean CVs between platforms were 9.2%-11.5% and 13.1%-14.4% for LS and SS, respectively, for observers 1 and 2. There was excellent interplatform reproducibility (ICC >0.88 and CR <36.2%) for both LS and SS, and excellent intra- and interobserver reproducibility (intraobserver: ICC >0.99, CV <2.1%, CR <6.6%; interobserver: ICC >0.97, CV and CR <16%). Conclusion: This study demonstrates that 2D-GRE MRE provides platform- and observer-independent LS and SS measurements.
引用
收藏
页码:1064 / 1072
页数:9
相关论文
共 50 条
  • [31] Effects of alcohol and abstinence on liver stiffness as measured by transient elastography
    Wu, Y.
    Weltman, M.
    Eslick, G. D.
    Pokorski, I.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2015, 30 : 187 - 187
  • [32] Evaluation of liver and spleen stiffness measurement with shear wave elastography in brucellosis
    Dogan, Ferit
    Celik, Mehmet
    Cosandal, Betul Amasyali
    Turac, Burak
    Ceylan, Mehmet Resat
    Dincer, Nevin Guler
    IRISH JOURNAL OF MEDICAL SCIENCE, 2024, 193 (03) : 1521 - 1526
  • [33] Assessment of liver fibrosis with liver and spleen stiffness measured by sound touch elastography, serum fibrosis markers in patients with chronic hepatitis B
    Dong, Bing Tian
    Huang, Shu
    Lyu, Guo Rong
    Qin, Ran
    Gu, Jiong Hui
    JOURNAL OF DIGESTIVE DISEASES, 2021, 22 (06) : 342 - 350
  • [34] LIVER STIFFNESS BUT NOT SPLEEN STIFFNESS MEASURED BY ACOUSTIC RADIATION FORCE IMPULSE ELASTOGRAPHY PREDICTED PROGNOSES IN PATIENTS WITH HEPATOCELLULAR CARCINOMA AFTER RADIOFREQUENCY ABLATION
    Su, Chien-Wei
    Lee, Pei-Chang
    Kao, Wei-Yu
    Lee, Kuei-Chuan
    Liang, Yuh-Jin
    Huang, Yi-Hsiang
    Hou, Ming-Chih
    Lin, Han-Chieh
    Wu, Jaw-Ching
    HEPATOLOGY, 2019, 70 : 238A - 239A
  • [35] Editorial for "Reproducibility of Cardiac Multifrequency MR Elastography in Assessing Left Ventricular Stiffness and Viscosity"
    Sakhi, Hichem
    Chevance, Virgile
    Azarine, Arshid
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024,
  • [36] Relationship between Cerebral Vasculature and Brain Stiffness Measured Using MR Elastography
    Alshareef, Ahmed
    Johnson, Curtis L.
    Carass, Aaron
    Knutsen, Andrew K.
    Delgorio, Peyton L.
    McIlvain, Grace
    Diano, Alexa M.
    Ramesh, K. T.
    Bayly, Phillip, V
    Pham, Dzung L.
    Prince, Jerry L.
    MEDICAL IMAGING 2022: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2022, 12036
  • [37] The relationship of spleen stiffness value measured by shear wave elastography with age, gender, and spleen size in healthy volunteers
    Albayrak, Eda
    Server, Sadik
    JOURNAL OF MEDICAL ULTRASONICS, 2019, 46 (02) : 195 - 199
  • [38] The relationship of spleen stiffness value measured by shear wave elastography with age, gender, and spleen size in healthy volunteers
    Eda Albayrak
    Sadık Server
    Journal of Medical Ultrasonics, 2019, 46 : 195 - 199
  • [39] FEASIBILITY AND REPRODUCIBILITY OF LIVER STIFFNESS (LSM) BY POINT SHEAR-WAVE ELASTOGRAPHY
    Baccarin, A.
    Fraquelli, M.
    Casazza, G.
    Conti, C. B.
    Pozzi, R.
    Massironi, S.
    Aghemo, A.
    Donato, F.
    Conte, D.
    Colombo, M.
    DIGESTIVE AND LIVER DISEASE, 2015, 47 : E205 - E205
  • [40] Liver stiffness measurement by transient elastography:: Predictive factors of accuracy, success and reproducibility
    Konate, Anselme
    Boursier, Jerome
    Reaud, Stephane
    Quemener, Emmanuel
    Fouchard-Hubert, Isabelle
    Oberti, Frederic
    Cales, Paul
    HEPATOLOGY, 2006, 44 (04) : 452A - 452A