Histogram clustering for rapid time-domain fluorescence lifetime image analysis

被引:3
|
作者
Li, Yahui [1 ,2 ]
Sapermsap, Natakorn [3 ]
Yu, Jun [4 ]
Tian, Jinshou [1 ,2 ]
Chen, Yu [3 ]
Li, David Day-Uei [5 ]
机构
[1] Xian Inst Opt & Precis Mech, Key Lab Ultrafast Photoelect Diagnost Technol, Xian 710049, Shaanxi, Peoples R China
[2] Shanxi Univ, Collaborat Innovat Ctr Extreme Opt, Taiyuan 030006, Shanxi, Peoples R China
[3] Univ Strathclyde, Scottish Univ Phys Alliance, Dept Phys, Glasgow G4 0NG, Lanark, Scotland
[4] Univ Strathclyde, Strathclyde Inst Pharm & Biomed Sci, Glasgow G4 0RE, Lanark, Scotland
[5] Univ Strathclyde, Dept Biomed Engn, Glasgow G1 0NW, Lanark, Scotland
基金
中国国家自然科学基金; 英国工程与自然科学研究理事会; 英国生物技术与生命科学研究理事会; 中国科学院基金;
关键词
DECONVOLUTION; IMPLEMENTATION; DYNAMICS; SYSTEM;
D O I
10.1364/BOE.427532
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorescence lifetime imaging (FLIM) [1] is a crucial technique for assessing microenvironments of fluorophores, such as pH, Ca2+, O2, viscosity, or temperature [2-5]. Combining with Forster Resonance Energy Transfer (FRET) techniques [6], FLIM can be a powerful "quantum ruler" to measure protein conformations and interactions [7]. In contrast to fluorescence intensity imaging, FLIM is independent of fluorescence intensities and fluorophore concentrations, making FLIM a robust quantitative imaging technique for life sciences applications [8,9], medical diagnosis [10], drug developments [11,12], and flow diagnosis [13-15]. A fluorescence decay is usually modeled as a sum of exponential decay functions: We propose a histogram clustering (HC) method to accelerate fluorescence lifetime imaging (FLIM) analysis in pixel-wise and global fitting modes. The proposed method's principle was demonstrated, and the combinations of HC with traditional FLIM analysis were explained. We assessed HC methods with both simulated and experimental datasets. The results reveal that HC not only increases analysis speed (up to 106 times) but also enhances lifetime estimation accuracy. Fast lifetime analysis strategies were suggested with execution times around or below 30 mu s per histograms on MATLAB R2016a, 64-bit with the Intel Celeron CPU (2950M @ 2GHz).
引用
收藏
页码:4293 / 4307
页数:15
相关论文
共 50 条
  • [41] Sampling and Time-Domain Analysis
    Brandt, Anders
    Ahlin, Kjell
    [J]. SOUND AND VIBRATION, 2010, 44 (05): : 13 - 17
  • [42] TIME-DOMAIN RAY ANALYSIS
    CRONSON, HM
    PROUD, JM
    [J]. PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1970, 58 (09): : 1383 - &
  • [43] Time- and frequency-domain analysis of fluorescence lifetime for temperature sensors
    Fernicola, VC
    Rosso, L
    [J]. 2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 587 - 588
  • [44] A direct approach to time domain fluorescence tomography based on asymptotic lifetime analysis
    Kumar, Anand T. N.
    Raymond, Scott B.
    Boas, David A.
    Bacskai, Brian J.
    [J]. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VII, 2007, 6434
  • [45] A linear, featured-data scheme for image reconstruction in time-domain fluorescence molecular tomography
    Gao, Feng
    Zhao, Huijuan
    Tanikawa, Yukari
    Yamada, Yukio
    [J]. OPTICS EXPRESS, 2006, 14 (16): : 7109 - 7124
  • [46] EFFECT OF LIFETIME CIGARETTE CONSUMPTION ON TIME-DOMAIN SPIROGRAM INDEXES
    NAKADATE, T
    SATO, T
    KAGAWA, J
    YAGAMI, T
    [J]. INDUSTRIAL HEALTH, 1994, 32 (01) : 29 - 40
  • [47] Reconstruction of absorption and fluorescence contrast for scanning time-domain fluorescence mammography
    Ziegler, Ronny
    Nielsen, Tim
    Koehler, Thomas
    Grosenick, Dirk
    Steinkellner, Oliver
    Hagen, Axel
    Macdonald, Rainer
    Rinneberg, Herbert
    [J]. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VII, 2007, 6434
  • [48] INEQUIVALENCE OF FLUORESCENT CHOLINE AND ETHANOLAMINE PHOSPHOLIPIDS IN THE ERYTHROCYTE-MEMBRANE - FLUORESCENCE LIFETIME DETERMINATION IN THE FREQUENCY AND TIME-DOMAIN
    PRENNER, E
    SOMMER, A
    KUNGL, A
    STUTZ, H
    FRIEDL, H
    HERMETTER, A
    [J]. ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1993, 305 (02) : 473 - 476
  • [49] Linear scheme for time-domain fluorescence molecular tomography
    高峰
    刘维
    赵会娟
    [J]. Chinese Optics Letters, 2006, (10) : 595 - 597
  • [50] A Rapid-Acquisition Electrical Time-Domain Reflectometer for Dynamic Structure Analysis
    Bishop, Joseph A.
    Pommerenke, David J.
    Chen, Genda
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (02) : 655 - 661