Numerical evaluation of the plastic hinges developed in headed stud shear connectors in composite beams with profiled steel sheeting

被引:8
|
作者
Vigneri, V. [1 ]
Odenbreit, C. [1 ]
Braun, M. [1 ]
机构
[1] Univ Luxembourg, ArcelorMittal Chair Steel & Facade, Luxembourg, Luxembourg
关键词
Push-out test; Shear stud; Mechanical model; Numerical model; Shear connector with profiled sheeting; SLABS;
D O I
10.1016/j.istruc.2019.03.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
For composite beams using novel steel sheeting, the current Eurocode 4 rules sometimes overestimate the loadbearing capacity of headed stud shear connectors. This is due to the larger rib heights and the smaller rib widths in comparison with the old studies, which have been carried out to calibrate the current design equations. The RFCS Project "DISCCO" investigated this phenomena and the working group under mandate M515, CEN/TC250/ SC4/SC4.T3 is enhancing this equation and working on a proposal to be taken over in the new version of Eurocode 4. The proposed new equation covers the failure behaviour of the shear connection more in detail. The test results show, that the failure consists in a combined concrete cone and stud in bending. Due to the geometry of novel steel sheeting, the load bearing capacity of the headed stud shear connector is no more limited by its shear capacity, but by its bending capacity. A 3D non-linear finite element model is developed and validated through the support of the DISCCO push-out tests. A good agreement between numerical and experimental results in terms of force-slip behaviour is achieved. Special attention of this work lies on the numerical evaluation of the number of plastic hinges n(y): a stress-based procedure is presented and the results are compared to the equations presented for new Eurocode 4. The numerical simulations show that the upper plastic hinge moves up as the slip increases due to the progressive crushing of the concrete in the rib. From the parametric study, it turns out that n(y) is linearly proportional to the embedment depth. Compared to pre-punched hole decking, through-deck welding specimen activates less plastic hinges in the studs because of the higher stiffness provided at the base of the stud.
引用
收藏
页码:103 / 110
页数:8
相关论文
共 50 条
  • [21] Performance and design of shear connectors in composite beams with parallel profiled sheeting at elevated temperatures
    Ling-Zhu Chen
    Gianluca Ranzi
    Shou-Chao Jiang
    Faham Tahmasebinia
    Guo-Qiang Li
    International Journal of Steel Structures, 2016, 16 : 217 - 229
  • [22] Performance and design of shear connectors in composite beams with parallel profiled sheeting at elevated temperatures
    Chen, Ling-Zhu
    Ranzi, Gianluca
    Jiang, Shou-Chao
    Tahmasebinia, Faham
    Li, Guo-Qiang
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2016, 16 (01) : 217 - 229
  • [23] Experimental and Numerical Analyses of Stud Shear Connectors in Steel-SFRCC Composite Beams
    Peng, Kai
    Liu, Laijun
    Wu, Fangwen
    Wang, Ruizheng
    Lei, Song
    Zhang, Xiaoyu
    MATERIALS, 2022, 15 (13)
  • [24] Reliability analysis of shear connection in composite beams with profiled steel sheeting
    Youcef, M. Ait
    Mimoune, M.
    Mimoune, F. Z.
    WORLD JOURNAL OF ENGINEERING, 2011, 8 (01) : 29 - 33
  • [25] PARTIAL-INTERACTION ANALYSIS OF COMPOSITE BEAMS WITH PROFILED SHEETING AND NONWELDED SHEAR CONNECTORS
    CRISINEL, M
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1990, 15 (1-2) : 65 - 98
  • [26] BEHAVIOUR OF HEADED STUD SHEAR CONNECTORS FOR COMPOSITE STEEL-CONCRETE BEAMS INCORPORATING RECYCLED CONCRETE
    Deo, Vivit Nehaal
    Tan, Ee Loon
    Tam, Vivian
    PROCEEDINGS OF THE THIRTEENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS 1 AND II, 2014, : 66 - 73
  • [27] EFFECTS OF STRAIN REGIMES ON THE BEHAVIOUR OF HEADED STUD SHEAR CONNECTORS FOR COMPOSITE STEEL-CONCRETE BEAMS
    Mirza, O.
    Uy, B.
    ADVANCED STEEL CONSTRUCTION, 2010, 6 (01): : 635 - 661
  • [28] Existing rules and new tests for stud shear connectors in troughs of profiled sheeting
    Johnson, RP
    Yuan, H
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1998, 128 (03) : 244 - 251
  • [29] Fire performance of headed shear studs in profiled steel sheeting
    Lim, Ohk Kun
    Choi, Sengkwan
    Kang, Sungwook
    Kwon, Minjae
    Choi, J. Yoon
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 164
  • [30] Experimental studies of headed stud shear connectors in UHPC Steel composite slabs
    Gao, Xiao-Long
    Wang, Jun-Yan
    Yan, Jia-Bao
    STRUCTURAL ENGINEERING AND MECHANICS, 2020, 74 (05) : 657 - 670