Frequency-selective signal enhancement by a passive dual coil resonator for magnetic particle imaging

被引:9
|
作者
Pantke, Dennis [1 ]
Mueller, Florian [1 ]
Reinartz, Sebastian [2 ]
Philipps, Jonas [1 ]
Dadfar, Seyed Mohammadali [3 ]
Peters, Maximilian [1 ]
Franke, Jochen [1 ,4 ]
Schrank, Franziska [1 ]
Kiessling, Fabian [3 ,5 ]
Schulz, Volkmar [1 ,5 ,6 ]
机构
[1] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, Dept Phys Mol Imaging, Aachen, Germany
[2] Uniklin RWTH Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[3] Rhein Westfal TH Aachen, Med Fac, Inst Expt Mol Imaging, Aachen, Germany
[4] Bruker BioSpin MRI GmbH, Preclin Imaging Div, Ettlingen, Germany
[5] Fraunhofer Inst Digital Med MEVIS, Bremen, Germany
[6] Rhein Westfal TH Aachen, Phys Inst B 3, Aachen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2022年 / 67卷 / 11期
关键词
magnetic particle imaging; passive receive coil; signal enhancement; SYSTEM; RECONSTRUCTION; HYPERTHERMIA; FEASIBILITY; FORMULATION; RESOLUTION;
D O I
10.1088/1361-6560/ac6a9f
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Magnetic particle imaging (MPI) visualizes the spatial distribution of magnetic nanoparticles. MPI already provides excellent temporal and good spatial resolution, however, to achieve translation into clinics, further advances in the fields of sensitivity, image reconstruction and tracer performance are needed. In this work, we propose a novel concept to enhance the MPI signal and image resolution by a purely passive receive coil insert for a preclinical MPI system. Approach. The passive dual coil resonator (pDCR) provides frequency-selective signal enhancement. This is enabled by the adaptable resonance frequency of the pDCR network, which is galvanically isolated from the MPI system and composed of two coaxial solenoids connected via a capacitor. The pDCR aims to enhance frequency components related to high mixing orders, which are crucial to achieve high spatial resolution. Main Results. In this study, system matrix measurements and image acquisitions of a resolution phantom are carried out to evaluate the performance of the pDCR compared to the integrated receive unit of the preclinical MPI and a dedicated rat-sized receive coil. Frequency-selective signal increase and spatial resolution enhancement are demonstrated. Significance. Common dedicated receive coils come along with noise-matched receive networks, which makes them costly and difficult to reproduce. The presented pDCR is a purely passive coil insert that gets along without any additional receive electronics. Therefore, it is cost-efficient, easy-to-handle and adaptable to other MPI scanners and potentially other applications providing the basis for a new breed of passive MPI receiver systems.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Diversity technique for DAPSK signal over the frequency-selective fading channel
    Lee, JY
    Chung, YM
    Lee, SU
    APOC 2001: ASIA-PACIFIC OPTICAL AND WIRELESS COMMUNICATIONS: WIRELESS AND MOBILE COMMUNICATIONS, 2001, 4586 : 179 - 189
  • [42] Optimal periodic training signal for frequency offset estimation in frequency-selective fading channels
    Minn, Hlaing
    Fu, Xiaoyu
    Bhargava, Vijay K.
    IEEE TRANSACTIONS ON COMMUNICATIONS, 2006, 54 (06) : 1081 - 1096
  • [43] Frequency-selective analysis of multichannel magnetic resonance spectroscopy data
    Sandgren, Niclas
    Stoica, Petre
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 2371 - 2374
  • [44] Frequency-selective quantification of biomedical magnetic resonance spectroscopy data
    Vanhamme, L
    Sundin, T
    Van Hecke, P
    Van Huffel, S
    Pintelon, R
    JOURNAL OF MAGNETIC RESONANCE, 2000, 143 (01) : 1 - 16
  • [45] Asynchronous Signal Detection in Frequency-Selective Non-Gaussian Channels
    Amuru, SaiDhiraj
    Jakubisin, Daniel
    Buehrer, R. Michael
    da Silva, Claudio R. C. M.
    2013 ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS AND COMPUTERS, 2013, : 2103 - 2107
  • [46] An improved particle swarm optimization algorithm for frequency-selective surface design
    Xianjun Sheng
    Xiang Gao
    Ning Liu
    Indian Journal of Physics, 2020, 94 : 1909 - 1915
  • [47] Frequency-selective control of ferromagnetic resonance linewidth in magnetic multilayers
    Schaefer, S.
    Pachauri, N.
    Mewes, C. K. A.
    Mewes, T.
    Kaiser, C.
    Leng, Q.
    Pakala, M.
    APPLIED PHYSICS LETTERS, 2012, 100 (03)
  • [48] DYNAMIC CHARACTERISTICS OF FERROMAGNETIC FREQUENCY-SELECTIVE SYSTEMS WITH MAGNETIC RETUNING
    BOGDANOV, GB
    RADIO ENGINEERING AND ELECTRONIC PHYSICS-USSR, 1968, 13 (05): : 827 - &
  • [49] An Improved Design of Detection Coil for Magnetic Particle Imaging
    Zhang, Rui
    Sun, Shijie
    Sun, Shaoqi
    Wei, Jian
    Li, Xingang
    Zhong, Jing
    Xu, Lijun
    2023 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC, 2023,
  • [50] Narrowband Passive RF Tags for Frequency-Selective Harmonic Doppler Radar Tracking
    Hilton, Cory
    Nanzer, Jeffrey A.
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2023, 71 (02) : 1216 - 1222