Frequency-selective signal enhancement by a passive dual coil resonator for magnetic particle imaging

被引:9
|
作者
Pantke, Dennis [1 ]
Mueller, Florian [1 ]
Reinartz, Sebastian [2 ]
Philipps, Jonas [1 ]
Dadfar, Seyed Mohammadali [3 ]
Peters, Maximilian [1 ]
Franke, Jochen [1 ,4 ]
Schrank, Franziska [1 ]
Kiessling, Fabian [3 ,5 ]
Schulz, Volkmar [1 ,5 ,6 ]
机构
[1] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, Dept Phys Mol Imaging, Aachen, Germany
[2] Uniklin RWTH Aachen, Dept Diagnost & Intervent Radiol, Aachen, Germany
[3] Rhein Westfal TH Aachen, Med Fac, Inst Expt Mol Imaging, Aachen, Germany
[4] Bruker BioSpin MRI GmbH, Preclin Imaging Div, Ettlingen, Germany
[5] Fraunhofer Inst Digital Med MEVIS, Bremen, Germany
[6] Rhein Westfal TH Aachen, Phys Inst B 3, Aachen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2022年 / 67卷 / 11期
关键词
magnetic particle imaging; passive receive coil; signal enhancement; SYSTEM; RECONSTRUCTION; HYPERTHERMIA; FEASIBILITY; FORMULATION; RESOLUTION;
D O I
10.1088/1361-6560/ac6a9f
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Magnetic particle imaging (MPI) visualizes the spatial distribution of magnetic nanoparticles. MPI already provides excellent temporal and good spatial resolution, however, to achieve translation into clinics, further advances in the fields of sensitivity, image reconstruction and tracer performance are needed. In this work, we propose a novel concept to enhance the MPI signal and image resolution by a purely passive receive coil insert for a preclinical MPI system. Approach. The passive dual coil resonator (pDCR) provides frequency-selective signal enhancement. This is enabled by the adaptable resonance frequency of the pDCR network, which is galvanically isolated from the MPI system and composed of two coaxial solenoids connected via a capacitor. The pDCR aims to enhance frequency components related to high mixing orders, which are crucial to achieve high spatial resolution. Main Results. In this study, system matrix measurements and image acquisitions of a resolution phantom are carried out to evaluate the performance of the pDCR compared to the integrated receive unit of the preclinical MPI and a dedicated rat-sized receive coil. Frequency-selective signal increase and spatial resolution enhancement are demonstrated. Significance. Common dedicated receive coils come along with noise-matched receive networks, which makes them costly and difficult to reproduce. The presented pDCR is a purely passive coil insert that gets along without any additional receive electronics. Therefore, it is cost-efficient, easy-to-handle and adaptable to other MPI scanners and potentially other applications providing the basis for a new breed of passive MPI receiver systems.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Cavity resonator coil for high field magnetic resonance Imaging
    Solis, S. E.
    Tomasi, D.
    Rodriguez, A. O.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 3884 - 3885
  • [32] A Wideband Frequency-Selective Rasorber Based on Interdigital Resonator and Fractal Shaped Slot
    Sun, Ying
    Xiao, Shaoqiu
    Yao, Zhixin
    Shi, Qi
    2019 IEEE MTT-S INTERNATIONAL WIRELESS SYMPOSIUM (IWS 2019), 2019,
  • [33] Frequency-selective power transducers "hexagonal ferrite resonator-semiconductor element"
    Koledintseva, M. Y.
    PIERS 2006 Cambridge: Progress in Electromagnetics Research Symposium, Proceedings, 2006, : 241 - 245
  • [34] 2D Absorptive Frequency-Selective Transmission Structure with Slotted Resonator
    Wang, Peipei
    Ren, Wu
    Xue, Zhenghui
    Li, Weiming
    2022 INTERNATIONAL CONFERENCE ON MICROWAVE AND MILLIMETER WAVE TECHNOLOGY (ICMMT), 2022,
  • [35] Absorptive Frequency-Selective Transmission Structure With Square-Loop Hybrid Resonator
    Huang, Hao
    Shen, Zhongxiang
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2017, 16 : 3212 - 3215
  • [36] Design of Frequency-Selective Rasorbers Based on Centrosymmetric Bended-Strip Resonator
    Guo, Min
    Sun, Zhanshan
    Sang, Di
    Jia, Xueqing
    Fu, Yunqi
    IEEE ACCESS, 2019, 7 : 24964 - 24970
  • [37] Signal Separation in Magnetic Particle Imaging
    Graeser, Matthias
    Knopp, Tobias
    Sattel, Timo F.
    Gruettner, Mandy
    Buzug, Thorsten M.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2483 - 2485
  • [38] Frequency-selective imaging of acoustic vibration components by photorefractive interferometry
    Xiong, Jichuan
    Glorieux, Christ
    INTERNATIONAL CONGRESS ON ULTRASONICS (GDANSK 2011), 2012, 1433 : 121 - 124
  • [39] DETECTION OF FREQUENCY-SELECTIVE FADING SIGNAL IN THE UNKNOWN-SPECTRUM NOISES
    SAVINA, AI
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 1980, 23 (04): : 93 - 95
  • [40] An improved particle swarm optimization algorithm for frequency-selective surface design
    Sheng, Xianjun
    Gao, Xiang
    Liu, Ning
    INDIAN JOURNAL OF PHYSICS, 2020, 94 (12) : 1909 - 1915