Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of boron in plant tissues

被引:34
|
作者
Resano, M. [1 ]
Briceno, J. [1 ]
Aramendia, M. [1 ]
Belarra, M. A. [1 ]
机构
[1] Univ Zaragoza, Dept Analyt Chem, E-50009 Zaragoza, Spain
关键词
solid sampling; graphite furnace atomic absorption spectrometry; boron determination; tungsten permanent modifier; citric acid;
D O I
10.1016/j.aca.2006.09.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, the potential of graphite furnace atomic absorption spectrometry for the direct determination of B in plant tissues has been investigated. Three certified reference materials (NIST SRM 1570a spinach leaves, NIST SRM 1573a tomato leaves and BCR CRM 679 white cabbage) were selected for this study, the goal always being to develop a fast procedure that could be robust enough to provide a satisfactory performance for all of them, without any modifications in the conditions applied. The use of a suitable chemical modifier was found to be essential for obtaining a reproducible and sufficiently sensitive signal for boron solutions. In this regard, the performance of the combination of citric acid plus W (added as a permanent modifier) was noteworthy, resulting in well-defined signal profiles, a remarkable analyte stabilization during the pyrolysis step (up to 2100 degrees C) and minimal memory effects. This mixture of modifiers provided a good performance for the direct analysis of solid samples as well, but only if a suitable temperature program, favoring the interaction between the analyte and the modifiers, was used. Thus, such a temperature program, with two pyrolysis steps and the addition of NH4NO3 in order to carry out the in situ sample microdigestion, was optimized. Under these conditions, the peak areas obtained for both solid samples and aqueous standards were comparable. Finally, the analysis of the samples was carried out. In all cases, a good agreement with the certified values was obtained, while R.S.D. values ranged between 6 and 10%. It can be concluded that the method proposed shows significant advantages for the determination of this complicated element in solid samples such as the use of aqueous standards for calibration, a high sample throughput (20 min per sample), a suitable limit of detection (0.3 mu g g(-1)) and reduced risk of analyte losses and contamination. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:214 / 222
页数:9
相关论文
共 50 条
  • [41] Magnesium and calcium determination in desalted crude oil by direct sampling graphite furnace atomic absorption spectrometry
    Seeger, Tassia S.
    Muller, Edson I.
    Mesko, Marcia F.
    Duarte, Fabio A.
    FUEL, 2019, 236 : 1483 - 1488
  • [42] Determination of Dysprosium in Rock Vitrified with Lithium Tetraborate by Solid Sampling Graphite Furnace Atomic Absorption Spectrometry
    Araki, Toshimitsu
    Inui, Tetsuo
    Nakamura, Toshihiro
    BUNSEKI KAGAKU, 2015, 64 (08) : 595 - 600
  • [43] Determination of Cu and Cd content of groundwater colloids by solid sampling graphite furnace atomic absorption spectrometry
    Freedman, YE
    Ronen, D
    Long, GL
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (07) : 2270 - 2277
  • [44] Determination of manganese and nickel in slurry sampling by graphite furnace atomic absorption spectrometry
    Pereira, Luciano Almeida
    Borges, Simone Soares de O.
    Castro, Mauricio Costa
    Borges Neto, Waldomiro
    Windmoller, Claudia Carvalhinho
    Borba da Silva, Jose Bento
    CANADIAN JOURNAL OF CHEMISTRY, 2008, 86 (04) : 312 - 316
  • [45] Evaluation of solid sampling-electrothermal vaporization-inductively coupled plasma mass spectrometry and solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of Cr in various materials using solution-based calibration approaches
    Resano, M
    Garcia-Ruiz, E
    Vanhaecke, F
    Crespo, C
    Belarra, MA
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (08) : 958 - 965
  • [46] Evaluation of solid sampling-electrothermal vaporization-inductively coupled plasma mass spectrometry and solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of Cr in various materials using solution-based calibration approaches
    Resano, M.
    Garcia-Ruiz, E.
    Vanhaecke, F.
    Crespo, C.
    Belarra, M.A.
    Journal of Analytical Atomic Spectrometry, 2004, 19 (08): : 958 - 965
  • [47] Direct determination of copper and lead in sewage sludge by solid sampling-graphite furnace atomic absorption spectrometry - study of the interference reduction in the gaseous phase working in non-stop flow conditions
    Belarra, MA
    Crespo, C
    Resano, M
    Castillo, JR
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) : 865 - 874
  • [48] Trace element analysis of silicon nitride powders by direct solid sampling graphite furnace atomic absorption spectrometry
    Paz de Mattos, Julio Cezar
    Flores, Erico Marlon de Moraes
    Krivan, Viliam
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (07) : 931 - 937
  • [49] Trace element analysis of silicon nitride powders by direct solid sampling graphite furnace atomic absorption spectrometry
    De Mattos, Julio Cezar Paz
    De Moraes Flores, Érico Marlon
    Krivan, Viliam
    Journal of Analytical Atomic Spectrometry, 2008, 23 (07): : 931 - 937
  • [50] Determination of lead in coal using direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry
    Gallindo Borges, DL
    da Silva, AF
    Curtius, AJ
    Welz, B
    Heitmann, U
    MICROCHIMICA ACTA, 2006, 154 (1-2) : 101 - 107