Multi-slice computed tomography: A tool for non-invasive temperature measurement?

被引:25
|
作者
Bruners, Philipp [1 ,2 ]
Levit, Elena [1 ]
Penzkofer, Tobias [1 ,2 ]
Isfort, Peter [1 ,2 ]
Ocklenburg, Christina [3 ]
Schmidt, Bernhardt [4 ]
Schmitz-Rode, Thomas [2 ]
Guenther, Rolf W. [1 ]
Mahnken, Andreas H. [1 ]
机构
[1] Rhein Westfal TH Aachen, Univ Hosp, Dept Diagnost Radiol, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, Dept Appl Med Engn, Aachen, Germany
[3] Rhein Westfal TH Aachen, Univ Hosp, Inst Med Stat, D-52074 Aachen, Germany
[4] Siemens Med Solut, Forchheim, Germany
关键词
interventional radiology; computed tomography; thermometry; attenuation values; ablation techniques; RADIOFREQUENCY ABLATION; IN-VIVO; MICROWAVE ABLATION; MR THERMOMETRY; LIVER; CT; ULTRASOUND; HYPERTHERMIA; METASTASES; ARTIFACTS;
D O I
10.3109/02656731003605654
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the potential of multi-slice computed tomography (MSCT) as a tool for non-invasive temperature measurement. Materials and methods: Samples of water, 0.9% saline, sunflower oil and dilutions of (1:32, 1:64, 1:128) contrast agent (Iopromid 370, BayerSchering Pharma, Berlin) were heated in a plexiglass phantom. In a first set-up, samples of 0.9% saline solution were scanned at defined temperatures (25 degrees-75 degrees C; 5 degrees C intervals) using a clinical CT scanner. Scan parameters (tube current-time product, tube voltage, collimation, slice thickness) were systematically varied. In a second set-up samples of the different fluids (water, sunflower oil, contrast agent dilutions) were scanned using the following scan protocol: 250 mAs, 140 kV, 1.2 mm collimation, 9.6 mm slice thickness. CT numbers were measured in reconstructed axial images at the different temperatures. A regression analysis was performed to investigate the relationship between temperature and CT number. Results: Standard deviation of measured CT numbers decreased with increasing tube current-time product, increasing tube voltage, thicker collimation and higher slice thickness. Regression analysis showed an inverse relationship between temperature and CT number for all fluids with regression coefficients of -0.471 (0.9% saline), 0.447 (water), -0.679 (sunflower oil), -0.420 (contrast agent 1: 32), -0.414 (contrast agent 1: 64) and -0.441 (contrast agent 1: 128), respectively. Conclusion: Multi-slice computed tomography can depict thermal density expansion of different fluids. Based on these results the implementation of a temperature discrimination of several degrees C at a high spatial resolution is achievable.
引用
收藏
页码:359 / 365
页数:7
相关论文
共 50 条
  • [41] Biventricular non-compaction demonstrated on multi-slice computed tomography with echocardiographic correlation
    Grillone, Saverio
    Nucifora, Gaetano
    Piccoli, Gianluca
    Gianfagna, Pasquale
    Hysko, Fjoralba
    Pavoni, Daisy
    Slavich, Gianaugusto
    Proclemer, Alessandro
    Gasparini, Daniele
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2013, 14 (09) : 677 - 680
  • [42] Multi-slice computed tomography manifestations of hepatic epithelioid angiomyolipoma
    Chun-Lai Dai
    Li-Ping Xue
    Yu-Mei Li
    World Journal of Gastroenterology, 2014, (12) : 3364 - 3368
  • [43] Multi-slice computed tomography manifestations of hepatic epithelioid angiomyolipoma
    Dai, Chun-Lai
    Xue, Li-Ping
    Li, Yu-Mei
    WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (12) : 3364 - 3368
  • [44] Multi-slice computed tomography for diagnosis of combined thoracoabdominal injury
    Liu Jun
    Yue Weidong
    Du Dingyuan
    中华创伤杂志英文版, 2015, 18 (01) : 27 - 32
  • [45] Evaluation of intestinal tuberculosis by multi-slice computed tomography enterography
    Jing Zhao
    Min-Yi Cui
    Tao Chan
    Ren Mao
    Yanji Luo
    Indira Barua
    Minhu Chen
    Zi-Ping Li
    Shi-Ting Feng
    BMC Infectious Diseases, 15
  • [46] Multi-slice computed tomography in diagnostic of ischemic heart disease
    Chomahidze, PS
    Syrkin, AL
    Ternovoy, SK
    Sulimov, VA
    Pasha, SP
    Fominih, EV
    Gagarina, NV
    HEART, 2004, 90 : A15 - A15
  • [47] Role of multi-slice computed tomography in the recognition of pericardial cyst
    Mlynarski, Rafal
    Gardas, Rafal
    Mlynarska, Agnieszka
    Kargul, Wlodzimierz
    Tendera, Michal
    Sosnowski, Maciej
    CARDIOLOGY JOURNAL, 2011, 18 (01) : 90 - 91
  • [48] Usefulness of 64 multi-slice computed tomography in acute myopericarditis
    Shturman, Alexander
    Chernihovski, Anna
    Goldfeld, Moshe
    Furer, Ariel
    Wishniak, Alice
    Roguin, Nathan
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2007, 9 (04): : 333 - 334
  • [49] Characterisation of coronary artery fistula by multi-slice computed tomography
    Tan, Kiat T.
    Chamberlain-Webber, Rafe
    McGann, Garrett
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 111 (02) : 311 - 312
  • [50] Multi-slice computed tomography and the detection of anomalies of coronary arteries
    Ronnano, Silvia
    Morra, Aldo
    Del Borrello, Mario
    Greco, Pietro
    Daliento, Luciano
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2008, 9 (02) : 187 - 194