Multi-slice computed tomography: A tool for non-invasive temperature measurement?

被引:25
|
作者
Bruners, Philipp [1 ,2 ]
Levit, Elena [1 ]
Penzkofer, Tobias [1 ,2 ]
Isfort, Peter [1 ,2 ]
Ocklenburg, Christina [3 ]
Schmidt, Bernhardt [4 ]
Schmitz-Rode, Thomas [2 ]
Guenther, Rolf W. [1 ]
Mahnken, Andreas H. [1 ]
机构
[1] Rhein Westfal TH Aachen, Univ Hosp, Dept Diagnost Radiol, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, Dept Appl Med Engn, Aachen, Germany
[3] Rhein Westfal TH Aachen, Univ Hosp, Inst Med Stat, D-52074 Aachen, Germany
[4] Siemens Med Solut, Forchheim, Germany
关键词
interventional radiology; computed tomography; thermometry; attenuation values; ablation techniques; RADIOFREQUENCY ABLATION; IN-VIVO; MICROWAVE ABLATION; MR THERMOMETRY; LIVER; CT; ULTRASOUND; HYPERTHERMIA; METASTASES; ARTIFACTS;
D O I
10.3109/02656731003605654
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the potential of multi-slice computed tomography (MSCT) as a tool for non-invasive temperature measurement. Materials and methods: Samples of water, 0.9% saline, sunflower oil and dilutions of (1:32, 1:64, 1:128) contrast agent (Iopromid 370, BayerSchering Pharma, Berlin) were heated in a plexiglass phantom. In a first set-up, samples of 0.9% saline solution were scanned at defined temperatures (25 degrees-75 degrees C; 5 degrees C intervals) using a clinical CT scanner. Scan parameters (tube current-time product, tube voltage, collimation, slice thickness) were systematically varied. In a second set-up samples of the different fluids (water, sunflower oil, contrast agent dilutions) were scanned using the following scan protocol: 250 mAs, 140 kV, 1.2 mm collimation, 9.6 mm slice thickness. CT numbers were measured in reconstructed axial images at the different temperatures. A regression analysis was performed to investigate the relationship between temperature and CT number. Results: Standard deviation of measured CT numbers decreased with increasing tube current-time product, increasing tube voltage, thicker collimation and higher slice thickness. Regression analysis showed an inverse relationship between temperature and CT number for all fluids with regression coefficients of -0.471 (0.9% saline), 0.447 (water), -0.679 (sunflower oil), -0.420 (contrast agent 1: 32), -0.414 (contrast agent 1: 64) and -0.441 (contrast agent 1: 128), respectively. Conclusion: Multi-slice computed tomography can depict thermal density expansion of different fluids. Based on these results the implementation of a temperature discrimination of several degrees C at a high spatial resolution is achievable.
引用
收藏
页码:359 / 365
页数:7
相关论文
共 50 条
  • [31] Coronary artery calcium score and non-invasive angiography with multi-slice computed tomography; Comparison to myocardial perfusion imaging in asymptomatic diabetics.
    Scholte, Arthur
    Schuijf, Joanne
    Kharagjitsingh, Antje
    Stokkel, Marcel
    Jukema, Wouter
    de Roos, Albert
    van der Wall, Ernst
    Bax, Jeroen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 183A - 183A
  • [32] Non-invasive evaluation with multi-slice computed tomography in suspected acute coronary syndrome: Plaque composition on MSCT versus coronary calcium score
    Henneman, Maureen M.
    Schuijf, Joanne D.
    Pundziute, Gabija
    van Werkhoven, Jaap M.
    van der Wall, Ernst E.
    Jukema, J. W.
    Schalij, Martin J.
    Bax, Jeroen J.
    CIRCULATION, 2007, 116 (16) : 692 - 692
  • [33] Which patients should be referred for non-invasive angiography with multi-slice CT?
    Bax, Jeroen J.
    Schuijf, Joanne D.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 114 (01) : 1 - 3
  • [34] Measurement of 3D spatial resolution in Multi-Slice Spiral Computed Tomography
    Fuchs, TOJ
    Krause, JU
    Kalender, WA
    PHYSICA MEDICA, 2001, 17 (03) : 129 - 134
  • [35] Non-invasive evaluation of coronary artery bypass grafts using 16-row multi-slice computed tomography with 188 ms temporal resolution
    Burgstahler, C
    Beek, T
    Kuettner, A
    Drosch, T
    Kopp, AF
    Heuschmid, M
    Claussen, CD
    Schroeder, S
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 106 (02) : 244 - 249
  • [36] Non-invasive coronary angiography: the clinical value of multi-slice computed tomography in the assessment of patients with prior coronary bypass surgeryEvaluating grafts and native vessels
    Helge von Kiedrowski
    Marcus Wiemer
    Krista Franzke
    Rainer Preuss
    Bernhard Vaske
    Thomas Butz
    Olaf Oldenburg
    Thomas Bitter
    Khalid Mahmood
    Wolfram Burchert
    Dieter Horstkotte
    Christoph Langer
    The International Journal of Cardiovascular Imaging, 2009, 25 : 161 - 170
  • [37] Non-invasive characterisation of coronary lesion morphology by multi-slice computed tomography: a promising new technology for risk stratification of patients with coronary artery disease
    Schroeder, S
    Kopp, AF
    Baumbach, A
    Kuettner, A
    Georg, C
    Ohnesorge, B
    Herdeg, C
    Claussen, CD
    Karsch, KR
    HEART, 2001, 85 (05) : 576 - 577
  • [38] Multi-slice quantum Computed Tomography system using a MHSP
    Carramate, L. F. N. D.
    Oliveira, C. A. B.
    Silva, A. L. M.
    da Silva, A. M.
    dos Santos, J. M. F.
    Veloso, J. F. C. A.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [39] Multi-slice computed tomography for diagnosis of combined thoracoabdominal injury
    Liu, Jun
    Yue, Weidong
    Du, Dingyuan
    CHINESE JOURNAL OF TRAUMATOLOGY, 2015, 18 (01) : 27 - 32
  • [40] Evaluation of intestinal tuberculosis by multi-slice computed tomography enterography
    Zhao, Jing
    Cui, Min-Yi
    Chan, Tao
    Mao, Ren
    Luo, Yanji
    Barua, Indira
    Chen, Minhu
    Li, Zi-Ping
    Feng, Shi-Ting
    BMC INFECTIOUS DISEASES, 2015, 15