A Quantitative Analysis of Factors Affecting the Dose Conversion From Pencil Beam (PB) to Monte Carlo (MC) in Lung SBRT Planning

被引:0
|
作者
Zheng, D. [1 ]
Zhu, X. [1 ]
Lin, C. [1 ]
Zhang, Q. [1 ]
Lei, Y. [1 ]
Wahl, A. O. [1 ]
Zhen, W. [1 ]
Zhou, S. M. [1 ]
机构
[1] Univ Nebraska Med Ctr, Omaha, NE USA
关键词
D O I
10.1016/j.ijrobp.2015.07.2033
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
3458
引用
收藏
页码:E581 / E582
页数:2
相关论文
共 50 条
  • [1] Target dose conversion modeling from pencil beam (PB) to Monte Carlo (MC) for lung SBRT
    Dandan Zheng
    Xiaofeng Zhu
    Qinghui Zhang
    Xiaoying Liang
    Weining Zhen
    Chi Lin
    Vivek Verma
    Shuo Wang
    Andrew Wahl
    Yu Lei
    Sumin Zhou
    Chi Zhang
    Radiation Oncology, 11
  • [2] Target dose conversion modeling from pencil beam (PB) to Monte Carlo (MC) for lung SBRT
    Zheng, Dandan
    Zhu, Xiaofeng
    Zhang, Qinghui
    Liang, Xiaoying
    Zhen, Weining
    Lin, Chi
    Verma, Vivek
    Wang, Shuo
    Wahl, Andrew
    Lei, Yu
    Zhou, Sumin
    Zhang, Chi
    RADIATION ONCOLOGY, 2016, 11
  • [3] Evaluation of the AAA Treatment Planning Algorithm for SBRT Lung Treatment: Comparison with Monte Carlo and Homogeneous Pencil Beam Dose Calculations
    Gete, Ermias
    Teke, Tony
    Kwa, William
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2012, 43 (01) : 26 - 33
  • [4] Dose to Proximal Bronchial Tree in Lung SBRT Treatments: Comparison of Pencil Beam and Monte Carlo Dose Distributions
    Altunbas, C.
    Miften, M.
    Stuhr, K.
    Gaspar, L.
    Kavanagh, B.
    MEDICAL PHYSICS, 2010, 37 (06) : 3276 - +
  • [5] Evaluating Pencil Beam Dose Algorithm in Lung with Monte Carlo
    Depauw, N.
    Seco, J.
    Adams, J.
    Panahandeh, H.
    Paganetti, H.
    Kooy, H.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [6] Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT
    Liu, Han
    Zhuang, Tingliang
    Stephans, Kevin
    Videtic, Gregory
    Raithel, Stephen
    Djemil, Toufik
    Xia, Ping
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (06): : 91 - 99
  • [7] Differences in Dose Calculation Between Pencil Beam and Monte Carlo Do Not Account for Local Failure in Lung SBRT: A Matched Pair Analysis
    Zhuang, T.
    Woody, N. M.
    Qi, P.
    Magnelli, A.
    Liu, H.
    Stephans, K. L.
    Videtic, G. M.
    Xia, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E600 - E600
  • [8] Comparison of Monte Carlo with pencil beam dosimetry for lung CyberKnife SBRT, correlation with local recurrence
    Ove, Roger
    Parker, Colbert A.
    Chilukuri, Madhu B.
    Russo, Suzanne M.
    JOURNAL OF RADIATION ONCOLOGY, 2015, 4 (03) : 257 - 263
  • [9] Experimental and Monte Carlo Investigation of Dose Calculation Accuracy for Lung SBRT Planning
    Rosenfield, J.
    Manohar, N.
    Yang, X.
    Dong, X.
    Elder, E.
    Higgins, K.
    Dhabaan, A.
    MEDICAL PHYSICS, 2017, 44 (06) : 2965 - 2965
  • [10] Dosimetric Evaluation of Centrally Located Lung Tumors: A Monte Carlo (MC) Study of Lung SBRT Planning
    Pokhrel, D.
    Badkul, R.
    Jiang, H.
    Saleh, H.
    Estes, C.
    Park, J.
    Kumar, P.
    Wang, F.
    MEDICAL PHYSICS, 2014, 41 (06) : 167 - 167