Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT

被引:13
|
作者
Liu, Han [1 ]
Zhuang, Tingliang [1 ]
Stephans, Kevin [1 ]
Videtic, Gregory [1 ]
Raithel, Stephen [1 ]
Djemil, Toufik [1 ]
Xia, Ping [1 ]
机构
[1] Cleveland Clin, Dept Radiat Oncol, Cleveland, OH 44195 USA
来源
关键词
lung SBRT; IMRT; dose calculation; Monte Carlo; pencil beam; BODY RADIATION-THERAPY; HYPOFRACTIONATED STEREOTACTIC RADIOTHERAPY; CLINICAL-EVALUATION; PHOTON BEAMS; CANCER; ALGORITHM; VERIFICATION; ENERGY; VMC;
D O I
10.1120/jacmp.v16i6.5514
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For patients with medically inoperable early-stage non-small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy, early treatment plans were based on a simpler dose calculation algorithm, the pencil beam (PB) calculation. Because these patients had the longest treatment follow-up, identifying dose differences between the PB calculated dose and Monte Carlo calculated dose is clinically important for understanding of treatment outcomes. Previous studies found significant dose differences between the PB dose calculation and more accurate dose calculation algorithms, such as convolution-based or Monte Carlo (MC), mostly for three-dimensional conformal radiotherapy (3D CRT) plans. The aim of this study is to investigate whether these observed dose differences also exist for intensity-modulated radiotherapy (IMRT) plans for both centrally and peripherally located tumors. Seventy patients (35 central and 35 peripheral) were retrospectively selected for this study. The clinical IMRT plans that were initially calculated with the PB algorithm were recalculated with the MC algorithm. Among these paired plans, dosimetric parameters were compared for the targets and critical organs. When compared to MC calculation, PB calculation overestimated doses to the planning target volumes (PTVs) of central and peripheral tumors with different magnitudes. The doses to 95% of the central and peripheral PTVs were overestimated by 9.7% +/- 5.6% and 12.0% +/- 7.3%, respectively. This dose overestimation did not affect doses to the critical organs, such as the spinal cord and lung. In conclusion, for NSCLC treated with IMRT, dose differences between the PB and MC calculations were different from that of 3D CRT. No significant dose differences in critical organs were observed between the two calculations.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 50 条
  • [1] Radiobiological and dosimetric impact of RayStation pencil beam and Monte Carlo algorithms on intensity-modulated proton therapy breast cancer plans
    Rana, Suresh
    Greco, Kevin
    Samuel, E. James Jebaseelan
    Bennouna, Jaafar
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (08): : 36 - 46
  • [2] Dose to Proximal Bronchial Tree in Lung SBRT Treatments: Comparison of Pencil Beam and Monte Carlo Dose Distributions
    Altunbas, C.
    Miften, M.
    Stuhr, K.
    Gaspar, L.
    Kavanagh, B.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3276 - +
  • [3] Target dose conversion modeling from pencil beam (PB) to Monte Carlo (MC) for lung SBRT
    Zheng, Dandan
    Zhu, Xiaofeng
    Zhang, Qinghui
    Liang, Xiaoying
    Zhen, Weining
    Lin, Chi
    Verma, Vivek
    Wang, Shuo
    Wahl, Andrew
    Lei, Yu
    Zhou, Sumin
    Zhang, Chi
    [J]. RADIATION ONCOLOGY, 2016, 11
  • [4] Target dose conversion modeling from pencil beam (PB) to Monte Carlo (MC) for lung SBRT
    Dandan Zheng
    Xiaofeng Zhu
    Qinghui Zhang
    Xiaoying Liang
    Weining Zhen
    Chi Lin
    Vivek Verma
    Shuo Wang
    Andrew Wahl
    Yu Lei
    Sumin Zhou
    Chi Zhang
    [J]. Radiation Oncology, 11
  • [5] Monte Carlo dose verification for intensity-modulated arc therapy
    Li, XA
    Ma, LJ
    Naqvi, S
    Shih, RP
    Yu, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (09): : 2269 - 2282
  • [6] Evaluating Pencil Beam Dose Algorithm in Lung with Monte Carlo
    Depauw, N.
    Seco, J.
    Adams, J.
    Panahandeh, H.
    Paganetti, H.
    Kooy, H.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [7] Differences in Dose Calculation Between Pencil Beam and Monte Carlo Do Not Account for Local Failure in Lung SBRT: A Matched Pair Analysis
    Zhuang, T.
    Woody, N. M.
    Qi, P.
    Magnelli, A.
    Liu, H.
    Stephans, K. L.
    Videtic, G. M.
    Xia, P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E600 - E600
  • [8] Relationships between Monte Carlo calculated dose parameters and lung densities in lung SBRT
    Tsang, Y.
    Duong, J.
    Jackson, G.
    DeSouza, R.
    Ko, K.
    Nariyangadu, P.
    Clark, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S582 - S583
  • [9] Optimization of intensity-modulated radiotherapy plans based on the equivalent uniform dose
    Wu, QW
    Mohan, R
    Niemierko, A
    Schmidt-Ullrich, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (01): : 224 - 235
  • [10] The impact of Monte Carlo dose calculations on intensity-modulated radiation therapy
    Siebers, JV
    Keall, PJ
    Mohan, R
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 205 - 210