Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT

被引:13
|
作者
Liu, Han [1 ]
Zhuang, Tingliang [1 ]
Stephans, Kevin [1 ]
Videtic, Gregory [1 ]
Raithel, Stephen [1 ]
Djemil, Toufik [1 ]
Xia, Ping [1 ]
机构
[1] Cleveland Clin, Dept Radiat Oncol, Cleveland, OH 44195 USA
来源
关键词
lung SBRT; IMRT; dose calculation; Monte Carlo; pencil beam; BODY RADIATION-THERAPY; HYPOFRACTIONATED STEREOTACTIC RADIOTHERAPY; CLINICAL-EVALUATION; PHOTON BEAMS; CANCER; ALGORITHM; VERIFICATION; ENERGY; VMC;
D O I
10.1120/jacmp.v16i6.5514
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For patients with medically inoperable early-stage non-small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy, early treatment plans were based on a simpler dose calculation algorithm, the pencil beam (PB) calculation. Because these patients had the longest treatment follow-up, identifying dose differences between the PB calculated dose and Monte Carlo calculated dose is clinically important for understanding of treatment outcomes. Previous studies found significant dose differences between the PB dose calculation and more accurate dose calculation algorithms, such as convolution-based or Monte Carlo (MC), mostly for three-dimensional conformal radiotherapy (3D CRT) plans. The aim of this study is to investigate whether these observed dose differences also exist for intensity-modulated radiotherapy (IMRT) plans for both centrally and peripherally located tumors. Seventy patients (35 central and 35 peripheral) were retrospectively selected for this study. The clinical IMRT plans that were initially calculated with the PB algorithm were recalculated with the MC algorithm. Among these paired plans, dosimetric parameters were compared for the targets and critical organs. When compared to MC calculation, PB calculation overestimated doses to the planning target volumes (PTVs) of central and peripheral tumors with different magnitudes. The doses to 95% of the central and peripheral PTVs were overestimated by 9.7% +/- 5.6% and 12.0% +/- 7.3%, respectively. This dose overestimation did not affect doses to the critical organs, such as the spinal cord and lung. In conclusion, for NSCLC treated with IMRT, dose differences between the PB and MC calculations were different from that of 3D CRT. No significant dose differences in critical organs were observed between the two calculations.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 50 条
  • [21] Respiratory Motion and Delivered Dose Accuracy for Gated Intensity-Modulated SBRT for Lung Cancer
    Yang, Y.
    Li, X.
    Li, T.
    Ding, C.
    Heron, D.
    Huq, M.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [22] Acceleration of dose calculations for intensity-modulated radiotherapy
    Siebers, JV
    Tong, SD
    Lauterbach, M
    Wu, QW
    Mohan, R
    MEDICAL PHYSICS, 2001, 28 (06) : 903 - 910
  • [23] Simplifying intensity-modulated radiotherapy plans with fewer beam angles for the treatment of oropharyngeal carcinoma
    Takamiya, Robert
    Missett, Brian
    Weinberg, Vivian
    Akazawa, Clayton
    Akazawa, Pam
    Zytkovicz, Andrea
    Bucci, Mary Kara
    Lee, Nancy
    Quivey, Jeanne
    Xia, Ping
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (02): : 26 - 36
  • [24] A pencil beam algorithm for intensity modulated proton therapy derived from Monte Carlo simulations
    Soukup, M
    Fippel, M
    Alber, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (21): : 5089 - 5104
  • [25] Monte Carlo calculated conceptus dose in brain radiotherapy
    Tzedakis, A
    Damilakis, J
    Stratakis, J
    Varveris, H
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S446 - S447
  • [26] Effectiveness of Intensity-modulated Radiotherapy for Lung Cancer
    Hsia, T. C.
    Tu, C. Y.
    Chen, H. J.
    Chien, C. R.
    CLINICAL ONCOLOGY, 2013, 25 (07) : 447 - 448
  • [27] Effect of the normalized prescription isodose line on the magnitude of Monte Carlo vs. pencil beam target dose differences for lung stereotactic body radiotherapy
    Zheng, Dandan
    Zhang, Qinghui
    Liang, Xiaoying
    Zhu, Xiaofeng
    Verma, Vivek
    Wang, Shuo
    Zhou, Sumin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 48 - 58
  • [28] Characterisation of dose in SBRT lung via Monte Carlo
    Rassiah, P.
    Fuss, M.
    Blough, M.
    Hussey, D.
    Lancaster, J.
    Papanikolaou, N.
    Salter, B.
    MEDICAL PHYSICS, 2006, 33 (06) : 2076 - 2076
  • [29] Dosimetric verification for intensity-modulated radiotherapy of thoracic cancers using experimental and Monte Carlo approaches
    Jang, Si Young
    Liu, H. Helen
    Wang, Xiaochun
    Vassiliev, Oleg N.
    Siebers, Jeffrey V.
    Dong, Lei
    Mohan, Radhe
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : 939 - 948
  • [30] Monte Carlo Finite-Size Pencil Beam Dose Calculation Engine for Accurate Radiotherapy
    Zheng, H.
    Wang, H.
    Cao, R.
    Song, J.
    He, T.
    Wu, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 2924 - 2924