A Quantitative Analysis of Factors Affecting the Dose Conversion From Pencil Beam (PB) to Monte Carlo (MC) in Lung SBRT Planning

被引:0
|
作者
Zheng, D. [1 ]
Zhu, X. [1 ]
Lin, C. [1 ]
Zhang, Q. [1 ]
Lei, Y. [1 ]
Wahl, A. O. [1 ]
Zhen, W. [1 ]
Zhou, S. M. [1 ]
机构
[1] Univ Nebraska Med Ctr, Omaha, NE USA
关键词
D O I
10.1016/j.ijrobp.2015.07.2033
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
3458
引用
收藏
页码:E581 / E582
页数:2
相关论文
共 50 条
  • [21] Dosimetric Effect of Implanted Hardware in Spine SBRT: Comparison of the Actual Planned Dose Using Pencil Beam Calculation to Monte Carlo
    Djemil, T.
    Ouzidane, M.
    Unal, S.
    Reddy, C. A.
    Angelov, L.
    Suh, J. H.
    Chao, S. T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S826 - S826
  • [22] LUNG SPARING AND TUMOR COVERAGE IN 4DCT LUNG PLANNING: A MONTE CARLO, PENCIL BEAM AND AAA COMPARISON
    Aarup, L. R.
    Zacharatou, C.
    Persson, G. F.
    Brink, C.
    Nahum, A. E.
    Specht, L.
    Nystrom, H.
    Korreman, S.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S251 - S251
  • [23] BED Vs. Local Control: Radiobiological Effect of Tumor Volume in Monte Carlo (MC) Lung SBRT Planning
    Pokhrel, D.
    Badkul, R.
    Jiang, H.
    Estes, C.
    Park, J.
    Kumar, P.
    Wang, F.
    MEDICAL PHYSICS, 2014, 41 (06) : 94 - 94
  • [24] PLANNING COMPARISON BETWEEN IPLAN RT DOSE MONTE CARLO AND PENCIL BEAM ALGORITHMS FOR HEAD AND NECK PATIENTS
    Harmsen-Jongerden, R.
    Smink, F.
    Bos, P.
    Petoukhova, A.
    Wiggenraad, R.
    van Santvoort, J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S585 - S585
  • [25] Pseudo Proton Radiography Beam Validation of Monte Carlo Dose Calculation in Two Pencil Beam Scanning Treatment Planning Systems
    Chang, C.
    Zhou, J.
    Yang, X.
    Dhabaan, A.
    Zhang, R.
    Liu, T.
    McDonald, M.
    Langen, K.
    Lin, L.
    MEDICAL PHYSICS, 2019, 46 (06) : E592 - E592
  • [26] Comparative Analysis of Pencil Beam and Monte Carlo Based Algorithms for Thoracic Spine Stereotactic Body Radiation Therapy (SBRT)
    Badkul, R.
    Jiang, H.
    Saleh, H.
    Wang, F.
    Chen, A.
    Lominska, C.
    MEDICAL PHYSICS, 2017, 44 (06) : 2965 - 2965
  • [27] Differences in dose calculation depending on the used algorithm: Comparison of dose distribution in the mediastinal region between Pencil Beam (PB), Collapsed Cone (CC) and Monte Carlo (MC) calculation algorithms
    Abo-Madyan, Y.
    Koeck, J.
    Stieler, F.
    Olms-Hofmann, S.
    Wenz, F.
    Lohr, F.
    Eich, H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 96 - 96
  • [28] PENCIL BEAM (PB), COLLAPSED CONE (CC) AND MONTE CARLO (MC) DOSE CALCULATION: DIFFERENCES IN DOSE DISTRIBUTION IN THE TREATMENT OF MEDIASTINAL HODGKIN LYMPHOMA (HL) AS A CONSEQUENCE OF USING DIFFERENT ALGORITHMS
    Abo-Madyan, Y.
    Koeck, J.
    Stieler, F.
    Olms-Hofmann, S.
    Wenz, F.
    Lohr, F.
    Eich, H.
    HAEMATOLOGICA, 2010, 95 : S46 - S46
  • [29] Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations
    Vanderstraeten, Barbara
    Reynaert, Nick
    Paelinck, Leen
    Madani, Indira
    De Wagter, Carlos
    De Gersem, Werner
    De Neve, Wilfried
    Thierens, Hubert
    MEDICAL PHYSICS, 2006, 33 (09) : 3149 - 3158
  • [30] Accuracy of Patient Dose Calculation in Proton Therapy of Lung Cancer: A Comparison of Monte Carlo and Pencil Beam Computations
    Mirkovic, D.
    Tit, U.
    Mohan, R.