The effect of postoperative positive end-expiratory pressure on postoperative bleeding after off-pump coronary artery bypass grafting

被引:1
|
作者
Yildiz, Yahya [1 ]
Salihoglu, Ece [1 ]
Celik, Sezai [1 ]
Ugurlucan, Murat [2 ]
Caglar, Ilker Murat [3 ]
Turhan-Caglar, Fatma Nihan [4 ]
Isik, Omer [1 ,5 ]
机构
[1] Med Hosp Camlica, Dept Anesthesiol & Reanimat, Istanbul, Turkey
[2] Duzce Ataturk State Hosp, Dept Cardiovasc Surg, Duzce, Turkey
[3] Bakirkoy Sadi Konuk Training & Res Hosp, Dept Cardiol, Istanbul, Turkey
[4] Samatya State Hosp, Dept Cardiol, Istanbul, Turkey
[5] Pendik Bolge Hosp, Dept Cardiovasc Surg, Istanbul, Turkey
关键词
off-pump coronary artery bypass grafting; positive end-expiratory pressure; bleeding; pleural effusion; pericardial effusion; ACUTE RESPIRATORY-DISTRESS; HEMODYNAMIC-CHANGES; LUNG RECRUITMENT; BLOOD; SURGERY; TRANSFUSION; FAILURE; COMPLICATIONS; MANAGEMENT; OPERATIONS;
D O I
10.5114/aoms.2014.46213
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: To compare postoperative prophylactic use of two positive end-expiratory pressure (PEEP) levels in order to prevent postoperative bleeding in patients undergoing off-pump coronary artery bypass grafting (CABG) surgery. Material and methods: Sixty patients undergoing an elective off-pump CABG operation were included in this prospective, nonrandomized clinical trial. Patients were divided into two groups as receiving either 5 cm H2O (group 1) or 8 cm H2O PEEP (group 2) after the operation until being extubated. Chest tube outputs, use of blood products and other fluids, postoperative hemoglobin levels, accumulation of pleural and pericardial fluid after the removal of chest tubes, and duration of hospital stay were recorded and compared. Results: Low- and high-pressure PEEP groups did not differ with regard to postoperative chest tube outputs, amounts of transfusions and crystalloid/colloid infusion requirements, or postoperative hemoglobin levels. However, low-pressure PEEP application was associated with significantly higher pleural (92 +/- 37 ml vs. 69 +/- 29 ml, p = 0.03) and pericardial fluid (17 +/- 5 ml vs. 14 +/- 6 ml, p = 0.04) accumulation. On the other hand, high-pressure PEEP application was associated with significantly longer duration of hospitalization (6.25 +/- 1.21 days vs. 5.25 +/- 0.91 days, p = 0.03). Conclusions: Prophylactic administration of postoperative PEEP levels of 8 cm H2O, although safe, does not seem to reduce chest-tube output or transfusion requirements in off-pump CABG when compared to the lower level of PEEP. Further studies with larger sample sizes are warranted to confirm the benefits and identify ideal levels of PEEP administration in this group of patients.
引用
收藏
页码:933 / 940
页数:8
相关论文
共 50 条
  • [41] Does tranexamic acid reduce bleeding after off-pump coronary artery bypass grafting?
    Mehr-Aein, A
    Madani-Civi, M
    ANESTHESIA AND ANALGESIA, 2004, 98 (04): : 83 - 83
  • [42] Relationship between pre-extubation positive end-expiratory pressure and oxygenation after coronary artery bypass grafting
    Lima, Reijane Oliveira
    Borges, Daniel Lago
    Goncalves Costa, Marina de Albuquerque
    Pereira Baldez, Thiago Eduardo
    Barbosa e Silva, Mayara Gabrielle
    Silva Sousa, Felipe Andre
    Soares, Milena de Oliveira
    Moreira Pinto, Jivago Gentil
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2015, 30 (04): : 443 - 448
  • [43] Recent unstable angina and off-pump coronary artery bypass grafting is not related to postoperative atrial fibrillation
    Wu, ZK
    Iivainen, T
    Pehkonen, E
    Laurikka, J
    Tarkka, MR
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2003, 37 (06) : 334 - 339
  • [44] Increased early postoperative morbidity with off-pump coronary artery bypass grafting surgery in patients with diabetes
    Vermes, E
    Demaria, RG
    Martineau, R
    Cartier, R
    Pellerin, M
    Hébert, Y
    Bouchard, D
    Pagé, P
    Carrier, M
    Perrault, LP
    CANADIAN JOURNAL OF CARDIOLOGY, 2004, 20 (14) : 1461 - 1465
  • [45] Twenty-Year Experience With Off-Pump Coronary Artery Bypass Grafting and Early Postoperative Angiography
    Kim, Ki-Bong
    Choi, Jae Woong
    Oh, Se Jin
    Hwang, Ho Young
    Kim, Jun Sung
    Choi, Jae-Sung
    Lim, Cheong
    ANNALS OF THORACIC SURGERY, 2020, 109 (04): : 1112 - 1119
  • [46] Coronary artery and graft spasm after off-pump coronary artery bypass grafting
    Fukui T.
    Takanashi S.
    Hosoda Y.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2005, 53 (2): : 109 - 113
  • [47] On-pump and off-pump coronary artery bypass grafting
    Shekar, PS
    CIRCULATION, 2006, 113 (04) : E51 - E52
  • [48] Stunned myocardium after off-pump coronary artery bypass grafting
    Grubitzsch, H
    Ansorge, K
    Wollert, HG
    Eckel, L
    ANNALS OF THORACIC SURGERY, 2001, 71 (01): : 352 - 355
  • [49] Impact of off-pump coronary artery bypass surgery on postoperative bleeding: Current best available evidence
    Guru, V
    Fremes, SE
    JOURNAL OF CARDIAC SURGERY, 2006, 21 (01) : 42 - 43
  • [50] Outcomes After Off-Pump Reoperative Coronary Artery Bypass Grafting
    Morris, Cullen D.
    Puskas, John D.
    Pusca, Sorin V.
    Lattouf, Omar M.
    Cooper, William A.
    Vassiliades, Thomas A.
    Chen, Edward P.
    Thourani, Vinod H.
    Kilgo, Patrick D.
    Guyton, Robert A.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2007, 2 (01) : 29 - 32