The effect of postoperative positive end-expiratory pressure on postoperative bleeding after off-pump coronary artery bypass grafting

被引:1
|
作者
Yildiz, Yahya [1 ]
Salihoglu, Ece [1 ]
Celik, Sezai [1 ]
Ugurlucan, Murat [2 ]
Caglar, Ilker Murat [3 ]
Turhan-Caglar, Fatma Nihan [4 ]
Isik, Omer [1 ,5 ]
机构
[1] Med Hosp Camlica, Dept Anesthesiol & Reanimat, Istanbul, Turkey
[2] Duzce Ataturk State Hosp, Dept Cardiovasc Surg, Duzce, Turkey
[3] Bakirkoy Sadi Konuk Training & Res Hosp, Dept Cardiol, Istanbul, Turkey
[4] Samatya State Hosp, Dept Cardiol, Istanbul, Turkey
[5] Pendik Bolge Hosp, Dept Cardiovasc Surg, Istanbul, Turkey
关键词
off-pump coronary artery bypass grafting; positive end-expiratory pressure; bleeding; pleural effusion; pericardial effusion; ACUTE RESPIRATORY-DISTRESS; HEMODYNAMIC-CHANGES; LUNG RECRUITMENT; BLOOD; SURGERY; TRANSFUSION; FAILURE; COMPLICATIONS; MANAGEMENT; OPERATIONS;
D O I
10.5114/aoms.2014.46213
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: To compare postoperative prophylactic use of two positive end-expiratory pressure (PEEP) levels in order to prevent postoperative bleeding in patients undergoing off-pump coronary artery bypass grafting (CABG) surgery. Material and methods: Sixty patients undergoing an elective off-pump CABG operation were included in this prospective, nonrandomized clinical trial. Patients were divided into two groups as receiving either 5 cm H2O (group 1) or 8 cm H2O PEEP (group 2) after the operation until being extubated. Chest tube outputs, use of blood products and other fluids, postoperative hemoglobin levels, accumulation of pleural and pericardial fluid after the removal of chest tubes, and duration of hospital stay were recorded and compared. Results: Low- and high-pressure PEEP groups did not differ with regard to postoperative chest tube outputs, amounts of transfusions and crystalloid/colloid infusion requirements, or postoperative hemoglobin levels. However, low-pressure PEEP application was associated with significantly higher pleural (92 +/- 37 ml vs. 69 +/- 29 ml, p = 0.03) and pericardial fluid (17 +/- 5 ml vs. 14 +/- 6 ml, p = 0.04) accumulation. On the other hand, high-pressure PEEP application was associated with significantly longer duration of hospitalization (6.25 +/- 1.21 days vs. 5.25 +/- 0.91 days, p = 0.03). Conclusions: Prophylactic administration of postoperative PEEP levels of 8 cm H2O, although safe, does not seem to reduce chest-tube output or transfusion requirements in off-pump CABG when compared to the lower level of PEEP. Further studies with larger sample sizes are warranted to confirm the benefits and identify ideal levels of PEEP administration in this group of patients.
引用
收藏
页码:933 / 940
页数:8
相关论文
共 50 条
  • [21] Tranexamic acid reduces bleeding after off-pump coronary artery bypass grafting
    Jares, M
    Vanek, T
    Straka, Z
    Brucek, P
    JOURNAL OF CARDIOVASCULAR SURGERY, 2003, 44 (02): : 205 - 208
  • [22] Nomogram for predicting major bleeding after off-pump coronary artery bypass grafting
    Jianqin Zhu
    Zhenjun Wu
    Guiming Huang
    Yuting Zhong
    Cheng Peng
    Journal of Cardiothoracic Surgery, 19
  • [23] The effects of atorvastatin on the occurrence of postoperative atrial fibrillation after off-pump coronary artery bypass grafting surgery
    Song, Young Bin
    On, Young Keun
    Kim, Jun Hyung
    Shin, Dae-Hee
    Kim, June Soo
    Sung, Jidong
    Lee, Sang Hoon
    Kim, Wook Sung
    Lee, Young Tak
    AMERICAN HEART JOURNAL, 2008, 156 (02)
  • [24] Positive end-expiratory pressure after uncomplicated coronary artery bypass grafting: a two-edge sword
    Villar, J.
    Kacmarek, R. M.
    MINERVA ANESTESIOLOGICA, 2012, 78 (07) : 743 - 745
  • [25] Impact of vasopressin use for postoperative atrial fibrillation in off-pump coronary artery bypass grafting
    Yamane, Kochi
    Fujii, Tasuku
    Aoyama, Tadashi
    Nonogaki, Mikio
    Nishiwaki, Kimitoshi
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2024, 86 (04) : 645 - 654
  • [26] Blood group as a novel predictor of postoperative atrial fibrillation after off-pump coronary artery bypass grafting
    Donmez, Ibrahim
    Muduroglu, Ayhan
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2023, 69 (09):
  • [27] Coronary artery spasm after off-pump coronary artery bypass grafting
    Lin, Chih-Yuan
    Weng, Zen-Chung
    Loh, Shih-Hurng
    Hong, Gou-Jieng
    Tsai, Chien-Sung
    ANZ JOURNAL OF SURGERY, 2007, 77 (03) : 126 - 129
  • [28] Postoperative stroke after off-pump versus on-pump coronary artery bypass surgery
    Biancari, Fausto
    Mosorin, Martti
    Rasinaho, Elsi
    Lahtinen, Jarmo
    Heikkinen, Jouni
    Niemela, Eija
    Anttila, Vesa
    Lepojarvi, Martti
    Juvonen, Tatu
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (01): : 169 - 173
  • [29] Off-pump coronary artery bypass grafting
    Abu-Omar, Y
    Taggart, DP
    LANCET, 2002, 360 (9329): : 327 - 329
  • [30] Paraplegia After Off-Pump Coronary Artery Bypass Grafting
    Miranda, Matheus
    Hossne, Nelson Americo, Jr.
    de Vilela, Andre Telis
    Buffolo, Enio
    ANNALS OF THORACIC SURGERY, 2014, 97 (01): : 326 - 327