Comparison of three two-dimensional echocardiographic methods of assessing left ventricular size in Doberman Pinschers*

被引:2
|
作者
Kruckman, L. [1 ]
Fries, R. C. [1 ]
Kadotani, S. [1 ]
Stack, J. P. [1 ]
Wallace, L. G. [1 ]
机构
[1] Univ Illinois, Dept Vet Clin Med, 1008 W Hazelwood Dr, Urbana, IL 61801 USA
关键词
Cardiovascular; Ultrasound; Canine; Anatomic M-mode; M-MODE ECHOCARDIOGRAPHY; DILATED CARDIOMYOPATHY; EFFICACY;
D O I
10.1016/j.jvc.2021.05.011
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Introduction: Compare three methods of obtaining linear left ventricular dimensions within the same Doberman Pinscher (DP). Animals: One hundred and thirty-nine client-owned DP. Materials and Methods: Linear left ventricular dimensions were measured using two-dimensional short-axis (Sx-2D), motion-mode short-axis (Sx-MM), and motionmode long-axis (Lx-MM) methods, then left ventricular volumes were obtained using monoplane Simpson's method of discs (SMOD). A Friedman test with Dunn's multiple comparisons was used to compare differences between methods. Bias and correlation were evaluated via Bland-Altman and Spearman's correlation. Sensitivity and specificity for diagnosing occult dilated cardiomyopathy (DCM) compared to SMOD were determined. Coefficients of variation (CVs) were calculated for intra- and inter-observer measurement variability. Results: There were significant differences between all linear dimensions in diastole and systole. Short-axis 2D measurements had significant bias compared with Sx-MM (diastole +1.19 mm, systole +1.65 mm) and Lx-MM (diastole +4.36 mm, systole +3.87 mm) as did Sx-MM compared with Lx-MM (diastole +3.17 mm, systole +2.22 mm). All linear dimensions had a moderate positive correlation with SMOD. The sensitivity and specificity of linear measurements to detect DCM were: Sx-2D (sensitivity 72.0%, specificity 88.5%), Sx-MM (sensitivity 52.0%, specificity 92.0%), and Lx-MM (sensitivity 37.5%, specificity 99.1%). All methods had acceptably low CV for intra-and inter-observer measurement variability. Conclusions: Results of this study suggest that linear measurements are repeatable and correlate with reference standard; however, there is a significant bias between measurements, and they should not be used interchangeably. 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:110 / 118
页数:9
相关论文
共 50 条
  • [21] EFFECT OF LEFT-VENTRICULAR HYPERTROPHY ON TWO-DIMENSIONAL ECHOCARDIOGRAPHIC EVALUATION OF INFARCT SIZE AND RISK AREA IN DOGS
    PANDIAN, NG
    KOYANAGI, S
    SKORTON, DJ
    COLLINS, S
    EASTHAM, CL
    MARCUS, ML
    KERBER, RE
    CLINICAL RESEARCH, 1981, 29 (04): : A697 - A697
  • [22] EFFECT OF LEFT-VENTRICULAR HYPERTROPHY ON TWO-DIMENSIONAL ECHOCARDIOGRAPHIC EVALUATION OF INFARCT SIZE AND RISK AREA IN DOGS
    PANDIAN, N
    KOYANAGI, S
    SKORTON, D
    COLLINS, S
    EASTHAM, C
    MARCUS, ML
    KERBER, R
    CIRCULATION, 1981, 64 (04) : 204 - 204
  • [23] Left ventricular ejection fraction in patients with normal and distorted left ventricular shape by three-dimensional echocardiographic methods: A comparison with radionuclide angiography
    Nosir, YFM
    Salustri, A
    Kasprzak, JD
    Breburda, CS
    Ten Cate, FJ
    Roelandt, JRTC
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (06) : 620 - 630
  • [24] Comparison of two-dimensional echocardiographic measurements of the left atrium in healthy dogs
    Hetyey, C
    Vörös, K
    Reiczigel, J
    ACTA VETERINARIA HUNGARICA, 2005, 53 (01) : 23 - 33
  • [25] Two-dimensional transthoracic contrast echocardiographic assessment of metastatic left ventricular tumors
    Yelamanchili, P
    Wanat, FE
    Knezevic, D
    Nanda, NC
    Patel, V
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (03): : 248 - 250
  • [26] IMPROVED TWO-DIMENSIONAL ECHOCARDIOGRAPHIC TECHNIQUE FOR LEFT-VENTRICULAR ANEURYSM DETECTION
    AMON, KW
    CRAWFORD, MH
    JOURNAL OF CLINICAL ULTRASOUND, 1982, 10 (06) : 261 - 263
  • [27] AORTICO LEFT-VENTRICULAR TUNNEL - TWO-DIMENSIONAL ECHOCARDIOGRAPHIC AND ANGIOCARDIOGRAPHIC FEATURES
    WU, JR
    HUANG, TY
    CHEN, YF
    LIN, YT
    ROAN, HR
    AMERICAN HEART JOURNAL, 1989, 117 (03) : 697 - 699
  • [28] Comparison of two-dimensional and three-dimensional echocardiographic strain in children with CHD
    Wisotzkey, Bethany L.
    Soriano, Brian D.
    Buddhe, Sujatha
    CARDIOLOGY IN THE YOUNG, 2017, 27 (08) : 1557 - 1565
  • [29] TWO-DIMENSIONAL ECHOCARDIOGRAPHIC EVALUATION OF RIGHT VENTRICULAR EJECTION FRACTION - COMPARISON BETWEEN 3 DIFFERENT METHODS
    VITOLO, E
    CASTINI, D
    COLOMBO, A
    CARINI, L
    DECEGLIA, S
    TAROLO, GL
    BOCCOLARI, S
    MANA, O
    ACTA CARDIOLOGICA, 1988, 43 (04) : 469 - 480
  • [30] TWO-DIMENSIONAL ECHOCARDIOGRAPHIC ESTIMATION OF THE INFARCT SIZE
    UEDA, K
    KOBORI, Y
    SANO, Y
    KAJIWARA, S
    SHIRAI, T
    HOMMA, S
    KUWAKI, K
    INOUE, K
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1981, 45 (08): : 879 - 879