In-core dosimetry for the validation of neutron spectra in the CROCUS reactor

被引:0
|
作者
Jiang, Y. [1 ,2 ,3 ]
Laureau, A. [1 ,2 ]
Lamirand, V [1 ,2 ,4 ]
Frajtag, P. [1 ,2 ]
Pautz, A. [1 ,2 ,5 ]
机构
[1] Ecole Polytech Fed Lausanne EPFL, Lausanne, Switzerland
[2] Ecole Polytech Fed Lausanne, Lab Reactor Phys & Syst Behav, CH-1015 Lausanne, Switzerland
[3] French Atom Energy Commiss, Expt Phys Serv, F-13108 St Paul Les Durance, France
[4] Paul Scherrer Inst, Lab Reactor Phys & Thermal Hydraul, CH-5232 Villigen, Switzerland
[5] Paul Scherrer Inst, Nucl Energy & Safety Res Div, CH-5232 Villigen, Switzerland
关键词
Neutron spectrum measurement; in-core dosimetry; gamma spectrometry; spectrum unfolding;
D O I
10.1051/epjconf/202022504021
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The present article describes the preliminary validation study of simulated in-core and reflector n eutron spectra in preparation of oncoming experimental programs in the zero-power reactor CROCUS at EPFL. For this purpose, a set of activation foils were irradiated at three characteristic positions in the CROCUS reactor, and the subsequent activities were analyzed via gamma spectrometry. The experimental setup was then modeled with the Monte Carlo neutron transport code Serpent2 and associated with an analysis tool to include the effect of the reactor power history during experiments. The comparison of calculated and measured reaction rates (C/E) indicates a general consistency (at 2 sigma) between calculated and measured spectra. However, offsets of C/E values were observed in (n,gamma) reactions, up to 18% for In-115 and 8% for Cu-63 dosimeters. This could be caused by an unexpected isotopic composition, uncertainties in nuclear data, or the spectrometry analysis. In addition, a 100-groups spectrum unfolding was performed using the experimentally determined reaction rates and the Serpent2 spectra as the prior knowledge. The unfolded spectra were mainly adjusted in the thermal and fast ranges, while few modifications were made in the epithermal region due to the low contribution of epithermal neutrons in activation processes. Moreover, within energy groups where the capture reactions show resonant behavior, flux depletion (up to 38% as compared to the prior spectra) is observed due to the absence of self-shielding effect in the unfolding process. For this purpose, an unfolding method based on energy groups weighting is developed and tested.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Developing and testing a miniature fiber-coupled scintillator for in-core neutron counting in CROCUS
    Vitullo, Fanny
    Lamirand, Vincent
    Mosset, Jean-Baptiste
    Frajtag, Pavel
    Pakari, Oskari
    Perret, Gregory
    Pautz, Andreas
    ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA 2019), 2020, 225
  • [2] Validation of the neutron and gamma fields in the JS']JSI TRIGA reactor using in-core fission and ionization chambers
    Zerovnik, Gasper
    Kaiba, Tanja
    Radulovic, Vladimir
    Jazbec, Anze
    Rupnik, Sebastjan
    Barbot, Loic
    Fourmentel, Damien
    Snoj, Luka
    APPLIED RADIATION AND ISOTOPES, 2015, 96 : 27 - 35
  • [3] NEUTRON DOSIMETRY AT BEAM PORT OF A TRIGA CORE REACTOR
    BEACH, JL
    DOUPLE, EB
    RADIATION RESEARCH, 1974, 59 (01) : 226 - 227
  • [4] A mm3 Fiber-Coupled Scintillator for In-Core Thermal Neutron Detection in CROCUS
    Vitullo, Fanny
    Lamirand, Vincent
    Mosset, Jean-Baptiste
    Frajtag, Pavel
    Pakari, Oskari
    Perret, Gregory
    Pautz, Andreas
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (04) : 625 - 635
  • [5] Development of an inconel self powered neutron detector for in-core reactor monitoring
    Alex, M.
    Ghodgaonkar, M. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (01): : 127 - 132
  • [6] VALIDATION OF IN-CORE MEASUREMENTS
    Machek, Jindrich
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 6, 2014,
  • [7] IN-CORE NEUTRON-DETECTOR BEHAVIOR DURING REACTOR TRANSIENT OPERATION
    BOCK, H
    NUCLEAR INSTRUMENTS & METHODS, 1975, 125 (02): : 327 - 329
  • [8] IN-CORE THERMIONIC REACTOR (ITR)
    GROSS, F
    LANGPAPE, R
    EINFELD, K
    SCHON, T
    BUDNICK, D
    JANNER, K
    KERNTECHNIK, 1969, 11 (07) : 381 - &
  • [9] IN-CORE NEUTRON FLUX INSTRUMENTATION
    FORSTER, JJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1965, NS12 (06) : 8 - &
  • [10] IN-CORE NEUTRON FLUX INSTRUMENTATION
    FORSTER, J
    IEEE SPECTRUM, 1965, 2 (03) : 74 - &